arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1505.03046cs.CV
收藏

利用卷积神经网络和随机视图聚合改进计算机辅助检测

Improving Computer-aided Detection using Convolutional Neural Networks and Random View Aggregation

National Institutes of Health Clinical Center(美国国立卫生研究院临床中心)

Holger R. Roth, Le Lu, Jiamin Liu, Jianhua Yao, Ari Seff, Kevin Cherry, Lauren Kim, Ronald M. Summers

摘要:

医学影像中的自动计算机辅助检测(CADe)已成为临床实践和研究的重要工具。最先进的方法通常显示出高灵敏度,但以每个患者的高假阳性率(FP)为代价。我们设计了一个两层的粗到细级联框架,首先运行的候选生成系统的灵敏度为$\sim$ 100%,但在高FP水平。通过利用现有的CAD系统,在此步骤中生成病变候选者的感兴趣区域或体积(ROI或VOI)的坐标,并作为第二层的输入,这是我们在本研究中的重点。在此第二阶段中,我们生成$N$ 2D(二维)或2.5D视图,通过采样通过缩放变换,随机平移和旋转相对于每个ROI的质心坐标。这些随机视图用于训练深度卷积神经网络(ConvNet)分类器。在测试中,训练的ConvNet被用来分配类(例如,病变、病理)概率,然后在每个ROI处对这些概率求平均以计算最终的每个候选分类概率。第二层表现为高度选择性的过程,以拒绝困难的假阳性,同时保持高灵敏度。在具有不同患者数量的三个不同数据集上评估所述方法:59名患者用于结肠癌转移检测,176名患者用于淋巴结检测,以及1,186名患者用于结肠息肉检测。实验结果表明,ConvNets能够很好地推广到不同的医学成像CADe应用程序,并优雅地扩展到各种数据集。我们提出的方法在所有情况下都显着提高了CADe性能。在每例患者3个FP时,CADe敏感性分别从57%提高到70%,从43%提高到77%,从58%提高到75%。

英文摘要:

Automated computer-aided detection (CADe) in medical imaging has been an important tool in clinical practice and research. State-of-the-art methods often show high sensitivities but at the cost of high false-positives (FP) per patient rates. We design a two-tiered coarse-to-fine cascade framework that first operates a candidate generation system at sensitivities of $\sim$100% but at high FP levels. By leveraging existing CAD systems, coordinates of regions or volumes of interest (ROI or VOI) for lesion candidates are generated in this step and function as input for a second tier, which is our focus in this study. In this second stage, we generate $N$ 2D (two-dimensional) or 2.5D views via sampling through scale transformations, random translations and rotations with respect to each ROI's centroid coordinates. These random views are used to train deep convolutional neural network (ConvNet) classifiers. In testing, the trained ConvNets are employed to assign class (e.g., lesion, pathology) probabilities for a new set of $N$ random views that are then averaged at each ROI to compute a final per-candidate classification probability. This second tier behaves as a highly selective process to reject difficult false positives while preserving high sensitivities. The methods are evaluated on three different data sets with different numbers of patients: 59 patients for sclerotic metastases detection, 176 patients for lymph node detection, and 1,186 patients for colonic polyp detection. Experimental results show the ability of ConvNets to generalize well to different medical imaging CADe applications and scale elegantly to various data sets. Our proposed methods improve CADe performance markedly in all cases. CADe sensitivities improved from 57% to 70%, from 43% to 77% and from 58% to 75% at 3 FPs per patient for sclerotic metastases, lymph nodes and colonic polyps, respectively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑