arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1406.6115physics.ins-dethep-ex
收藏

重光子搜索测试探测器

The Heavy Photon Search Test Detector

Marco Battaglieri, Sergey Boyarinov, Stephen Bueltmann, Volker Burkert, Andrea Celentano, Gabriel Charles, William Cooper, Chris Cuevas, Natalia Dashyan, Raffae… 展开作者

Marco Battaglieri, Sergey Boyarinov, Stephen Bueltmann, Volker Burkert, Andrea Celentano, Gabriel Charles, William Cooper, Chris Cuevas, Natalia Dashyan, Raffaella DeVita, Camille Desnault, Alexandre Deur, Hovanes Egiyan, Latifa Elouadrhiri, Rouven Essig, Vitaliy Fadeyev, Clive Field, Arne Freyberger, Yuri Gershtein, Nerses Gevorgyan, Francois-Xavier Girod, Norman Graf, Mathew Graham, Keith Griffioen, Alexander Grillo, Michel Guidal, Gunther Haller, Per Hansson Adrian, Ryan Herbst, Maurik Holtrop, John Jaros, Scott Kaneta, Mahbub Khandaker, Alexey Kubarovsky, Valery Kubarovsky, Takashi Maruyama, Jeremy McCormick, Ken Moffeit, Omar Moreno, Homer Neal, Timothy Nelson, Silvia Niccolai, Al Odian, Marco Oriunno, Rafayel Paremuzyan, Richard Partridge, Sarah Phillips, Emmanuel Rauly, Benjamin Raydo, Joseph Reichert, Emmanuel Rindel, Philippe Rosier, Carlos Salgado, Philip Schuster, Youri Sharabian, Daria Sokhan, Stepan Stepanyan, Natalia Toro, Sho Uemura, Maurizio Ungaro, Hakop Voskanyan, Dieter Walz, Larry Weinstein, Bogdan Wojtsekhowski

摘要:

重光子搜索(HPS)是一项在固定目标电产生中搜索隐藏扇区光子的实验,正准备于2014年秋季在托马斯杰斐逊国家加速器设施(JLab)安装。作为该项目的第一阶段,HPS测试运行装置于2012年建成并运行,以证明实验的技术可行性,并确认触发率和占用率符合预期。本文介绍了HPS试车装置和读出电子学及其性能。在这种情况下,重光子可以被识别为e $^+$ e $^-$不变质谱中的窄峰,在三叉戟背景之上,或者作为具有从产生目标移位的衰变顶点的窄不变质量峰,因此需要带电粒子跟踪和顶点来检测它。在HPS测试运行中,带电粒子是用偶极磁铁内的紧凑型前向硅微带跟踪器测量的。电磁簇射在位于磁体后面的PbW 0 $_{4}$晶体量热计中检测到,并用于触发实验和识别电子和正电子。两个探测器都靠近光束线放置,并从上到下分开。这种布置提供了对低质量重光子的灵敏度,允许未散射的束的清晰通过,并且避免了来自靶的退化电子的喷射。即时和位移的e $^+$ e $^-$对之间的区分需要将第一层硅传感器放置在目标下游仅10 cm处。预期的信号很小,而三叉戟背景很大,因此实验需要非常大的统计数据。因此,HPS测试运行利用高速读出和数据采集电子设备以及快速触发器,以利用JLab的CEBAF加速器的基本100%占空比。

英文摘要:

The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑