arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1606.05566cond-mat.mes-hall
收藏

石墨烯气体渗透压计

Graphene Gas Osmometers

Robin J. Dolleman, Santiago J. Cartamil-Bueno, Herre S. J. van der Zant, Peter G. Steeneken

摘要:

在这里,它示出了在相同的压力下分离2种气体的石墨烯膜被渗透压偏转。渗透压是进入石墨烯封闭腔的气体渗透速率的差异的结果。通过干涉测量技术检测几层石墨烯膜的偏转,以测量它们的张力诱导的共振频率。使用谐振频率和压力之间的关系的校准测量,提取石墨烯上的时间依赖性渗透压。不同气体组合的渗透压显示出很大的差异,这可以通过基于不同气体渗透速率的模型来解释。因此,基于石墨烯膜的气体渗透压计具有~60 kHz/mbar的响应度和纳米尺度。

英文摘要:

Here it is shown that graphene membranes that separate 2 gases at identical pressure are deflected by osmotic pressure. The osmotic pressure is a consequence of differences in gas permeation rates into a graphene enclosed cavity. The deflection of the few layer graphene membranes is detected by an interferometric technique for measuring their tension-induced resonance frequency. Using a calibration measurement of the relation between resonance frequency and pressure, the time dependent osmotic pressure on the graphene is extracted. The osmotic pressure for different combinations of gases shows large differences that can be accounted for by a model based on the different gas permeation rates. Thus a graphene membrane based gas osmometer with a responsitivity of ~60 kHz/mbar and nanoscale dimensions is demonstrated.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑