arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1407.1880astro-ph.IM
收藏

SPIDER球载望远镜的指向控制

Pointing control for the SPIDER balloon-borne telescope

Jamil A. Shariff, Peter A. R. Ade, Mandana Amiri, Steven J. Benton, Jamie J. Bock, J. Richard Bond, Sean A. Bryan, H. Cynthia Chiang, Carlo R. Contaldi, Brendan… 展开作者

Jamil A. Shariff, Peter A. R. Ade, Mandana Amiri, Steven J. Benton, Jamie J. Bock, J. Richard Bond, Sean A. Bryan, H. Cynthia Chiang, Carlo R. Contaldi, Brendan P. Crill, Olivier P. Doré, Marzieh Farhang, Jeffrey P. Filippini, Laura M. Fissel, Aurelien A. Fraisse, Anne E. Gambrel, Natalie N. Gandilo, Sunil R. Golwala, Jon E. Gudmundsson, Mark Halpern, Matthew Hasselfield, Gene C. Hilton, Warren A. Holmes, Viktor V. Hristov, Kent D. Irwin, William C. Jones, Zigmund D. Kermish, Chao-Lin Kuo, Carolyn J. MacTavish, Peter V. Mason, Krikor G. Megerian, Lorenzo Moncelsi, Tracy A. Morford, Johanna M. Nagy, C. Barth Netterfield, Roger O'Brient, Alexandra S. Rahlin, Carl D. Reintsema, John E. Ruhl, Marcus C. Runyan, Juan D. Soler, Amy Trangsrud, Carole E. Tucker, Rebecca S. Tucker, Anthony D. Turner, Alexis C. Weber, Donald V. Wiebe, Edward Y. Young

摘要:

本文介绍了SPIDER实验指向系统的技术和控制方法。SPIDER是一个球载偏振计,旨在探测宇宙微波背景辐射偏振中的原始引力波印记。我们描述了望远镜的方位驱动的两个主要组成部分:反作用轮和电动枢轴。13 kHz PI控制回路在数字信号处理器上运行,并具有来自光纤速率陀螺仪的反馈。该系统可实现方位角速度的控制,均方根误差< 0.02度/秒。为了控制高度,SPIDER使用步进电机驱动的线性致动器来旋转低温恒温器,其中包含光学仪器,相对于外部框架。以这种方式控制每个轴的速度,机载飞行计算机上的高级控制回路可以实现实验所需的指向和扫描观察模式。我们已经完成了一项重要的任务,即以0.8度/秒的峰值加速度$^2$和6度/秒的峰值速度在方位角上正弦扫描5000磅有效载荷。我们可以做到这一点,同时可靠地实现亚弧分指向控制精度。

英文摘要:

We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑