超导纳米线单光子探测器的极限低系统暗计数率

Ultimate low system dark count rate for superconducting nanowire single-photon detector

Hiroyuki Shibata, Kaoru Shimizu, Hiroki Takesue, Yasuhiro Tokura

摘要:

暗计数率(DCR)是单光子探测器的一个关键参数。通过引入安装在光纤到光纤的光学工作台上的体光学带通滤波器,该光纤到光纤的光学工作台在3K下冷却并阻挡到5微米,我们将超导纳米线单光子探测器的DCR抑制了三个数量级以上。DCR受到通过20 nm带宽的信号通带的黑体辐射的限制。品质因数、系统检测效率和DCR分别为2.7 x 10^11、2.3%和0.001 Hz。将带宽缩窄至100 GHz时,DCR将被抑制至0.0001 Hz,品质因数将增加至1.8 x 10^12。

英文摘要:

The dark count rate (DCR) is a key parameter of single-photon detectors. By introducing a bulk optical band-pass filter mounted on a fiber-to-fiber optical bench cooled at 3 K and blocking down to 5 micrometer, we suppressed the DCR of a superconducting nanowire single-photon detector by more than three orders of magnitude. The DCR is limited by the blackbody radiation through a signal passband of 20 nm bandwidth. The figure of merit, system detection efficiency, and DCR were 2.7 x 10^11, 2.3 %, and 0.001 Hz, respectively. Narrowing the bandwidth to 100 GHz suppresses the DCR to 0.0001 Hz and the figure of merit increases to 1.8 x 10^12.