干涉/色散混合光谱仪的高分辨光谱分析
Analysis of high-resolution spectra from a hybrid interferometric/dispersive spectrometer
摘要:
为了更充分地利用低成本、小占地面积的混合干涉/色散光谱仪,开发了一种数学重建技术,以从复杂的光谱图案中准确地捕获高分辨率和相对峰强度。法布里-珀罗标准具耦合到Czerny-Turner光谱仪,导致光谱分辨率增加超过一个数量级,而光谱仪尺寸没有相应增加。工业标准Hg 313.1555/313.1844 nm双重峰的测量产生0.682的比率,其与独立测量值和文献值完全一致。双重分离(29 pm)类似于424.437 nm处的U同位素位移(25 pm),这对监测核不扩散活动很有意义。此外,该技术被应用到LIBS测量的矿物朱砂(HgS),并导致在0.682的比率。这种重建方法可以使显着更小,便携式高分辨率仪器与同位素特异性,有利于各种光谱应用。
英文摘要:
To more fully take advantage of a low-cost, small footprint hybrid interferometric/dispersive spectrometer, a mathematical reconstruction technique was developed to accurately capture the high-resolution and relative peak intensities from complex spectral patterns. A Fabry-Perot etalon was coupled to a Czerny-Turner spectrometer, leading to increased spectral resolution by more than an order of magnitude without the commensurate increase in spectrometer size. Measurement of the industry standard Hg 313.1555/313.1844 nm doublet yielded a ratio of 0.682, which agreed well with an independent measurement and literature values. The doublet separation (29 pm) is similar to the U isotope shift (25 pm) at 424.437 nm that is of interest to monitoring nuclear nonproliferation activities. Additionally, the technique was applied to LIBS measurement of the mineral cinnabar (HgS) and resulted in a ratio of 0.682. This reconstruction method could enable significantly smaller, portable high-resolution instruments with isotopic specificity, benefiting a variety of spectroscopic applications.