arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1210.2728astro-ph.IM
收藏

Subaru望远镜主焦点摄谱仪(PFS)的摄谱仪仪器方案

A spectrograph instrument concept for the Prime Focus Spectrograph (PFS) on Subaru Telescope

Sébastien Vives, David Le Mignant, Fabrice Madec, Marc Jaquet, Eric Prieto, Laurent Martin, Olivier Le Fèvre, James Gunn, Michael Carr, Stephen Smee, Robert Bar… 展开作者

Sébastien Vives, David Le Mignant, Fabrice Madec, Marc Jaquet, Eric Prieto, Laurent Martin, Olivier Le Fèvre, James Gunn, Michael Carr, Stephen Smee, Robert Barkhouser, Hajime Sugai, Naoyuki Tamura

摘要:

我们描述了正在为SUBARU望远镜开发的SuMIRe主焦点光谱仪(PFS)的光谱仪光机概念的概念设计。SuMIRe PFS将由四个相同的光谱仪组成,每个光谱仪在主焦点处接收来自2400光纤机器人定位器的600根光纤。每个光谱仪将有三个通道,总共覆盖380 nm至1300 nm的波长范围。第1节总结了仪器的要求。我们在第2节中介绍了光学设计和光学性能和分析。第3节介绍了机械设计,其要求和建议的概念。最后,在第5节中描述了摄谱仪系统的AIT阶段。

英文摘要:

We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380 nm to 1300 nm. The requirements for the instrument are summarized in Section 1. We present the optical design and the optical performance and analysis in Section 2. Section 3 introduces the mechanical design, its requirements and the proposed concepts. Finally, the AIT phases for the Spectrograph System are described in Section 5.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑