A spaceborne gravity gradiometer concept based on cold atom interferometers for measuring Earth's gravity field
Olivier Carraz, Christian Siemes, Luca Massotti, Roger Haagmans, Pierluigi Silvestrin
备注:
10 pages, 6 figures The final publication is available at Springer via http://dx.doi.org/10.1007/s12217-014-9385-x. appears in Microgravity Science and Technology October 2014
We propose a concept for future space gravity missions using cold atom interferometers for measuring the diagonal elements of the gravity gradient tensor and the spacecraft angular velocity. The aim is to achieve better performance than previous space gravity missions due to a very low white noise spectral behavior and a very high common mode rejection, with the ultimate goals of determining the fine structures of the gravity field with higher accuracy than GOCE and detecting time-variable signals in the gravity field better than GRACE.
Bragg gravity-gradiometer using the $^1$S$_0$-$^3$P$_1$ intercombination transition of $^{88}$Sr
提出了一种基于碱土金属原子($^{88}$ Sr)的物质波干涉的梯度计。原子外部自由度的相干操纵是通过大动量转移布拉格衍射获得的,由失谐远离窄的$^1$ S $_0$ - $^3$ P $_1$互组合跃迁的激光场驱动。我们使用一个良好控制的人工梯度,实现通过改变干涉仪序列期间的布拉格脉冲的相对频率,为了表征梯度仪的灵敏度。对于20 ms的干涉仪时间,灵敏度达到$1.5 \times 10^{-5}$ s $^{-2}$,仅受几何约束的限制。我们观察到梯度相位对磁场梯度的灵敏度极低,接近比基于碱原子的梯度计的灵敏度低10 $^{5}$倍的值。一个有效的双发射技术采用加速红色垂直晶格从一个单一的磁光阱云也证明。这些结果突出了锶作为精确测量重力梯度的理想候选者,在基础物理学的未来精确测试中具有潜在的应用。
Sr atom interferometry with the optical clock transition as a gravimeter and a gravity gradiometer
我们利用锶原子的$^{1}$ S $_{0}$- $^3$ P $_0$时钟跃迁来表征重力仪和重力梯度仪的性能。我们使用这种新的量子传感器来测量重力加速度的相对灵敏度为$1.7\times10^{-5}$,代表了第一个实现的原子干涉重力仪的基础上的单光子跃迁。各种噪声的重力仪的贡献进行测量和表征,与目前的主要限制灵敏度被视为是固有的噪声的干涉激光本身。在重力梯度仪配置中,在人为引入的$π/2$ ~rad的微分相位下,获得了1.53~rad/ $\sqrt{Hz}$的微分相位灵敏度。我们实验研究的对比度和能见度的影响,基于各种参数,并实现了总的干涉时间为30毫秒,这是比以前报道的这种干涉仪。采用$^{88}$ Sr原子的本装置的表征和确定的限制为未来开发具有碱土和类碱土原子(例如,$^{87}$ Sr、Ca、Yb)。
Phase shift in atom interferometry due to spacetime curvature
我们提出了一个单源双原子干涉仪,并利用它作为一个梯度精确的引力测量。干涉原子波包(大至16厘米)之间的宏观分离揭示了反冲效应和附近铅源质量的引力曲率的相互作用。梯度仪基线由激光波长和脉冲定时设置,可进行高精度测量。使用长漂移时间和大动量转移原子光学,梯度计达到$3 \times 10^{-9}$ s $^{-2}$每次拍摄的分辨率和测量1拉德的源质量引起的相移。
Technical Proposal for the Atom Interferometer CERN Experiment (AICE) Facility
CERN(欧洲核子研究组织);German Aerospace Center (DLR), Institute of Quantum Technologies(德国航空航天中心(DLR)量子技术研究所);Rutherford Appleton Laboratory, UKRI-STFC(卢瑟福·阿普尔顿实验室,英国研究与创新署-科学和技术设施委员会);High Energy Physics Group, Blackett Laboratory, Imperial College(帝国理工学院布莱克特实验室高能物理组);IOGS, LP2N, Université Bordeaux, CNRS, UMR 5298(高等光学研究生院,LP2N,波尔多大学,法国国家科学研究中心,联合研究单位5298);Gravitation Astroparticle Physics Amsterdam (GRAPPA), University of Amsterdam(阿姆斯特丹引力天体粒子物理学(GRAPPA),阿姆斯特丹大学);Institut de Física d’Altes Energies (IFAE), The Barcelona Institute of Science and Technology(高能物理研究所(IFAE),巴塞罗那科学技术研究院);Institució Catalana de Recerca i Estudis Avançats (ICREA)(加泰罗尼亚研究高级学院(ICREA));Department of Physics, University of Oxford(牛津大学物理系);Department of Physics & Astronomy, University College London(伦敦大学学院物理与天文系)
Amplitude Modulation Noise Suppression of Dynamic Atom Gravimeters
Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences(中国科学院武汉物理与数学研究所,精密测量科学与技术创新学院);University of Chinese Academy of Sciences(中国科学院大学);Wuhan Institute of Quantum Technology(武汉量子技术研究院);Hefei National Laboratory(合肥国家实验室)