arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1410.2176eess.SYcs.SYmath.OCnlin.AO
收藏

通过插电式电动车提高电力电网暂态稳定性

Improving power grid transient stability by plug-in electric vehicles

Faculty of Electrical Engineering and Information Technologies, “Ss Cyril and Methodius” University(“圣西里尔和梅托迪乌斯”大学电气与信息工程学院);Potsdam Institute for Climate Impact Research(波茨坦气候影响研究所);Department of Physics, Humboldt University of Berlin(柏林洪堡大学物理系);Institute for Complex Systems and Mathematical Biology, University of Aberdeen(阿伯丁大学复杂系统与数学生物学研究所);Faculty of Computer Science and Engineering, “Ss Cyril and Methodius” University(“圣西里尔和梅托迪乌斯”大学计算机科学与工程学系);BioCircuits Institute, UC San Diego(加州大学圣地亚哥分校生物电路研究所)

Andrej Gajduk, Mirko Todorovski, Juergen Kurths, Ljupco Kocarev

AI总结:

本文提出利用插电式电动车作为分布式能源资源,在车辆到电网模式下提升电网暂态稳定性,通过调节电动车功率输出,显著降低电压波动并延长关键清除时间。

摘要:

插电式电动车(PEVs)可以在放电模式下作为分布式能源和电力资源运行,作为车辆到电网(V2G)设备,在充电模式下作为负载或电网到车辆(G2V)设备。已有文献表明,PEVs作为V2G系统可为可再生能源提供备用支持,提供无功功率支持、有功功率调节、负载平衡、峰荷削减、电流谐波滤波,提供辅助服务如频率控制和旋转备用,提高电网效率、稳定性和可靠性,降低公用事业运营成本并产生收益。本文表明,PEVs甚至可以提高电力电网的暂态稳定性,即在电网受到大扰动(如母线故障、发电机和支路跳闸、突然大负载变化)时的稳定性。提出了一种基于发电机涡轮机速度调节的电动车车队功率输出控制策略,并在新英格兰10单元39节点电力系统上进行了测试。通过调节电动车的功率输出,我们证明(1)大扰动导致的速度和电压波动可显著减少,最多减少5倍,(2)关键清除时间可延长20-40%。总体而言,PEVs控制策略使电网更加稳健。

英文摘要:

Plug-in electric vehicles (PEVs) can serve in discharge mode as distributed energy and power resources operating as vehicle-to-grid (V2G) devices and in charge mode as loads or grid-to-vehicle (G2V) devices. It has been documented that PEVs serving as V2G systems can offer possible backup for renewable power sources, can provide reactive power support, active power regulation, load balancing, peak load shaving,% and current harmonic filtering, can provide ancillary services as frequency control and spinning reserves, can improve grid efficiency, stability, reliability, and generation dispatch, can reduce utility operating costs and can generate revenue. Here we show that PEVs can even improve power grid transient stability, that is, stability when the power grid is subjected to large disturbances, including bus faults, generator and branch tripping, and sudden large load changes. A control strategy that regulates the power output of a fleet of PEVs based on the speed of generator turbines is proposed and tested on the New England 10-unit 39-bus power system. By regulating the power output of the PEVs we show that (1) speed and voltage fluctuations resulting from large disturbances can be significantly reduced up to 5 times, and (2) the critical clearing time can be extended by 20-40%. Overall, the PEVs control strategy makes the power grid more robust.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑