arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1401.4172astro-ph.CO
收藏

用方差统计量约束再电离时期:LOFAR情况的模拟

Constraining the epoch of reionization with the variance statistic: simulations of the LOFAR case

Ajinkya H. Patil, Saleem Zaroubi, Emma Chapman, Vibor Jelić, Geraint Harker, Filipe B. Abdalla, Khan M. B. Asad, Gianni Bernardi, Michiel A. Brentjens, A. G. de… 展开作者

Ajinkya H. Patil, Saleem Zaroubi, Emma Chapman, Vibor Jelić, Geraint Harker, Filipe B. Abdalla, Khan M. B. Asad, Gianni Bernardi, Michiel A. Brentjens, A. G. de Bruyn, Sander Bus, Benedetta Ciardi, Soobash Daiboo, Elizabeth R. Fernandez, Abhik Ghosh, Hannes Jensen, Sanaz Kazemi, Léon V. E. Koopmans, Panagiotis Labropoulos, Maaijke Mevius, Oscar Martinez, Garrelt Mellema, Andre. R. Offringa, Vishhambhar N. Pandey, Joop Schaye, Rajat M. Thomas, Harish K. Vedantham, Vamsikrishna Veligatla, Stefan J. Wijnholds, Sarod Yatawatta

摘要:

几个实验正在进行中,以检测宇宙红移21厘米的信号,从中性氢的再电离时代(EoR)。由于其非常低的信噪比,这些观测旨在通过测量其功率谱来统计检测信号。我们调查的信号方差的提取作为第一步,对检测和约束的全球历史的EoR。信号方差是信号功率谱的积分,并且期望以高显著性来测量。我们证明了这一点,通过模拟和参数估计管道开发的低频阵列(LOFAR)-EoR实验的结果。我们表明,LOFAR应该能够检测到的EoR在600小时的整合使用方差统计。此外,假设参数化,再电离的红移($z_r$)和持续时间($Δz$)可以被约束。我们使用$z_r = 7.68$和$Δz = 0.43$的EoR模拟来测试流水线。假设系统误差可以得到充分控制,我们能够检测具有4个标准偏差的显著性的模拟信号,并在600小时内提取EoR参数作为$z_r = 7.72^{+0.37}_{-0.18}$和$Δz = 0.53^{+0.12}_{-0.23}$。我们进一步表明,EoR参数的检测和约束的意义,可以提高通过互相关连续的红移箱测量信号的互方差。

英文摘要:

Several experiments are underway to detect the cosmic redshifted 21-cm signal from neutral hydrogen from the Epoch of Reionization (EoR). Due to their very low signal-to-noise ratio, these observations aim for a statistical detection of the signal by measuring its power spectrum. We investigate the extraction of the variance of the signal as a first step towards detecting and constraining the global history of the EoR. Signal variance is the integral of the signal's power spectrum, and it is expected to be measured with a high significance. We demonstrate this through results from a simulation and parameter estimation pipeline developed for the Low Frequency Array (LOFAR)-EoR experiment. We show that LOFAR should be able to detect the EoR in 600 hours of integration using the variance statistic. Additionally, the redshift ($z_r$) and duration ($Δz$) of reionization can be constrained assuming a parametrization. We use an EoR simulation of $z_r = 7.68$ and $Δz = 0.43$ to test the pipeline. We are able to detect the simulated signal with a significance of 4 standard deviations and extract the EoR parameters as $z_r = 7.72^{+0.37}_{-0.18}$ and $Δz = 0.53^{+0.12}_{-0.23}$ in 600 hours, assuming that systematic errors can be adequately controlled. We further show that the significance of detection and constraints on EoR parameters can be improved by measuring the cross-variance of the signal by cross-correlating consecutive redshift bins.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑