摘要:

高通量、低内工作角(IWA)相位掩模日冕仪对于直接成像和表征(通过光谱学)类地行星至关重要。然而,低IWA日冕仪的性能受到残余指向误差和其他低阶模式的限制。校正和校准日冕仪上游波前像差的程度驱动日冕仪性能。解决这一问题对于防止日冕泄漏至关重要,因此我们开发了一种基于Lyot的低阶波前传感器(LLOWFS)来控制日冕中的波前像差。LLOWFS使用下游光瞳平面中的反射Lyot光阑来监测被日冕掩模拒绝的星光。LLOWFS的早期实施在LESIA,巴黎天文台证明了一个开环测量精度为0.01 λ/D的638 nm的倾斜时,与四象限相位掩模(MAPM)在实验室中使用。为了进一步证明我们的概念,我们在斯巴鲁望远镜的斯巴鲁日冕仪极端AO(SCExAO)系统上安装了反射Lyot光阑,并修改了系统以支持小型IWA相位掩模日冕仪(< 1 λ/D)在天空中,例如,八分相位掩模,八分相位掩模,矢量涡旋日冕仪和相位诱导振幅切趾复相位掩模日冕仪,其目标是获得毫弧,二是精准度。实验室测量结果表明,矢量涡旋日冕仪在1.55 μ m处具有倾转、倾斜、聚焦、斜向和右向像散。我们最初的天空结果表明,在1.6微米的倾斜,倾斜和焦点像差与矢量涡日冕的闭环精度< 7 × 10-3 λ/D。

英文摘要:

High throughput, low inner working angle (IWA) phase masks coronagraphs are essential to directly image and characterize (via spectroscopy) earth-like planets. However, the performance of low-IWA coronagraphs is limited by residual pointing errors and other low-order modes. The extent to which wavefront aberrations upstream of the coronagraph are corrected and calibrated drives coronagraphic performance. Addressing this issue is essential for preventing coronagraphic leaks, thus we have developed a Lyot-based low order wave front sensor (LLOWFS) to control the wavefront aberrations in a coronagraph. The LLOWFS monitors the starlight rejected by the coronagraphic mask using a reflective Lyot stop in the downstream pupil plane. The early implementation of LLOWFS at LESIA, Observatoire de Paris demonstrated an open loop measurement accuracy of 0.01 lambda/D for tip-tilt at 638 nm when used in conjunction with a four quadrant phase mask (FQPM) in the laboratory. To further demonstrate our concept, we have installed the reflective Lyot stops on the Subaru Coronagraphic Extreme AO (SCExAO) system at the Subaru Telescope and modified the system to support small IWA phase mask coronagraphs (< 1 lambda/D) on-sky such as FQPM, eight octant phase mask, vector vortex coronagraph and the phase induced amplitude apodization complex phase mask coronagraph with a goal of obtaining milli arc-second pointing accuracy. Laboratory results have shown the measurement of tip, tilt, focus, oblique and right astigmatism at 1.55 um for the vector vortex coronagraph. Our initial on-sky result demonstrate the closed loop accuracy of < 7 x 10-3 lambda/D at 1.6 um for tip, tilt and focus aberrations with the vector vortex coronagraph.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑