arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1702.02743physics.med-phcs.CV
收藏

将信号行为的先验知识结合到重建中以加速MR扩散数据的采集

Incorporation of prior knowledge of the signal behavior into the reconstruction to accelerate the acquisition of MR diffusion data

Universidad Carlos III de Madrid(马德里卡洛斯三世大学);Instituto de Investigación Sanitaria Gregorio Marañón(格雷戈里奥·马拉尼翁健康研究所);INSA-Lyon(里昂国立应用科学学院);Université Claude Bernard Lyon 1(里昂第一大学);UJM-Saint Etienne(圣埃蒂安让·莫内大学);CNRS(法国国家科学研究中心);Inserm(法国国家健康与医学研究院);CREATIS(CREATIS 医学影像研究中心);Centro de Investigación en Red de Salud Mental(心理健康网络研究中心)

Juan F P J Abascal, Manuel Desco, Juan Parra-Robles

摘要:

使用超极化气体的扩散MRI测量通常在患者屏气期间采集,这在可实现的图像分辨率、肺部覆盖范围和b值数量之间产生折衷。在这项工作中,我们提出了一种新的方法,通过在空间和b值维度上欠采样来加速MR扩散数据的采集,这要归功于将有关信号衰减的知识纳入重建(SIDER)。通过评估SIDER对通气图像恢复和估计平均肺泡尺寸(MAD)的影响,将其与全变差(TV)重建进行比较。通过回顾性欠采样正常志愿者和COPD患者(n=8)的扩散数据集,对x2和x10之间的加速因子进行评估。对于等于或大于x5的加速因子,TV导致大的误差和伪影。SIDER改进了电视,提出更低的错误和MAD直方图更接近那些从完全采样的数据获得的加速度因子高达x10。SIDER在所有加速因子下都保持了图像质量,但图像略微平滑,并且在x10时丢失了一些细节。总之,我们已经开发并验证了一种用于肺部MRI成像的新型压缩感知方法,并实现了高加速因子,可用于增加屏气期间采集的数据量。这种方法有望提高估计肺微结构尺寸的准确性,并扩大了用MRI研究肺部疾病的可能性。

英文摘要:

Diffusion MRI measurements using hyperpolarized gases are generally acquired during patient breath hold, which yields a compromise between achievable image resolution, lung coverage and number of b-values. In this work, we propose a novel method that accelerates the acquisition of MR diffusion data by undersampling in both spatial and b-value dimensions, thanks to incorporating knowledge about the signal decay into the reconstruction (SIDER). SIDER is compared to total variation (TV) reconstruction by assessing their effect on both the recovery of ventilation images and estimated mean alveolar dimensions (MAD). Both methods are assessed by retrospectively undersampling diffusion datasets of normal volunteers and COPD patients (n=8) for acceleration factors between x2 and x10. TV led to large errors and artefacts for acceleration factors equal or larger than x5. SIDER improved TV, presenting lower errors and histograms of MAD closer to those obtained from fully sampled data for accelerations factors up to x10. SIDER preserved image quality at all acceleration factors but images were slightly smoothed and some details were lost at x10. In conclusion, we have developed and validated a novel compressed sensing method for lung MRI imaging and achieved high acceleration factors, which can be used to increase the amount of data acquired during a breath-hold. This methodology is expected to improve the accuracy of estimated lung microstructure dimensions and widen the possibilities of studying lung diseases with MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑