arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1801.09760astro-ph.IMastro-ph.EP
收藏

具有主动波前控制的成形瞳孔日冕仪对低阶像差灵敏度的实验室和空中验证

Laboratory and On-Sky Validation of the Shaped Pupil Coronagraph's Sensitivity to Low-Order Aberrations With Active Wavefront Control

Thayne Currie, N. Jeremy Kasdin, Tyler Groff, Julien Lozi, Nemanja Jovanovic, Olivier Guyon, Timothy Brandt, Frantz Martinache, Jeffery Chilcote, Nour Skaf, Jon… 展开作者

Thayne Currie, N. Jeremy Kasdin, Tyler Groff, Julien Lozi, Nemanja Jovanovic, Olivier Guyon, Timothy Brandt, Frantz Martinache, Jeffery Chilcote, Nour Skaf, Jonas Kuhn, Prashant Patak, Tomoyuki Kudo

摘要:

我们提出了早期的实验室模拟和广泛的天空测试验证的形状瞳孔日冕(SPC)背后的斯巴鲁Coronagaphic极端自适应光学(SCExAO)系统的极端AO校正光束的性能。在使用SCExAO内部光源/波前误差模拟器的测试中,SPC的归一化强度分布比Lyot日冕仪的退化更慢,因为低阶像差从极高值(S.R. $\sim$ 0.93--0.99)与目前地面极端AO系统(S.R. $\sim$ 0.74--0.93),然后将值略微降低至S.R.。$\sim$ 0.57。用SPC和其他日冕仪为棕矮星/行星宿主恒星HD 1160和HR 8799拍摄的天空SCExAO数据为SPC对低阶像差的鲁棒性提供了进一步的证据。从80%到70%的H波段Strehl比率,Lyot日冕仪的性能与SPC的性能相比,在天空中的退化速度可能比我们内部源模拟中看到的还要快。Lyot的5- $σ$对比度也比SPC下降得更快(2倍)。我们使用的SPC仅被设计为技术演示器,其对比度地板,吞吐量和外部工作角度与SCExAO当前的AO性能不匹配,并且对于HR 8799行星的成像调整不佳。然而,我们使用宽带模式下的SPC使用SCExAO/CHARIS探测HR 8799 cde,其中行星e的S/N在使用涡旋日冕仪获得的S/N的30%以内。成形瞳孔日冕仪是一种很有前途的设计,被证明在存在低阶像差的情况下是稳健的,可能非常适合未来的地面和天基直接成像观测,特别是那些侧重于后续系外行星表征和图像平面明确区域内深对比度技术演示的观测。

英文摘要:

We present early laboratory simulations and extensive on-sky tests validating of the performance of a shaped pupil coronagraph (SPC) behind an extreme-AO corrected beam of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. In tests with the SCExAO internal source/wavefront error simulator, the normalized intensity profile for the SPC degrades more slowly than for the Lyot coronagraph as low-order aberrations reduce the Strehl ratio from extremely high values (S.R. $\sim$ 0.93--0.99) to those characteristic of current ground-based extreme AO systems (S.R. $\sim$ 0.74--0.93) and then slightly lower values down to S.R. $\sim$ 0.57. On-sky SCExAO data taken with the SPC and other coronagraphs for brown dwarf/planet-hosting stars HD 1160 and HR 8799 provide further evidence for the SPC's robustness to low-order aberrations. From H-band Strehl ratios of 80% to 70%, the Lyot coronagraph's performance vs. that of the SPC may degrade even faster on sky than is seen in our internal source simulations. The 5-$σ$ contrast also degrades faster (by a factor of two) for the Lyot than the SPC. The SPC we use was designed as a technology demonstrator only, with a contrast floor, throughput, and outer working angle poorly matched for SCExAO's current AO performance and poorly tuned for imaging the HR 8799 planets. Nevertheless, we detect HR 8799 cde with SCExAO/CHARIS using the SPC in broadband mode, where the S/N for planet e is within 30% of that obtained using the vortex coronagraph. The shaped-pupil coronagraph is a promising design demonstrated to be robust in the presence of low-order aberrations and may be well-suited for future ground and space-based direct imaging observations, especially those focused on follow-up exoplanet characterization and technology demonstration of deep contrast within well-defined regions of the image plane.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑