arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1512.03349astro-ph.SR
收藏

首次对极贫金属星进行高精度差分丰度分析

The first high precision differential abundance analysis of Extremely Metal Poor stars

Henrique Reggiani, Jorge Meléndez, David Yong, Ivan Ramírez, Martin Asplund

摘要:

背景:对极端贫金属恒星的研究表明,化学丰度比[X/Fe]的均方根散射低至0.05 dex(12%)。目前还不清楚这是否反映了观测的不确定性或内在的天体物理散射所产生的物理条件在ISM的早期。目的:测量极端贫金属恒星的化学丰度比,以研究精确度的极限,并了解宇宙散射或观测误差是否占主导地位。研究方法:我们使用高分辨率(R $\sim 95,000$)和高信噪比(S/N $= 700$ at 5000 $Å$)HIRES/Keck光谱,通过逐线差分方法确定两颗极贫金属星之间的高精度差分丰度。我们确定了恒星G64-37相对于标准恒星G64-12的恒星参数。我们对这两颗恒星进行了EW测量,以获得在这两颗恒星中识别的谱线,并进行了光谱合成以研究碳丰度。结果如下:用微分法可以得到$σ$(T $_{eff}$)$=$ 27 K、$σ$(log $g$)$=$ 0.06 dex、$σ$([Fe/H])$=$ 0.02 dex和$σ$(v $_{t}$)$=$ 0.06 kms $^{-1}$的误差。我们估计的相对化学丰度的精度低至$σ$([X/Fe])$\approx$ 0.01 dex。小的不确定性表明,有真正的丰度差异大于测量误差。观察到的Li差异不能用质量的差异来解释,因为质量较小的恒星具有更多的Li。结论:对于极贫金属的恒星,有可能达到$\approx$ 0.01-0.05 dex左右的丰度精度,为研究银河系早期化学演化打开了新的窗口。

英文摘要:

Context: Studies of extremely metal-poor stars indicate that chemical abundance ratios [X/Fe] have an rms scatter as low as 0.05 dex (12 \%). It remains unclear whether this reflects observational uncertainties or intrinsic astrophysical scatter arising from physical conditions in the ISM at early times. Aims: Measure differential chemical abundance ratios in extremely metal-poor stars to investigate the limits of precision and to understand whether cosmic scatter or observational errors are dominant. Methods: We used high resolution (R $\sim 95,000$) and high S/N (S/N $= 700$ at 5000$Å$) HIRES/Keck spectra, to determine high precision differential abundances between two extremely metal-poor stars through a line-by-line differential approach. We determined stellar parameters for the star G64-37 with respect to the standard star G64-12. We performed EW measurements for the two stars for the lines recognized in both stars and performed spectral synthesis to study the carbon abundances. Results: The differential approach allowed us to obtain errors of $σ$(T$_{eff}$ ) $=$ 27 K, $σ$(log $g$) $=$ 0.06 dex, $σ$([Fe/H]) $=$ 0.02 dex and $σ$(v$_{t}$ ) $=$ 0.06 kms$^{-1}$. We estimated relative chemical abundances with a precision as low as $σ$([X/Fe]) $\approx$ 0.01 dex. The small uncertainties demonstrate that there are genuine abundance differences larger than the measurement errors. The observed Li difference can not be explained by the difference in mass, because the less massive star has more Li. Conclusions: It is possible to achieve an abundance precision around $\approx$ 0.01-0.05 dex for extremely metal-poor stars, opening new windows on the study of the early chemical evolution of the Galaxy.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑