arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1506.04830eess.SYcs.ITcs.SYmath.IT
收藏

在功率和断电约束下,作为次级用户最大化智能电表与聚合器之间的链路吞吐量

Maximizing the Link Throughput between Smart-meters and Aggregators as Secondary Users under Power and Outage Constraints

Centre for Wireless Communications (CWC), University of Oulu(奥卢大学无线通信中心);University of Oulu(奥卢大学);São Paulo State University (UNESP)(圣保罗州立大学)

Pedro H. J. Nardelli, Mauricio de Castro Tomé, Hirley Alves, Carlos H. M. de Lima, Matti Latva-aho

AI总结:

本文研究在功率和断电约束下,作为次级用户最大化智能电表与聚合器之间的链路吞吐量,考虑了次级用户对主链路的干扰问题,通过泊松点过程建模移动用户空间分布,推导出最大吞吐量的闭式解。

摘要:

本文评估了智能电表到聚合器之间的通信链路作为(非授权)次级用户,其数据传输在(授权)主上行信道上进行。所提出的场景假设:(i)电表和聚合器的位置固定,因此使用高度定向天线;(ii)次级用户以有限功率传输,相对于主用户;(iii)电表的传输被协调以避免包碰撞;(iv)次级链路的鲁棒性由断电约束保证。在这些假设下,次级用户对主(基站)和其他次级用户造成的干扰可以忽略不计。然而,作为非授权用户,电表-聚合器链路会受到主网络移动用户干扰的影响,其位置和交通活动是未知的。为应对这种不确定性,我们把移动用户的空间分布建模为泊松点过程。然后,我们推导出在参考次级链路基础上,受发射功率和断电约束影响的最大可实现吞吐量的闭式解。我们的数值结果展示了这些约束对最优吞吐量的影响,证明在所研究的场景中,更频繁的断电事件会改善系统性能。我们还表明,相对较高的断电概率对从智能电表到聚合器传输的平均功率需求曲线的重建影响很小。

英文摘要:

This paper assesses the communication link from smart meters to aggregators as (unlicensed) secondary users that transmit their data over the (licensed) primary uplink channel. The proposed scenario assumes: (i) meters' and aggregators' positions are fixed so highly directional antennas are employed, (ii) secondary users transmit with limited power in relation to the primary, (iii) meters' transmissions are coordinated to avoid packet collisions, and (iv) the secondary links' robustness is guaranteed by an outage constraint. Under these assumptions, the interference caused by secondary users in both primary (base-stations) and other secondary users can be neglected. As unlicensed users, however, meter-aggregator links do experience interference from the mobile users of the primary network, whose positions and traffic activity are unknown. To cope with this uncertainty, we model the mobile users spatial distribution as a Poisson point process. We then derive a closed-form solution for the maximum achievable throughput with respect to a reference secondary link subject to transmit power and outage constraints. Our numerical results illustrate the effects of such constraints on the optimal throughput, evincing that more frequent outage events improve the system performance in the scenario under study. We also show that relatively high outage probabilities have little effect on the reconstruction of the average power demand curve that is transmitted from the smart-meter to the aggregator.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑