Gamma-ray Observations Under Bright Moonlight with VERITAS
S. Archambault, A. Archer, W. Benbow, R. Bird, E. Bourbeau, A. Bouvier, M. Buchovecky, V. Bugaev, J. V Cardenzana, M. Cerruti, L. Ciupik, M. P. Connolly, W. Cui… 展开作者
S. Archambault, A. Archer, W. Benbow, R. Bird, E. Bourbeau, A. Bouvier, M. Buchovecky, V. Bugaev, J. V Cardenzana, M. Cerruti, L. Ciupik, M. P. Connolly, W. Cui, M. K. Daniel, M. Errando, A. Falcone, Q. Feng, J. P. Finley, H. Fleischhack, L. Fortson, A. Furniss, G. H. Gillanders, S. Griffin, D. Hanna, O. Hervet, J. Holder, G. Hughes, T. B. Humensky, M. Hütten, C. A. Johnson, P. Kaaret, P. Kar, M. Kertzman, D. Kieda, M. Krause, M. J. Lang, G. Maier, S. McArthur, P. Moriarty, R. Mukherjee, D. Nieto, S. O'Brien, R. A. Ong, A. N. Otte, N. Park, M. Pohl, A. Popkow, E. Pueschel, J. Quinn, K. Ragan, P. T. Reynolds, G. T. Richards, E. Roache, C. Rulten, I. Sadeh, G. H. Sembroski, K. Shahinyan, D. Staszak, I. Telezhinsky, S. Trepanier, S. P. Wakely, A. Weinstein, P. Wilcox, D. A. Williams, B. Zitzer
Imaging atmospheric Cherenkov telescopes (IACTs) are equipped with sensitive photomultiplier tube (PMT) cameras. Exposure to high levels of background illumination degrades the efficiency of and potentially destroys these photo-detectors over time, so IACTs cannot be operated in the same configuration in the presence of bright moonlight as under dark skies. Since September 2012, observations have been carried out with the VERITAS IACTs under bright moonlight (defined as about three times the night-sky-background (NSB) of a dark extragalactic field, typically occurring when Moon illumination > 35%) in two observing modes, firstly by reducing the voltage applied to the PMTs and, secondly, with the addition of ultra-violet (UV) bandpass filters to the cameras. This has allowed observations at up to about 30 times previous NSB levels (around 80% Moon illumination), resulting in 30% more observing time between the two modes over the course of a year. These additional observations have already allowed for the detection of a flare from the 1ES 1727+502 and for an observing program targeting a measurement of the cosmic-ray positron fraction. We provide details of these new observing modes and their performance relative to the standard VERITAS observations.
A New Mirror Alignment System for the VERITAS Telescopes
用于TeV能量的地基伽马射线天文学的成像大气切伦科夫望远镜(IACT)使用面积约为100 m $^2$的反射器作为其主要光学元件。这些镶嵌的反射器包括安装在空间框架上的数百个镜面,以合理的成本实现这种大面积。为了获得足够质量的反射表面,必须使用称为对准的程序来精确地定向每个面。我们在这里描述的对准系统,它使用数字(CCD)相机放置在光学系统的焦点,面对反射器。当望远镜扫描一个以明亮恒星方向为中心的网格点时,相机会获得一系列反射器的图像。当望远镜直接指向恒星时,正确对准的小平面最亮,而当恒星和望远镜指向方向之间的角度是小平面未对准角度的两倍时,未对准的小平面最亮。来自该扫描的数据可用于计算对准每个面所需的调整。我们已经构建了这样一个系统,并在三个VERITAS IACT上进行了测试。利用该系统,望远镜的光学点扩散函数可缩窄30%以上。我们在这里介绍的系统和结果从最初的使用。
The University of Melbourne(墨尔本大学);Australian Astronomical Optics, Macquarie University(澳大利亚天文光学,麦考瑞大学);Macquarie University(麦考瑞大学);Astrophysics and Space Technologies Research Centre, Macquarie University(天体物理与空间技术中心,麦考瑞大学);Ansys(安sys)
Mock Observations for the CSST Mission: Main Surveys--the Stray Light
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences(中国科学院长春光学精密机械与物理研究所);University of Chinese Academy of Sciences(中国科学院大学);Shanghai Astronomical Observatory(上海天文台);National Astronomical Observatories, Chinese Academy of Sciences(中国科学院国家天文台);Purple Mountain Observatory, Chinese Academy of Sciences(中国科学院紫金山天文台)