arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1505.05907physics.atom-phquant-ph
收藏

囚禁离子光钟微动的精确测定

Precise determination of micromotion for trapped-ion optical clocks

J. Keller, H. L. Partner, T. Burgermeister, T. E. Mehlstäubler

摘要:

由于捕获离子光谱中的相对系统频率不确定性接近低$10^{-18}$范围,运动频率偏移占不确定性预算的相当大的一部分。微动是一种驱动运动,基本上与保罗陷阱的原理有关,是这些系统中特别关注的问题。在这篇文章中,我们实验研究在这个水平上的三种常见的方法,最大限度地减少和确定微动幅度。我们开发了一个广义模型的光子相关技术的定量应用,这是适用于常见的制度,其中过渡线宽是可比的射频驱动频率。我们表明,由于低于$1\times 10^{-20}$的二阶多普勒频移的分数频率的不确定性可以实现。在交错测量与概念上更简单的解决边带方法的定量评价进行了验证。如果不进行深入内的兰姆-迪克制度,在$10^{-19}$的水平上的温度依赖的偏移观察到解决边带测量由于采样的内在微动。通过与光子相关测量的直接比较,我们表明,简单的实现参数加热方法是敏感的微动在$1\times 10^{-20}$的水平,以及。

英文摘要:

As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low $10^{-18}$ range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below $1\times 10^{-20}$ can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of $10^{-19}$ is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of $1\times 10^{-20}$ as well.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑