The EBEX Collaboration, Asad Aboobaker, Peter Ade, Derek Araujo, François Aubin, Carlo Baccigalupi, Chaoyun Bao, Daniel Chapman, Joy Didier, Matt Dobbs, Will Grainger, Shaul Hanany, Kyle Helson, Seth Hillbrand, Johannes Hubmayr, Andrew Jaffe, Bradley Johnson, Terry Jones, Jeff Klein, Andrei Korotkov, Adrian Lee, Lorne Levinson, Michele Limon, Kevin MacDermid, Amber D. Miller, Michael Milligan, Lorenzo Moncelsi, Enzo Pascale, Kate Raach, Britt Reichborn-Kjennerud, Ilan Sagiv, Carole Tucker, Gregory S. Tucker, Benjamin Westbrook, Karl Young, Kyle Zilic

摘要:

E和B实验(EBEX)是一个长时间的球载仪器,旨在测量宇宙微波背景(CMB)辐射的偏振。EBEX是第一个球载仪器,实现了一个千像素阵列的过渡边缘传感器(TES)测辐射热探测器和第一个CMB实验,使用数字版本的频域复用系统的TES阵列的读数。扫描策略依赖于40 s峰-峰恒定速度方位扫描。我们讨论了这些新技术和扫描策略对有效载荷设计和操作的独特要求。我们描述了实施的解决方案,包括开发一个电源系统,旨在提供总的至少2.3千瓦,一个冷却系统,消耗590 W的探测器的读出系统,软件管理和处理数据的千像素阵列,和专门的姿态重建软件。我们目前的飞行性能数据显示无故障管理的TES阵列,足够的电源和冷却的读出电子设备,和约束的姿态重建误差,使假B模式,他们诱导小于10%的CMB B模式功率谱与$r=0.05$。

英文摘要:

The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilo-pixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilo-pixel array, and specialized attitude reconstruction software. We present flight performance data showing faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of CMB B-mode power spectrum with $r=0.05$.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑