The GRAVITY metrology system: modeling a metrology in optical fibers
N. Blind, H. Huber, F. Eisenhauer, J. Weber, S. Gillessen, M. Lippa, L. Burtscher, O. Hans, M. Haug, F. Haussmann, S. Huber, A. Janssen, S. Kellner, Y. Kok, T. … 展开作者
N. Blind, H. Huber, F. Eisenhauer, J. Weber, S. Gillessen, M. Lippa, L. Burtscher, O. Hans, M. Haug, F. Haussmann, S. Huber, A. Janssen, S. Kellner, Y. Kok, T. Ott, O. Pfuhl, E. Sturm, E. Wieprecht, A. Amorim, W. Brandner, G. Perrin, K. Perraut, C. Straubmeier
备注:
20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.
Studying focal ratio degradation of optical fibers for Subaru Prime Focus Spectrograph
聚焦比退化(FRD)是由纤维光学引起的光角分布的变化。FRD对于光纤馈电的光谱天文系统很重要,因为它会导致信号丢失、光谱分辨率下降或光谱仪设计复杂性增加。Nacional de Astrofísica(LNA)开发了一种系统,可以准确和精确地测量FRD,使用绝对方法,也可以测量光纤吞吐量。本文介绍了计量系统,并显示了Polymicro纤维FBP129168190,FBP127165190和藤仓纤维128170190的测量。虽然这两种光纤的FRD很低,并且彼此相似,但了解这些光纤的确切特性非常重要,因为它们都将用于建造FOCCoS(光纤电缆和连接器系统),用于安装在斯巴鲁望远镜上的PFS(主焦点光谱仪)。
GRAVITY+: reducing non-common-path aberrations for sub-10 μas astrometric accuracy
Max-Planck-Institut für Extraterrestrische Physik (MPE)(马克斯·普朗克地外物理研究所);CNRS, Sorbonne Universités(法国国家科学研究中心,索邦大学);European Southern Observatory(欧洲南方天文台);Canadian Institute for Theoretical Astrophysics(加拿大理论天体物理研究所);LESIA, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Univ. Paris 06, Univ. Paris Diderot, Sorbonne Paris Cité(巴黎天文台天体物理学与空间研究所,巴黎文理研究大学,法国国家科学研究中心,索邦大学,巴黎第六大学,巴黎第七大学,巴黎公社);Faculdade de Engenharia, Universidade do Porto(波尔图大学工程学院);School of Physics & Astronomy, University of Southampton(南安普顿大学物理与天文学院);Max Planck Institute for Astronomy(马克斯·普朗克天文学研究所);Univ. Grenoble Alpes, CNRS, IPAG(格勒诺布尔阿尔卑斯大学,法国国家科学研究中心,天体物理学与行星学研究所);st Institute of Physics, University of Cologne(科隆大学第一物理研究所)
SIMTERFERE: An optical interferometry simulator for quantifying the coherent flux stability of VLTI/GRAVITY+. Reaching per mill stability: Application to exoplanet spectroscopy
Max-Planck-Institut für Astronomie(马克斯·普朗克天文学研究所);Fakultät für Physik und Astronomie, Universität Heidelberg(海德堡大学物理与天文学学院);Max-Planck-Institut für extraterrestrische Physik(马克斯·普朗克地外物理学研究所);I. Physikalisches Institut, Universität zu Köln(科隆大学第一物理研究所)