We propose an innovative strategy to discriminate between two coherent states affected by either uniform or gaussian phase noise. The strategy is based on a homodyne-like detection scheme with photon-number-resolving detectors in the regime of low-intensity local oscillator. The experimental implementation of the detection scheme involves two hybrid photodetectors, whose outputs are used in post processing to calculate the shot-by-shot photon-number difference. The performance of this strategy is quantified in terms of the error probability in discriminating the noisy coherent signals as a function of the characteristic noise parameters.
We investigate quantum measurement strategies capable of discriminating two coherent states probabilistically with significantly smaller error probabilities than can be obtained using non- probabilistic state discrimination. We apply a postselection strategy to the measurement data of a homodyne detector as well as a photon number resolving detector in order to lower the error probability. We compare the two different receivers with an optimal intermediate measurement scheme where the error rate is minimized for a fixed rate of inconclusive results. The photon number resolving (PNR) receiver i…
Fast and accurate measurement is a highly desirable, if not vital, feature of quantum computing architectures. In this work we investigate the usefulness of adaptive measurements in improving the speed and accuracy of qubit measurement. We examine a particular class of quantum computing architectures, ones based on qubits coupled to well controlled harmonic oscillator modes (reminiscent of cavity-QED), where adaptive schemes for measurement are particularly appropriate. In such architectures, qubit measurement is equivalent to phase discrimination for a mode of the electromagnetic field, and w…
We address the limit of the Gaussian operations and classical communication in the problem of quantum state discrimination. We show that the optimal Gaussian strategy for the discrimination of the binary phase shift keyed (BPSK) coherent signal is a simple homodyne detection. We also propose practical near-optimal quantum receivers that beat the BPSK homodyne limit in all areas of the signal power. Our scheme is simple and does not require realtime electrical feedback.
We experimentally demonstrate a new measurement scheme for the discrimination of two coherent states. The measurement scheme is based on a displacement operation followed by a photon number resolving detector, and we show that it outperforms the standard homodyne detector which we, in addition, proof to be optimal within all Gaussian operations including conditional dynamics. We also show that the non-Gaussian detector is superior to the homodyne detector in a continuous variable quantum key distribution scheme.
We investigate the performance of a Kennedy receiver, which is known as a beneficial tool in optical coherent communications, to the quantum state discrimination of the two superpositions of vacuum and single photon states corresponding to the $\hatσ_x$ eigenstates in the single-rail encoding of photonic qubits. We experimentally characterize the Kennedy receiver in vacuum-single photon two-dimensional space using quantum detector tomography and evaluate the achievable discrimination error probability from the reconstructed measurement operators. We furthermore derive the minimum error rate ob…
We address extended systems interacting with classical fluctuating environments and analyze the use of quantum probes to discriminate local noise, described by independent fluctuating fields, from common noise, corresponding to the interaction with a common one. In particular, we consider a bipartite system made of two non interacting harmonic oscillators and assess discrimination strategies based on homodyne detection, comparing their performances with the ultimate bounds on the error probabilities of quantum-limited measurements. We analyze in details the use of Gaussian probes, with emphasi…
We address binary optical communication channels based on phase-shift keyed coherent signals in the presence of phase diffusion. We prove theoretically and demonstrate experimentally that a discrimination strategy based on homodyne detection is robust against this kind of noise for any value of the channel energy. Moreover, we find that homodyne receiver beats the performance of Kennedy receiver as the signal energy increases, and achieves the Helstrom bound in the limit of large noise.
We demonstrate a die-level balanced homodyne detector with a high quantum-to-classical noise clearance of 19.1dB over 3GHz bandwidth. We evaluate this receiver as a high-quality entropy source for random number generation at >10Gb/s and prove the functional integration of a classical 10Gb/s duobinary communication channel.
The effect of the detector electronic noise in an optical homodyne tomography experiment is shown to be equivalent to an optical loss if the detector is calibrated by measuring the quadrature noise of the vacuum state. An explicit relation between the electronic noise level and the equivalent optical efficiency is obtained and confirmed in an experiment with a narrowband squeezed vacuum source operating at an atomic rubidium wavelength.
The optimal discrimination of non-orthogonal quantum states with minimum error probability is a fundamental task in quantum measurement theory as well as an important primitive in optical communication. In this work, we propose and experimentally realize a new and simple quantum measurement strategy capable of discriminating two coherent states with smaller error probabilities than can be obtained using the standard measurement devices; the Kennedy receiver and the homodyne receiver.
Homodyne tomography provides a way for measuring generic field-operators. Here we analyze the determination of the most relevant quantities: intensity, field, amplitude and phase. We show that tomographic measurements are affected by additional noise in comparison with the direct detection of each observable by itself. The case of of coherent states has been analyzed in details and earlier estimations of tomographic precision are critically discussed.
Characterising quantum states of light in the 2 $μm$ band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 $μm$ pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3 dB bandwidth of 13.2 MHz, total conversion efficiency of 58% at 2.07 $μm$ and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the …
We discuss excess noise contributions of a practical balanced homodyne detector in Gaussian-modulated coherent-state (GMCS) quantum key distribution (QKD). We point out the key generated from the original realistic model of GMCS QKD may not be secure. In our refined realistic model, we take into account excess noise due to the finite bandwidth of the homodyne detector and the fluctuation of the local oscillator. A high speed balanced homodyne detector suitable for GMCS QKD in the telecommunication wavelength region is built and experimentally tested. The 3dB bandwidth of the balanced homodyne …
We address the problem of energy-error tradeoff in the discrimination between two linear passive quantum optical devices with a single use. We provide an analytical derivation of the optimal strategy for beamsplitters and an iterative algorithm converging to the optimum in the general case. We then compare the optimal strategy with a simpler strategy using coherent input states and homodyne detection. It turns out that the former requires much less energy in order to achieve the same performances.
Discrete-modulated continuous-variable quantum key distribution with homodyne detection is widely recognized for its ease of implementation, efficiency with respect to error correction, and its compatibility with modern optical communication devices. However, recent studies report that the application of homodyne detection obtains poor tolerance to excess noise and insufficient transmission distance, hence seriously restricting the large-scale deployment of quantum secure communication networks. In this paper, we propose a homodyne detection protocol using the quadrature phase shift keying tec…
Conditional homodyne detection of quadrature squeezing is compared with standard nonconditional detection. Whereas the latter identifies nonclassicality in a quantitative way, as a reduction of the noise power below the shot noise level, conditional detection makes a qualitative distinction between vacuum state squeezing and squeezed classical noise. Implications of this comparison for the realistic interpretation of vacuum fluctuations (stochastic electrodynamics) are discussed.
We propose an improved two-way continuous-variable quantum key distribution (CV QKD) protocol by adding proper random noise on the receiver's homodyne detection, the security of which is analysed against general collective attacks. The simulation result under the collective entangling cloner attack indicates that despite the correlation between two-way channels decreasing the secret key rate relative to the uncorrelated channels slightly, the performance of the two-way protocol is still far beyond that of the one-way protocols. Importantly, the added noise in detection is beneficial for the se…
We give a systematic theoretical description of homodyne detection in the case where both the signal and the local oscillator pass through the turbulent atmosphere. Imperfect knowledge of the local-oscillator amplitude is effectively included in a noisy density operator, leading to postprocessing noise. Alternatively, we propose a technique with monitored transmission coefficient of the atmosphere, which is free of postprocessing noise.
Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classi…
A quantum receiver is an essential element of quantum illumination (QI) which outperforms its classical counterpart, called classical-illumination (CI). However, there are only few proposals for realizable quantum receiver, which exploits nonlinear effects leading to increasing the complexity of receiver setups. To compensate this, in this article, we design a quantum receiver with linear optical elements for Gaussian QI. Rather than exploiting nonlinear effect, our receiver consists of a 50:50 beam splitter and homodyne detection. Using double homodyne detection after the 50:50 beam splitter,…
Understanding the fundamental sensitivity limit of an optical sensor requires a full quantum mechanical description of the sensing task. In this work, we calculate the fundamental (quantum) limit for discriminating between pure laser light and thermal noise in a photon-starved regime. The Helstrom bound for discrimination error probability for single mode measurement is computed along with error probability bounds for direct detection, coherent homodyne detection and the Kennedy receiver. A generalized Kennedy (GK) receiver is shown to closely approach the Helstrom limit. We present an experim…
In this paper, we propose an experimentally viable scheme to enhance the sensitivity of force detection in a hybrid optomechanical setup assisted by squeezed vacuum injection, beyond the standard quantum limit (SQL). The scheme is based on a combination of the coherent quantum noise cancellation (CQNC) strategy with a variational homodyne detection of the cavity output spectrum in which the phase of the local oscillator is optimized. In CQNC, realizing a negative-mass oscillator in the system leads to exact cancellation of the backaction noise from the mechanics due to destructive quantum inte…
Entangled systems with large quantum Fisher information (QFI) can be used to outperform the standard quantum limit of the separable systems in quantum metrology. However, the interaction between the system and the environments inevitably leads to decoherence and decrease of the QFI, and it is not clear whether the entanglement systems can be better resource than separable systems in the realistic physical condition. In this work, we study the steady QFI of two driven and collectively damped qubits with homodyne-mediated feedback. We show that the steady QFI can be significantly enhanced both i…
We address binary phase-shift-keyed communication channels based on Gaussian states and prove that squeezing improves state discrimination at fixed energy of the channel, also in the presence of phase diffusion. We then assess performances of homodyne detection against the ultimate quantum limits to discrimination, and show that homodyning achieves optimality in large noise regime. Finally, we consider noise in the preparation of the seed signal (before phase encoding) and show that also in this case squeezing may improve state discrimination in realistic conditions.
We present the characterization of a novel balanced homodyne detector operating in the mid-infrared. The challenging task of revealing non-classicality in mid-infrared light, e.~g. in quantum cascade lasers emission, requires a high-performance detection system. Through the intensity noise power spectral density analysis of the differential signal coming from the incident radiation, we show that our setup is shot-noise limited. We discuss the experimental results with a view to possible applications to quantum technologies, such as free-space quantum communication.
A pulsed balanced homodyne detector has been developed for precise measurements of electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (> 85 dB) and low electronic noise (730 electrons per pulse) provide a signal to noise ratio of 14 dB for the measurement of the quantum noise of individual pulses. Measurements at repetition rates up to 1 MHz are possible. As a test, quantum tomography of the coherent state is performed and the Wigner function and the density matrix are reconstructed with a 99.5% fidelity. The detection system can also be used f…
A new scheme is described for pulsed squeezed light generation using femtosecond pulses parametrically deamplified through a single pass in a thin (0.1mm) potassium niobate KNbO3 crystal, with a significant deamplification of about -3dB. The quantum noise of each individual pulse is registered in the time domain using a single-shot homodyne detection operated with femtosecond pulses and the best squeezed quadrature variance was measured to be 1.87 dB below the shot noise level. Such a scheme provides the basic ressource for time-resolved quantum communication protocols.
Asymmetry effects in homodyne and heterodyne measurements: Positive operator-valued measures and asymptotic security of Gaussian-continuous-variable quantum key distribution
ITMO University(伊托夫大学);Laboratory for Quantum Communications, ITMO University(伊托夫大学量子通信实验室);Laboratory of Quantum Processes and Measurements, ITMO University(伊托夫大学量子过程与测量实验室)
We design and demonstrate a resonant-type differential photodetector for low-noise quantum homodyne measurement at 500MHz optical sideband with 17MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5mW of continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measuremen…
Pulsed homodyne quantum tomography usually requires a high detection efficiency limiting its applicability in quantum optics. Here, it is shown that the presence of low detection efficiency ($<50\%$) does not prevent the tomographic reconstruction of quantum states of light, specifically, of Gaussian type. This result is obtained by applying the so-called "minimax" adaptive reconstruction of the Wigner function to pulsed homodyne detection. In particular, we prove, by both numerical and real experiments, that an effective discrimination of different Gaussian quantum states can be achieved. Our…
Optical homodyne detection has found use in a range of quantum technologies as both a characterisation tool and as a way to post-selectively generate non-linearities. So far optical implementations have been limited to bulk optics. Here we present the first homodyne detector fully integrated with silicon photonics and suitable for measurements of the quantum state of the electromagnetic field. This high speed, compact detector shows low noise operation, with 10 dB of clearance between shot noise and electronic noise, up to a speed of 160 MHz. These performances are suitable for on-chip charact…
We report an experimental demonstration of optimal measurements of small displacement and tilt of a Gaussian beam - two conjugate variables - involving a homodyne detection with a TEM10 local oscillator. We verify that the standard split detection is only 64% efficient. We also show a displacement measurement beyond the quantum noise limit, using a squeezed vacuum TEM10 mode within the input beam.
We address the experimental estimation of Gaussian quantum discord for two-mode squeezed thermal state, and demonstrate a measurement scheme based on a pair of homodyne detectors assisted by Bayesian analysis which provides nearly optimal estimation for small value of discord. Besides, though homodyne detection is not optimal for Gaussian discord, the noise ratio to the ultimate quantum limit, as dictacted by the quantum Cramer-Rao bound, is limited to about 10 dB.
The eight-port homodyne detection apparatus is analyzed in the framework of the operational theory of quantum measurement. For an arbitrary quantum noise leaking through the unused port of the beam splitter, the positive operator valued measure and the corresponding operational homodyne observables are derived. It is shown that such an eight-port homodyne device can be used to construct the operational quantum trigonometry of an optical field. The quantum trigonometry and the corresponding phase space Wigner functions are derived for a signal field probed by a classical local oscillator and a …
The practical homodyne detector model of continuous-variable quantum key distribution models the inherent imperfections of the practical homodyne detector, namely the limited detection efficiency and the electronic noise, into trusted loss. However, the conventional practical homodyne detector model is valid only when both the imperfections of the practical homodyne detector are calibrated. In this paper, we show a modified practical homodyne detector model that can model the imperfections separately. The phase-sensitive amplifier is further applied to compensate the imperfections of the pract…
Traditional method for measuring continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses resulted from many factors such as detector's quantum efficiency and mode mismatching between detected field and local oscillator. In this paper, we propose and analyze a new measurement method, which is realized by assisting the balanced homodyne detections with a high gain phase sensitive parametric amplifier. The employment of the high gain parametric amplifier helps to tackle the vacuum quantum noise originat…
We report on the successful implementation of a new approach to locking the frequencies of an OPO-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase-shifts induced by a cavity, which may be used for the purposes of frequency-locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement and has the distinct advantage that subsequent homodyne measurements are automatically phase-locked. The homodyne locking te…
The non-linearity of a conditional photon-counting measurement can be used to `de-Gaussify' a Gaussian state of light. Here we present and experimentally demonstrate a technique for photon number resolution using only homodyne detection. We then apply this technique to inform a conditional measurement; unambiguously reconstructing the statistics of the non-Gaussian one and two photon subtracted squeezed vacuum states. Although our photon number measurement relies on ensemble averages and cannot be used to prepare non-Gaussian states of light, its high efficiency, photon number resolving capabi…
We simulate the process of continuous homodyne detection of the radiative emission from a quantum system, and we investigate how a Bayesian analysis can be employed to determine unknown parameters that govern the system evolution. Measurement back-action quenches the system dynamics at all times and we show that the ensuing transient evolution is more sensitive to system parameters than the steady state of the system. The parameter sensitivity can be quantified by the Fisher information, and we investigate numerically and analytically how the temporal noise correlations in the measurement sign…
We describe a new scheme for the measurement of mean photon flux at an arbitrary optical sideband frequency using homodyne detection. Experimental implementation of the technique requires an AOM in addition to the homodyne detector, and does not require phase locking. The technique exhibits polarisation, frequency and spatial mode selectivity, as well as much improved speed, resolution and dynamic range when compared to linear photodetectors and avalanche photo diodes (APDs), with potential application to quantum state tomography and information encoding using an optical frequency basis. Exper…
We study the problem of determining the photon number statistics of an unknown quantum state by simultaneously measuring conjugate quadratures with double homodyne detectors. Classically, the sum of the squared outputs of the two homodyne detectors is proportional to the intensity (thus the photon number) of the input light. Quantum mechanically, due to vacuum noise, the above photon number measurement is intrinsically noisy. We quantify the information gain in a single-shot measurement and discuss potential applications of this technology in quantum key distribution. We also show that the pho…
We show that the full statistics of the two detectors outputs in a balanced homodyne detection setup involving a local oscillator in an ideal coherent state is experimentally accessible despite the excess noise existing in actual laser sources. This possibility is illustrated using phase randomized coherent states signals from which the statistics of Fock states can accurately be obtained. The experimental verification of the recently predicted [Kühn and Vogel, Phys. Rev. A, \textbf{98}, 013832 (2018)] two-detector correlation probability for Fock states is presented for states $\vert 1 \rangl…
Compared to the quantum noise in the measurement of the translational motion of a suspended mirror using laser light, the quantum noise in the measurement of the angular motion of a suspended mirror has not been investigated intensively despite its potential importance. In this article, an expression for the quantum noise in the angular motion measurement is explicitly derived. The expression indicates that one quadrature of the vacuum field of the first-order Hermite-Gaussian mode of light causes quantum sensing noise and the other causes quantum backaction noise, or in other words the first-…
There has been much recent interest in quantum metrology for applications to sub-Raleigh ranging and remote sensing such as in quantum radar. For quantum radar, atmospheric absorption and diffraction rapidly degrades any actively transmitted quantum states of light, such as N00N states, so that for this high-loss regime the optimal strategy is to transmit coherent states of light, which suffer no worse loss than the linear Beer's law for classical radar attenuation, and which provide sensitivity at the shot-noise limit in the returned power. We show that coherent radar radiation sources, coupl…
The eight-port homodyne detector is an optical circuit designed to perform the monitoring of two quadratures of an optical field, the signal. By using quantum Bose fields and quantum stochastic calculus, we give a complete quantum description of this apparatus, when used as quadrature detector in continuous time. We can treat either the travelling waves in the optical circuit, either the observables involved in the detection part: two couples of photodiodes, postprocessing of the output currents. The analysis includes imperfections, such as not perfectly balanced beam splitters, detector effic…
In a recent continuous-variable quantum memory experiment, one quadrature of light pulse is directly uploaded by the light-atom coupling whereas complementary quadrature is obtained by homodyne measurement of the out-coupled light. Subsequently, information from homodyne mea- surement is written into the memory by feed-back electro-optical control of the atomic state. Using the same experimental set-up, a deterministic noise excess free record of unknown quantum states to continuous-variable quantum atomic memory is proposed. Further, the memory experiment is extended by the pre-squeezing of t…
Cavity-assisted homodyne detection with a single photodiode
Institute for Applied Physics, Friedrich Schiller University Jena(耶拿弗里德里希·席勒大学应用物理研究所);Abbe Center of Photonics, Friedrich Schiller University Jena(耶拿弗里德里希·席勒大学阿贝光子学中心)
Boosting State Discrimination in Quantum Brownian Motion Channel via Memory-Induced Coherence Preservation
Federal University of Piauí(皮奥伊联邦大学);Federal University of Paraná(巴拉那联邦大学);Universidade Federal do ABC(ABC联邦大学);Southern University of Science and Technology(南方科技大学);University of Coimbra(科英布拉大学)
We propose a near-optimum receiver for the discrimination of binary phase-shift-keyed coherent states employing photon-number-resolving detectors. The receiver exploits a discrimination strategy based on both the so-called homodyne-like and the direct detection, thus resulting in a hybrid scheme. We analyse the performance and the robustness of the proposed scheme under realistic conditions, namely, in the presence of inefficient detection and dark counts. We show that the present hybrid setup is near-optimum and beats both the standard-quantum-limit and the performance of the Kennedy receiver…
We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can co…
We experimentally study a homodyne detection technique for the characterization of a quadrature squeezed field where the correlated bands, here created by four-wave mixing in a hot atomic vapor, are separated by a large frequency gap of more than 6 GHz. The technique uses a two-frequency local oscillator to detect the fluctuations of the correlated bands at a frequency accessible to the detection electronics. Working at low detection frequency, the method allows for the determination of both the amplitude and the phase of the squeezing spectrum. In particular, we show that the quadrature squee…
We report a large area photo-diode based homodyne detector for free-space quantum coherent communication. The detector's performance is studied in terms of detection bandwidth and electronic noise for shot-noise limited quantum signal detection. Using large area photo-diodes increases signal collection efficiency from turbulent atmospheric channels, in comparison with typical fibre based free-space homodyne detectors. Under identical atmospheric turbulence and receiver aperture conditions, our homodyne detector based on 1mm diameter photo-diode experiences 0dB loss due to turbulence while a 10…