Naoyuki Tamura, Naruhisa Takato, Atsushi Shimono, Yuki Moritani, Kiyoto Yabe, Yuki Ishizuka, Akitoshi Ueda, Yukiko Kamata, Hrand Aghazarian, Stephane Arnouts, Gabriel Barban, Robert H. Barkhouser, Renato C. Borges, David F. Braun, Michael A. Carr, Pierre-Yves Chabaud, Yin-Chang Chang, Hsin-Yo Chen, Masashi Chiba, Richard C. Y. Chou, You-Hua Chu, Judith G. Cohen, Rodrigo P. de Almeida, Antonio C. de Oliveira, Ligia S. de Oliveira, Richard G. Dekany, Kjetil Dohlen, Jesulino B. dos Santos, Leandro H. dos Santos, Richard S. Ellis, Maximilian Fabricius, Didier Ferrand, Decio Ferreira, Mirek Golebiowski, Jenny E. Greene, Johannes Gross, James E. Gunn, Randolph Hammond, Albert Harding, Murdock Hart, Timothy M. Heckman, Christopher M. Hirata, Paul Ho, Stephen C. Hope, Larry Hovland, Shu-Fu Hsu, Yen-Shan Hu, Ping-Jie Huang, Marc Jaquet, Yipeng Jing, Jennifer Karr, Masahiko Kimura, Matthew E. King, Eiichiro Komatsu, Vincent Le Brun, Olivier Le Fevre, Arnaud Le Fur, David Le Mignant, Hung-Hsu Ling, Craig P. Loomis, Robert H. Lupton, Fabrice Madec, Peter Mao, Lucas S. Marrara, Claudia Mendes de Oliveira, Yosuke Minowa, Chaz N. Morantz, Hitoshi Murayama, Graham J. Murray, Youichi Ohyama, Joseph Orndorff, Sandrine Pascal, Jefferson M. Pereira, Daniel J. Reiley, Martin Reinecke, Andreas Ritter, Mitsuko Roberts, Mark A. Schwochert, Michael D. Seiffert, Stephen A. Smee, Laerte Sodre, David N. Spergel, Aaron J. Steinkraus, Michael A. Strauss, Christian Surace, Yasushi Suto, Nao Suzuki, John Swinbank, Philip J. Tait, Masahiro Takada, Tomonori Tamura, Yoko Tanaka, Laurence Tresse, Orlando Verducci, Didier Vibert, Clement Vidal, Shiang-Yu Wang, Chih-Yi Wen, Chi-Hung Yan, Naoki Yasuda
备注:
17 pages, 10 figures. Proceeding of SPIE Astronomical Telescopes and Instrumentation 2016
PFS(Prime Focus Spectrograph)是8.2米斯巴鲁望远镜上的下一代设施仪器,是一种非常宽的视场,大规模多路复用,光学和近红外光谱仪。利用Subaru Prime Focus,2394根可重构光纤将分布在1.3度的视场内。光谱仪设计有三个臂的蓝色,红色和近红外相机,可以在一次曝光中同时观察380 nm到1260 nm的光谱,分辨率为~1.6- 2.7 A。在Kavli IPMU的倡议下,一项国际合作正在开发这一工具。该项目现已进入建设阶段,旨在于2017-2018年进行系统集成,随后于2018-2019年进行工程运营。本文概述了该工具、当前项目状况和未来发展方向。
英文摘要:
PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
Multi-fibers connectors systems for FOCCoS-PFS-Subaru
光纤电缆和连接器系统(FOCCoS)通过光纤电缆在2400个定位器和一组光谱仪之间提供光学连接,作为斯巴鲁望远镜PFS仪器的一部分。光纤电缆将沿路线分为3部分,电缆A、电缆B和电缆C,通过一组多光纤连接器连接。USCONEC公司生产研究中的多光纤连接器。USCONEC 32 F型号可以连接32根光纤,采用4 x 8矩阵排列。套圈由耐用的复合材料聚苯硫醚(PPS)基热塑性塑料制成。连接通过一个推/拉闩锁固定到位,连接器也可以通过从连接器前部突出的一对金属导销来区分。每个连接器将使用两根光纤监测连接程序。它被发现很容易抛光,而且它足够小,可以成组安装。像PFS这样的高度多路复用的仪器需要一个光纤连接器系统,可以提供出色的光学性能和可靠性。PFS需要两种不同类型的结构来组织连接器。塔连接器系统包括80个多光纤连接器,是一组连接器,用于连接电缆B(望远镜结构)和电缆C(定位器板)。Gang连接器系统是一组8个Gang连接器,每个连接器有12个多光纤连接器,用于连接电缆B(望远镜结构)和电缆A(光谱仪)。这些连接器系统和所选光纤的台架测试应测量光的吞吐量以及多次连接和断开后的稳定性。在本文中,我们描述了测试和程序来评估吞吐量和FRD增量。套圈的寿命也在评估中。
Focal Plane Alignment and Detector Characterization for the Subaru Prime Focus Spectrograph
我们描述的基础设施正在开发的斯巴鲁测量图像和红移(SuMIRe)的主要焦点光谱仪(PFS)的检测器对齐和表征。PFS将采用四台三通道光谱仪,工作波长范围为3800 $Å$至12600 $Å$。每个光谱仪将由两个可见光通道和一个近红外(NIR)通道组成,其中每个通道将使用单独的施密特相机将捕获的光谱成像到各自的探测器上。在可见光通道中,Hamamatsu 2k x 4k CCD将成对安装,以创建单个4k x 4k探测器,而NIR通道将使用单个Teledyne 4k x 4k H4RG HgCdTe设备。
Prime Focus Spectrograph on the Subaru Telescope: Overview of Science Operations
National Astronomical Observatory of Japan(日本国立天文台);Graduate Institute for Advanced Studies, SOKENDAI(综合研究大学院大学);Subaru Telescope, National Astronomical Observatory of Japan(昴星团望远镜,日本国立天文台)
Studying focal ratio degradation of optical fibers for Subaru Prime Focus Spectrograph
聚焦比退化(FRD)是由纤维光学引起的光角分布的变化。FRD对于光纤馈电的光谱天文系统很重要,因为它会导致信号丢失、光谱分辨率下降或光谱仪设计复杂性增加。Nacional de Astrofísica(LNA)开发了一种系统,可以准确和精确地测量FRD,使用绝对方法,也可以测量光纤吞吐量。本文介绍了计量系统,并显示了Polymicro纤维FBP129168190,FBP127165190和藤仓纤维128170190的测量。虽然这两种光纤的FRD很低,并且彼此相似,但了解这些光纤的确切特性非常重要,因为它们都将用于建造FOCCoS(光纤电缆和连接器系统),用于安装在斯巴鲁望远镜上的PFS(主焦点光谱仪)。
FIRST-PL: Commissioning the first visible photonic lantern spectrograph for sub-diffraction-limit astronomy on Subaru/SCExAO
University of Hawai‘i(夏威夷大学);University of Hawaii at Manoa(夏威夷大学马诺阿分校);Subaru Telescope, National Astronomical Observatory of Japan(昴星团望远镜,日本国立天文台);Observatoire de Paris, Université PSL(巴黎天文台,巴黎文理研究大学);Steward Observatory, University of Arizona(斯图尔德天文台,亚利桑那大学);Astrobiology Center(天体生物学中心);Univ. Grenoble Alpes, CNRS, IPAG(格勒诺布尔阿尔卑斯大学,法国国家科学研究中心,IPAG);University of California, Los Angeles(加州大学洛杉矶分校);Sydney Institute for Astronomy, School of Physics, The University of Sydney(悉尼天体物理研究所,悉尼大学物理学院);Optical Sharpeners(光学锐化器);California Institute of Technology(加州理工学院);Sydney Astrophotonic Instrumentation Laboratory, School of Physics, The University of Sydney(悉尼天体光子仪器实验室,悉尼大学物理学院);Astralis, School of Physics, University of Sydney(Astralis,悉尼大学物理学院);University of Texas, San Antonio(得克萨斯大学圣安东尼奥分校)
Fiber mode scrambler for the Subaru infrared Doppler instrument (IRD)
我们报告的结果,光纤模式扰频器的实验,红多普勒仪器(IRD)的斯巴鲁8.2米望远镜。IRD是一种光纤馈电的高精度径向速度(RV)仪器,用于在近红外波长下搜索附近M矮星周围的系外行星。这是一台带有中阶梯光栅的高分辨率光谱仪。预期的RV测量精度为1 m s-1,采用最先进的激光频率梳进行波长校准。在IRD观测中,多模光纤出口光强分布的变化是最重要的仪器噪声之一,它降低了RV测量精度。为了稳定光纤出口的光强分布,必须引入光纤扰模器。在以往的研究中,已经提出了几种模式扰频器,但有必要确定最合适的模式扰频器系统的IRD。因此,我们进行了各种模式扰频器,静态和动态的性能的系统测量。我们测试了不同长度的多模光纤、八角形光纤、双光纤扰码器和两种动态扰码器以及它们的组合。我们报告这些模式扰频器的性能,并提出候选模式扰频器系统的IRD。
Spectroscopy using a visible photonic lantern at the Subaru telescope: Laboratory characterization and first on-sky demonstration on Ikiiki (α Leo) and `Aua (α Ori)
Precision radial velocity measurements by the forward-modeling technique in the near-infrared
在近红外中精确的径向速度(RV)测量是探测和表征低质量恒星或具有较高磁活动的年轻恒星周围的系外行星的有力工具。然而,在近红外中随时间显著变化的强的大地吸收线和发射谱线的存在可以防止通过经典技术从这些光谱中提取RV信息,经典技术忽略或掩蔽大地线。我们提出了一种方法和流水线,以获得精确的RV从近红外光谱使用前向建模技术。我们将其应用于光谱与宽波长覆盖(Y,J,和H波段,同时),采取了斯巴鲁8.2米望远镜的红外多普勒(IRD)摄谱仪。我们的管道提取每个光谱段的光谱仪的瞬时仪器配置文件,基于与恒星光同时注入光谱仪的激光频率梳的参考光谱。这些配置文件是用来获得的内在恒星模板光谱,这是免费的仪器加宽和大地特征,以及模型和适合个人观察到的光谱在RV分析。实施了一系列的数值模拟,使用理论光谱,模仿IRD数据,我们测试的管道,并表明IRD可以实现$<2$ m s $^{-1}$精度缓慢旋转中晚期M矮星的信噪比$> 100$每像素在1000 nm。RV精度对各种恒星参数的依赖性(例如,$T_{\rm eff}$,$v\sin i$,[Fe/H])的混合,以及碲线混合对RV精度的影响。我们还将RV分析管道应用于GJ 699和TRAPPIST-1的观测光谱,表明摄谱仪和管道能够至少在几个月的时间尺度上具有$<3$ m s $^{-1}$的RV精度。
Combining spectroscopy and wavefront control at deep contrast with photonic lanterns
University of Texas-San Antonio(德克萨斯大学圣安东尼奥分校);Subaru Telescope, National Astronomical Observatory of Japan(昴星团望远镜,日本国立天文台);Astrobiology Center(天体生物学中心);Sydney Institute for Astronomy, School of Physics, University of Sydney(悉尼大学物理学院悉尼天体物理学研究所);The University of Sydney, Sydney Astrophotonic Instrumentation Laboratory(悉尼大学悉尼天体光子仪器实验室);California Institute of Technology(加州理工学院);Space Science and Engineering Initiative, College of Engineering, Institute for Astronomy, University of Hawai’i(夏威夷大学天体物理学院工程学院太空科学与工程倡议);University of California Los Angeles(加州大学洛杉矶分校)