No Time for Dead Time: Timing analysis of bright black hole binaries with NuSTAR
Matteo Bachetti, Fiona A. Harrison, Rick Cook, John Tomsick, Christian Schmid, Brian W. Grefenstette, Didier Barret, Steven E. Boggs, Finn E. Christensen, Willi… 展开作者
Matteo Bachetti, Fiona A. Harrison, Rick Cook, John Tomsick, Christian Schmid, Brian W. Grefenstette, Didier Barret, Steven E. Boggs, Finn E. Christensen, William W. Craig, Andrew C. Fabian, Felix Fürst, Poshak Gandhi, Charles J. Hailey, Erin Kara, Thomas J. Maccarone, Jon M. Miller, Katja Pottschmidt, Daniel Stern, Phil Uttley, Dominic J. Walton, Jörn Wilms, William W. Zhang
Timing of high-count rate sources with the NuSTAR Small Explorer Mission requires specialized analysis techniques. NuSTAR was primarily designed for spectroscopic observations of sources with relatively low count-rates rather than for timing analysis of bright objects. The instrumental dead time per event is relatively long (~2.5 msec), and varies by a few percent event-to-event. The most obvious effect is a distortion of the white noise level in the power density spectrum (PDS) that cannot be modeled easily with the standard techniques due to the variable nature of the dead time. In this paper, we show that it is possible to exploit the presence of two completely independent focal planes and use the cross power density spectrum to obtain a good proxy of the white noise-subtracted PDS. Thereafter, one can use a Monte Carlo approach to estimate the remaining effects of dead time, namely a frequency-dependent modulation of the variance and a frequency-independent drop of the sensitivity to variability. In this way, most of the standard timing analysis can be performed, albeit with a sacrifice in signal to noise relative to what would be achieved using more standard techniques. We apply this technique to NuSTAR observations of the black hole binaries GX 339-4, Cyg X-1 and GRS 1915+105.
No Time for Dead Time: Use the Fourier Amplitude Differences to Normalize Dead-time-affected Periodograms
死时间通过在功率密度谱中产生强烈的失真来影响X射线天文学中使用的许多仪器。这可能使得难以对源的非周期性变化进行建模或寻找准周期振荡。虽然在某些仪器中,可以对死区时间影响的功率谱进行简单的先验校正,但对于其他仪器(如NuSTAR),情况并非如此,其中死区时间是非恒定的且较长(约2.5 ms)。Bachetti et al. 2015提出了从同一仪器内独立探测器的光变曲线获得的共谱作为一种可能的解决方案,但这种解决方案始终只是一种部分解决方案:测量的均方根仍然受到死区时间的影响,因为共谱的功率分布宽度以频率依赖的方式受到死区时间的调制。在这封信中,我们提出了一个新的,强大的方法来规范cospectures,甚至功率密度谱,有一些警告。我们的方法使用来自两个独立检测器的傅立叶幅度的差异来表征和过滤掉死区时间的影响。这种方法对于精确模拟从受NuSTAR和ASTROSAT等当前飞行任务以及IXPE等未来飞行任务上的空载时间影响的仪器得出的周期图至关重要
Timing and Spectral Analysis of the 2024 Outburst of 2S 1553$-$542 with NuSTAR and NICER
University of Groningen(格罗宁根大学);Wuhan University(武汉大学);Shanghai Astronomical Observatory, Chinese Academy of Sciences(中国科学院上海天文台);Guizhou Minzu University(贵州民族大学)
The first comprehensive spectral and timing study of the ultra-compact X-ray binary 4U 1812-12 with NICER and NuSTAR
Department of physics, Visva-Bharati(维斯瓦-巴拉蒂大学物理系);Indian Institute Of Astrophysics (IIA)(印度天体物理研究所);Inter-University Centre for Astronomy & Astrophysics (IUCAA)(天文与天体物理跨大学中心)
Timing and Spectral Studies of PSR J2022+3842 with NICER and NuSTAR
Yunnan University(云南大学);Nanjing Normal University(南京师范大学);China West Normal University(西华师范大学);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学)
State-Dependent X-ray Variability in Cygnus X-1: A 12-Year NuSTAR Timing Study of Accretion Flow Geometry
Boston University(波士顿大学);Raman Research Institute(拉曼研究所);Indian Institute of Science Education and Research Bhopal(印度科学教育与研究学院博帕尔分校);Florida International University(佛罗里达国际大学);Miami Dade College(迈阿密戴德学院);Osmania University(奥斯曼尼亚大学);Physical Research Laboratory(物理研究实验室);UN Center for Space Science and Technology Education in Asia and Pacific (CSSTEAP)(联合国亚洲及太平洋空间技术和外空活动教育训练中心);Sardar Vallabhbhai National Institute of Technology, Surat(萨达尔·瓦拉巴伊国立技术学院苏拉特分校);Pondicherry University(本地治里大学);School of Sciences, JAIN (Deemed-to-be University), Bengaluru(JAIN(视为大学)班加罗尔理学院);Janusz Gil Institute of Astronomy, University of Zielona Góra(绿山大学扬努什·吉尔天文学研究所)
Revisiting the 2021 Outburst of the BHC MAXI J1803-298 Using NICER, NuSTAR, and Insight-HXMT Data
South-Western Institute for Astronomy Research, Yunnan University(西南天体物理研究所,云南大学);Indian Center for Space Physics(印度空间物理中心);Institute of Astronomy, National Tsing Hua University(国立清华大学天文研究所)
The 2025 outburst of IGR J17511-3057: timing and spectral insights from NICER and NuSTAR
Technical University of Denmark(丹麦技术大学);NASA's Goddard Space Flight Center(美国宇航局戈达德太空飞行中心);INAF–Osservatorio Astronomico di Brera(意大利国家天体物理研究所布雷拉天文台);INAF Osservatorio Astronomico di Roma(意大利国家天体物理研究所罗马天文台);INAF/IASF Palermo(意大利国家天体物理研究所帕勒莫空间天体物理学研究所);Howard University(霍华德大学);University of Southampton(南安普顿大学);McGill University(麦吉尔大学);Trottier Space Institute at McGill University(麦吉尔大学特罗蒂尔太空研究所);Massachusetts Institute of Technology(麻省理工学院);Istanbul University(伊斯坦布尔大学)
Energy-resolved pulse profiles of Vela X-1: cross-calibrating XMM-Newton and NuSTAR to trace spectral features
INAF - IASF Palermo(意大利国家天体物理研究所帕勒莫天文物理研究所);Università degli Studi di Palermo(巴勒莫大学);European Space Agency (ESA)(欧洲航天局);University of Geneva(日内瓦大学);INAF, Osservatorio Astronomico di Brera(意大利国家天体物理研究所布里拉天文台);Friedrich-Alexander-Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡大学);Anton Pannekoek Institute for Astronomy, University of Amsterdam(阿姆斯特丹大学安东·潘内克克天文学研究所)
MAXI J1820+070 with NuSTAR I. An increase in variability frequency but a stable reflection spectrum: coronal properties and implications for the inner disc in black hole binaries
Broadband Timing and Spectral Study of Accreting Millisecond X-ray Pulsar SAX J1808.4$-$3658 during Its 2022 Outburst
Inter-University Centre for Astronomy and Astrophysics (IUCAA)(大学间天文学与天体物理学中心);Universitá degli Studi di Cagliari(卡利亚里大学);Department of Applied Sciences, UPES(印度石油大学应用科学系)
European Space Agency (ESA)(欧洲航天局);European Space Astronomy Center (ESAC)(欧洲航天天文中心);Instituto de Astrofísica de Canarias(加那利群岛天体物理学研究所);Universidad de La Laguna(拉帕鲁尼亚大学)
Broadband X-ray Spectral and Timing Analyses of the Black Hole Binary Candidate Swift J1658.2-4242: Rapid Flux Variation and the Turn-on of a Transient QPO