The Tile Calorimeter (TileCal) is the central hadronic calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). The LHC is scheduled to undergo a major upgrade, in 2022, for the High Luminosity LHC (HL-LHC). The ATLAS upgrade program for high luminosity is split into three phases: Phase-0 occurred during $2013-2014$ and prepared the LHC for Run 2; Phase-I, foreseen for 2019, will prepare the LHC for Run 3, whereafter the peak luminosity reaches $2-3 \times 10^{34}$ cm$^{2}s^{-1}$; finally, Phase-II, which is foreseen for 2024, will prepare the collider for the HL-LHC operation ($5-7 \times 10^{34}$ cm$^{2}s^{-1}$). The TileCal main activities for Phase-0 were the installation of the new low voltage power supplies and the activation of the TileCal third layer signal for assisting the muon trigger at $1.0<|η|<1.3$ (TileMuon Project). In Phase-II, a major upgrade in the TileCal readout electronics is planned. Except for the photomultipliers tubes (PMTs), most of the on- and off-detector electronics will be replaced, with the aim of digitizing all PMT pulses at the front-end level. This work describes the TileCal upgrade activities, focusing on the TileMuon Project and the new on-detector electronics.
The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. The TileCal calibration system comprises radioactive source, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scintillation light to digitization. This contribution presents a brief description of the different TileCal calibration systems as well as the latest results on the…
TileCal is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. This sampling calorimeter uses iron plates as absorber and plastic scintillating tiles as the active material. A multi-faceted calibration system allows to monitor and equalize the calorimeter response at each stage of the signal production, from scintillation light to digitization. This calibration system is based on signal generation from different sources: a Cs radioactive source, laser light, charge injection and minimum bias events produced in proton-proton collisions. A brief descript…
This article describes the Laser calibration system of the Atlas hadronic Tile Calorimeter that has been used during the run 1 of the LHC. First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for …
The upgrade of the DA$Φ$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE-2 thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstruction of $K_L\to 2π^0$ events with photons hitting the quadrupoles a calorimeter with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. To match these requirements, we are designing a tile calorimeter, QCALT, where each single tile is readout by mean of SiPM for a total gran…
The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of $|η| < 1.7$. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by abou…
The Tile PreProcessor (TilePPr) is the core element of the Tile Calorimeter (TileCal) off-detector electronics for High-luminosity Large Hadron Collider (HL-LHC). The TilePPr comprises FPGA-based boards to operate and read out the TileCal on-detector electronics. The Tile Computer on Module (TileCoM) mezzanine is embedded within TilePPr to carry out three main functionalities. These include remote configuration of on-detector electronics and TilePPr FPGAs, interface the TilePPr with the ATLAS Trigger and Data Acquisition (TDAQ) system, and interfacing the TilePPr with the ATLAS Detector Contro…
The upgrade of the DA$Φ$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE$^2$ thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstruction of $K_L\to 2π^0$ events with photons hitting the quadrupoles, a tile calorimeter, QCALT, with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. We propose a tile calorimeter with a high granularity readout corresponding to about 2500 silicon photomultipliers (SiPM) o…
The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material (SiPM-on-tile). The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. 38 layers of the sampling structure are equipped with cassettes containing 5…
The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration system…
The Tile Calorimeter (TileCal) is one detector of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal is a sampling calorimeter made of steel plates and plastic scintillators which are readout using approximately 10,000 PhotoMultipliers Tubes (PMTs). In 2024, the LHC will undergo a series of upgrades towards a High Luminosity LHC (HL-LHC) to deliver up to 7.5 times the current nominal instantaneous luminosity. The ATLAS Tile Phase II Upgrade will accommodate detector and Data AcQuisition (DAQ) system to the HL-LHC requirements. The detector electronics will be redesigned using a n…
The Tile Calorimeter (TileCal) is a sampling hadronic calorimeter covering the central region of the ATLAS experiment. TileCal uses steel as absorber and plastic scintillators as active medium. The scintillators are read-out by the wavelength shifting fibres coupled to the photomultiplier tubes (PMTs). The analogue signals from the PMTs are amplified, shaped, digitized by sampling the signal every 25 ns and stored on detector until a trigger decision is received. The TileCal front-end electronics reads out the signals produced by about 10000 channels measuring energies ranging from about 30 Me…
The High Luminosity Large Hadron Collider (HL-LHC) will have a peak luminosity of $5\times10^{34} $cm$^{-2} $\,s$^{-1}$, five times higher than the design luminosity of the LHC. The hadronic ATLAS Tile Calorimeter TileCal) is a sampling calorimeter with steel as absorber and plastic scintillators as active medium. The light produced in the scintillating tiles is guided to photomultiplier tubes (PMTs), where analogue signals are produced to be shaped and conditioned before being digitized every 25\,ns. TileCal Phase-II Upgrade for the HL-LHC will allow the system can cope with the increased rad…
TileCal, the central hadronic calorimeter of the ATLAS detector is composed of plastic scintillators interleaved by steel plates, and wavelength shifting optical fibres. The optical properties of these components are known to suffer from natural ageing and degrade due to exposure to radiation. The calorimeter was designed for 10 years of LHC operating at the design luminosity of $10^{34}$cm$^{-2}$s$^{-1}$. Irradiation tests of scintillators and fibres have shown that their light yield decrease by about 10% for the maximum dose expected after 10 years of LHC operation. The robustness of the Til…
The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS detector at the LHC. It is a sampling calorimeter consisting of alternating thin steel plates and scintillating tiles. Wavelength shifting fibers coupled to the tiles collect the produced light and are read out by photomultiplier tubes. Currently, an analog sum of the processed signal of several photomultipliers serves as input to the first level of trigger. Photomultiplier signals are then digitized and stored on detector and are only transferred off detector once the first trigger acceptance h…
The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by measuring details of the shower development and combining them with the data of the tracking system (particle flow). The prototype utilises scintillating tiles that are read out by novel Silicon Photomultipliers (SiPMs) and takes into account all design aspects that are demanded by the intended operation at the ILC. Currently, a new 12 layer prototype with about 340…
The present article introduces a novel ASIC architecture, designed in the context of the ATLAS Tile Calorimeter upgrade program for the High-Luminosity phase of the Large Hadron Collider at CERN. The architecture is based on radiation-tolerant 130 nm Complementary Metal-Oxide-Semiconductor technology, embedding both analog and digital processing of detector signals. A detailed description of the ASIC is given in terms of motivation, design characteristics and simulated and measured performance. Experimental studies, based on 24 prototype units under real particle beam conditions are also prese…
We present light yield and uniformity measurements of square and hexagonal tiles read out with silicon photomultipliers via a Y11 wavelength-shifting fiber or directly from the side or from the center at the top face. All tiles are 3~mm thick and have an area of $\rm 9~cm^2$. The sides are wrapped with two layers of Teflon tape while top and bottom faces are covered with two layers of Tyvec paper. We further show the first light yield and uniformity measurements of ATLAS Tile Calorimeter (TileCal) tiles with MPPC readout. This study has been motivated by looking into a possible phase 3 upgrade…
The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the most central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The ATLAS upgrade program is divided in three phases: The Phase~0 occurs during 2013-2014, Phase~1 during 2018-1019 and finally Phase~2, which is foreseen for 2022-2023, whereafter the peak luminosity will reach 5-7 x 10$^{34}$ cm$^2$s$^{-1}$ (HL-LHC). The main TileCal upgrade is focused on the Phase~2 period. The upgrade aims at replacing the majority of the on- and off-detector electronics so that all calorimeter sig…
The ATLAS hadronic Tile Calorimeter will undergo major upgrades to the on- and off-detector electronics in preparation for the High Luminosity program of the Large Hadron Collider (HL-LHC) in 2026, so that the system can cope with the HL-LHC increased radiation levels and out-of-time pileup. The on-detector electronics of the upgraded system will continuously digitize and transmit all photo-multiplier signals to the off-detector systems at a 40 MHz rate. The off-detector electronics will store the data in pipeline buffers, produce digital hadronic tower sums for the ATLAS Level-0 trigger syste…
Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb$^{-1}$. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as …
TileCal is the central hadronic calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). It is a sampling detector where scintillating tiles are embedded in steel absorber plates. The tiles are grouped forming cells, which are read-out on both sides by photomultiplier tubes (PMTs). The PMT digital samples are transmitted to the Read-Out Drivers (ROD) located in the back-end system for the events accepted by the Level 1 trigger system. The ROD is the core element of the back-end electronics and it represents the interface between the front-end electronics and the ATLAS overall Da…
The front face of the CDF central calorimeter is being equipped with a new Preshower detector, based on scintillator tiles read out by WLS fibers, in order to cope with the luminosity increase provided by the Main Injector during the Tevatron's Run II data taking. A light yield of about 40 pe/MIP at the tile exit was obtained, exceeding the design requirements.
The Phase-2 ATLAS upgrade for the High Luminosity Large Hadron Collider (HL-LHC) has motivated progressive redesigns of the ATLAS Tile Calorimeter (TileCal) read-out link and control board (Daughterboard). The Daughterboard (DB) communicates with the off-detector electronics via two 4.6 Gbps downlinks and two pairs of 9.6 Gbps uplinks. Configuration commands and LHC timing is received through the downlinks by two CERN radiation hard GBTx ASICs and propagated through Ultrascale+ FPGAs to the front-end. Simultaneously, the FPGAs send continuous high-speed readout of digitized PMT samples, slow c…
A radiation-hard quad-channel 12-bit 40 MSPS pipeline analog-to-digital converter (ADC) has been designed for the trigger readout electronics Phase-I upgrade of the ATLAS Liquid Argon calorimeter, at the CERN Large Hadron Collider. The final version of the custom design, fabricated in a commercial 130 nm CMOS process, is presented and found to meet the system requirements for analog performance and radiation tolerance. The procedure for quality control of 17200 ADCs is described and the results are presented.
The CALICE analog HCAL is a highly granular calorimeter, proposed for the International Linear Collider. It is based on scintillator tiles, read out by silicon photomultipliers (SiPMs). The effects of gaps between the calorimeter tiles, as well as the non-uniform response of the tiles, in view of the impact on the energy resolution, are studied in Monte Carlo events. It is shown that these type of effects do not have a significant influence on the measurement of hadron showers.
The CALICE collaboration is currently developing an engineering prototype of an analog hadron calorimeter for a future linear collider detector. It is based on scintillating tiles that are individually read out by silicon photomultipliers. The prototype will contain about 2500 detector channels, which corresponds to one calorimeter layer and aims at demonstrating the feasibility of building a detector with fully integrated front-end electronics. The concept and engineering status of the prototype, as well as results from the DESY test setups are reported here.
This article documents the characteristics of the high voltage (HV) system of the hadronic calorimeter TileCal of the ATLAS experiment. Such a system is suitable to supply reliable power distribution into particles physics detectors using a large number of PhotoMultiplier Tubes (PMTs). Measurements performed during the 2015 and 2016 data taking periods of the ATLAS detector show that its performance, in terms of stability and noise, fits the specifications. In particular, almost all the PMTs show a voltage instability smaller than 0.5 V corresponding to a gain stability better than 0.5%. A sma…
The PreProcessor of the ATLAS Level-1 Calorimeter Trigger prepares the analogue trigger signals sent from the ATLAS calorimeters by digitising, synchronising, and calibrating them to reconstruct transverse energy deposits, which are then used in further processing to identify event features. During the first long shutdown of the LHC from 2013 to 2014, the central components of the PreProcessor, the Multichip Modules, were replaced by upgraded versions that feature modern ADC and FPGA technology to ensure optimal performance in the high pile-up environment of LHC Run 2. This paper describes the…
The ATLAS detector is set to undergo a substantial upgrade termed the "Phase-II" upgrade during the Long-Shutdown in preparation for the start of operation of the High Luminosity Large Hadron Collider (HL-LHC). This paper describes the development and implementation of the Phase-II upgrade low voltage power supply transformer-coupled buck converter (Brick) test bench. A large scale production of approximately 2048 finger low voltage power supplies, with an identical output voltage, is set to be undertaken in the year 2022. This production will culminate in the complete replacement of the LVPS …
The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment at LHC. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibers to photo-multiplier tubes (PMTs), located in the outer part of the calorimeter. The readout is segmented into about 5000 cells, each one being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of the full readout chain during the data taking, …
An optical link system is being developed for the ATLAS Liquid Argon Calorimeter Phase-II upgrade. The optical link system is responsible for transmit the data of over 182 thousand detector channels from 1524 Front-End Boards (FEBs) through 26 optical fibers per FEB over 150 meters to the counting room and brings clocks, bunch crossing reset signals and slow control/monitoring signals back to the FEBs. The optical link system is based on the Low-Power GigaBit Transceivers (lpGBTs) and the Versatile optical Transceiver (VTRx+) modules, which both are being developed for the High-Luminosity LHC …
Imaging hadronic calorimeters with scintillator readout use small scintillator tiles individually read out by silicon photomultipliers to achieve the necessary granularity needed for sophisticated reconstruction algorithms at future collider detectors. For a second generation prototype of the CALICE analog HCAL new, 3 mm thick scintillator tiles with an embedded wavelength shifting fiber and new photon sensor from CPTA are being fabricated. The availability of blue-sensitive SiPMs also allows fiberless coupling of the photon sensor to the tile, a technique requiring modified geometries to achi…
The Analogue Hadron Calorimeter (AHCAL) is being developed within the CALICE collaboration for experiments at a future lepton collider. It is a sampling calorimeter with alternating layers of steel absorber plates and plastic scintillator tiles as active material. In the SiPM on tile design, the tiles are directly coupled to silicon photomultipliers (SiPMs). The front-end electronics are integrated into the active layers of the calorimeter. They are designed for low power consumption by rapidly power cycling according to the beam structure of a linear accelerator. In 2017 and 2018, a new large…
The SiPM-on-tile technology, consisting of plastic scintillator tiles with typical sizes of a few cm$^2$ mounted on top of SiPMs, has been developed within the CALICE collaboration to enable automatized mass production of active elements for scintillator-based highly granular calorimeters. We present a study of the impact of misalignment of the scintillator tile with respect to the photon sensor on the response uniformity and on the absolute light yield for square, hexagonal and rhomboidal scintillator tiles of different sizes. A misalignment results in the formation of a dipole asymmetry of t…
The expected increase of total integrated luminosity by a factor of ten at the HL-LHC compared to the design goals for LHC essentially eliminates the safety factor for radiation hardness realized at the current cold amplifiers of the ATLAS Hadronic Endcap Calorimeter (HEC). New more radiation hard technologies have been studied: SiGe bipolar, Si CMOS FET and GaAs FET transistors have been irradiated with neutrons up to an integrated fluence of 2.2 \cdot 10^{16} n/cm2 and with 200 MeV protons up to an integrated fluence of 2.6 \cdot 10^{14} p/cm2. Comparisons of transistor parameters such as th…
During 2003 test beam session for ATLAS Tile Calorimeter a monitoring program has been developed to ease the setup of correct running condition and the assessment of data quality. The program has been built using the Online Software services provided by the ATLAS Online Software group. The first part of this note contains a brief overview of these services followed by the full description of Tile Calorimeter monitoring program architecture and features. Performances and future upgrades are discussed in the final part of this note.
This article describes the design, construction and use of a calibration and monitoring system, based on movable 137Cs gamma-ray sources, for the ATLAS Tile Calorimeter (TileCal). The sources, propelled by a water-based liquid through tubes that traverse all the calorimeter's cells, produce signals that precisely characterise the response of each tile, thereby providing very granular and accurate data on the response of TileCal to particles. The system has been used to guide and control the quality of the optical instrumentation of all TileCal modules, to set and equalise the dynamic range of …
CMS-HF Calorimeters have been undergoing a major upgrade for the last couple of years to alleviate the problems encountered during Run I, especially in the PMT and the readout systems. In this poster, the problems caused by the old PMTs installed in the detectors and their solutions will be explained. Initially, regular PMTs with thicker windows, causing large Cherenkov radiation, were used. Instead of the light coming through the fibers from the detector, stray muons passing through the PMT itself produce Cherenkov radiation in the PMT window, resulting in erroneously large signals. Usually, …
The design of a radiation-hard dual channel 12-bit 40 MS/s pipeline ADC with extended dynamic range is presented, for use in the readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider. The design consists of two pipeline A/D channels with four Multiplying Digital-to-Analog Converters with nominal 12-bit resolution each. The design, fabricated in the IBM 130 nm CMOS process, shows a performance of 68 dB SNDR at 18 MHz for a single channel at 40 MS/s while consuming 55 mW/channel from a 2.5 V supply, and exhibits no performance degradation after irr…
The CALICE collaboration is currently developing an engineering prototype of an analog hadron calorimeter for a future linear collider like the ILC. One main task of this prototype is to demonstrate the feasibility of building a realistic detector with fully integrated front-end electronics. To reach the required high jet energy resolution the detector is based on highly segmented read out layers. The signals are sampled by scintillating tiles that are individually read out by silicon photomultipliers. The readout chips are integrated into the calorimeter layers and are optimized for minimal p…
Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm (PFA). The AHCAL of CEPC uses steel as absorber and scintillator tiles read out by Silicon Photo-Multipliers (SiPMs) as sensitive medium. The energy linearity and resolution of the calorimeter depends on the light yield uniformity of sensitive medium. It is essential to qualify the entire detector production in order to select scintillator tiles with light yield…
The expected increase of total integrated luminosity by a factor ten at the HL-LHC compared to the design goals for LHC essentially eliminates the safety factor for radiation hardness realized at the current cold amplifiers of the ATLAS Hadronic End-cap Calorimeter (HEC). New more radiation hard technologies have been studied: SiGe bipolar, Si CMOS FET and GaAs FET transistors have been irradiated with neutrons up to an integrated fluence of 2.2 x 10^{16} n/cm^2 and with 200 MeV protons up to an integrated fluence of 2.6 x 10^{14} p/cm^2. Comparisons of transistor parameters such as the gain f…
The ATLAS experiment is designed to study the proton-proton collisions produced at the Large Hadron Collider (LHC) at CERN. Liquid argon sampling calorimeters are used for all electromagnetic calorimetry as well as hadronic calorimetry in the endcaps. After installation in 2004--2006, the calorimeters were extensively commissioned over the three--year period prior to first collisions in 2009, using cosmic rays and single LHC beams. Since then, approximately 27 fb$\mathbf{^{-1}}$ of data have been collected at an unprecedented center of mass energy. During all these stages, the calorimeter and …
Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough ro…
We propose extending parallel fiber dual readout calorimetry to tiles, more applicable to many future experimental requirements, with superior energy resolution. Monte Carlo (MC) studies indicate that a tile dual calorimeter including an integral Cerenkov-compensated e-m front end and further longitudinal segmentation, not possible with parallel fibers, has equivalent or better resolution. Besides comparison and tuning with dual tile calorimeter data, a MC can be extended to study other dual and then multiple tile sensors including tiles with higher contrast to em-hadron shower fluctuations wi…
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scale. We present the design of the HCAL and report on measured properties of more than 10 thousand SiPMs. We discuss the SiPM efficiency, gain, cross-talk, and noise rate dependence on bias voltage and temperature, including the spread in these parameters. We analyze the reasons for SiPM rejection and present the results of the long term stability stu…
The LHC will undergo a major upgrade starting in 2025 towards the High Luminosity LHC (HL-LHC) to increase the instantaneous luminosity by a factor of 5 to 7 compared to the nominal value. The Phase-II Upgrade (2025-2027) will require the trigger and readout electronics of the ATLAS experiment to operate with the stringent conditions imposed by the HL-LHC. During this upgrade, both on- and off-detector readout electronics of TileCal will be completely replaced with a new data acquisition which will provide full-granularity information to the ATLAS trigger system. The Compact Processing Modules…
The increased particle flux at the high luminosity phase of the Large Hadron Collider (HL-LHC), with instantaneous luminosities of up to 7.5 times the original design value, will have an impact on many sub-systems of the ATLAS detector. This contribution highlights the particular impacts on the ATLAS liquid argon calorimeter system, together with an overview of the various upgrade plans leading up to the HL-LHC. The higher luminosities are of particular importance for the forward calorimeters (FCal), where the expected increase in the ionization load poses a number of problems that can degrade…
Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future lepton collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now lies on improving their implementation in "technological prototypes", that are scalable to the full linear collider detector. The Analogue Hadronic Calorimeter (AHCAL) concept is a sampling calorimeter of tungsten or steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active components. The front-end electronics…
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges. The four to five-fold increase of the number of interactions per bunch crossing will require superior time resolution and noise rejection capabilities. For these reasons the electronics readout has been completely redesigned. A dual gain trans-impedance amplifier and an ASIC providing two 160 MHz ADC channels, gain selection, and data compression will be used…
Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requ…
In this talk I discuss the use of calorimeter timing both for detector commissioning and in searches for new physics. In particular I present real and simulated cosmic ray muons data results for the ATLAS Tile Calorimeter system. The analysis shows that several detector errors such as imperfect calibrations can be uncovered. I also demonstrate the use of ATLAS Tile Calorimeters excellent timing resolution in suppressing cosmic ray fake missing transverse energy in searches for supersymmetry.