arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1312.0743nucl-exphysics.ins-det
收藏

用富集的~(116)CdWO_4晶体闪烁器寻找~(116)Cd的2β衰变

Search for 2β decay of 116Cd with the help of enriched 116CdWO4 crystal scintillators

D. V. Poda, A. S. Barabash, P. Belli, R. Bernabei, F. Cappella, V. Caracciolo, S. Castellano, D. M. Chernyak, R. Cerulli, F. A. Danevich, S. d'Angelo, A. Incicc… 展开作者

D. V. Poda, A. S. Barabash, P. Belli, R. Bernabei, F. Cappella, V. Caracciolo, S. Castellano, D. M. Chernyak, R. Cerulli, F. A. Danevich, S. d'Angelo, A. Incicchitti, V. V. Kobychev, S. I. Konovalov, M. Laubenstein, R. B. Podviyanuk, O. G. Polischuk, V. N. Shlegel, V. I. Tretyak, V. I. Umatov, Ya. V. Vasiliev

摘要:

在INFN(意大利)的Gran Sasso国家实验室,使用富集$^{116}$ Cd至82%的钨酸镉晶体闪烁器($^{116}$ CdWO $_4$,总质量为$\approx$ 1.2 kg)来搜索地下深处的$^{116}$ Cd的2 $β$衰变。对$^{116}$ CdWO $_4$晶体的放射性污染进行了仔细的研究,以重建探测器的本底。测量的$^{116}$ Cd相对于2 $ν$ 2 $β$衰变的半衰期为$T^{2\nu2β}_{1/2}$ = [2.8 $\pm$ 0.05(stat.)$\pm$ 0.4(系统)] $\times$ 10 $^{19}$ yr,与先前实验的结果一致。$^{116}$ Cd的0 $ν$ 2 $β$衰变的所获得的极限(考虑到在能量间隔2.7-2.9 MeV中使用高级本底0.12(2)计数/年/kg/keV的最后8696 h运行的数据)为90% C. L时的$T_{1/2} \ge 1.0 \times 10^{23}$年。实验对$0\nu2β$工艺的灵敏度为90% C. L时的$\lim T_{1/2} = 3 \times 10^{23}$ yr。超过5年的测量,并且对于相同的数据采集周期,它可以被提高(通过将背景进一步降低因子3-30)到$\lim T_{1/2} = (0.5-1.5) \times 10^{24}$ yr的水平。

英文摘要:

Cadmium tungstate crystal scintillators enriched in $^{116}$Cd to 82% ($^{116}$CdWO$_4$, total mass of $\approx$1.2 kg) are used to search for 2$β$ decay of $^{116}$Cd deep underground at the Gran Sasso National Laboratory of the INFN (Italy). The radioactive contamination of the $^{116}$CdWO$_4$ crystals has been studied carefully to reconstruct the background of the detector. The measured half-life of $^{116}$Cd relatively to 2$ν$2$β$ decay is $T^{2\nu2β}_{1/2}$ = [2.8 $\pm$ 0.05(stat.) $\pm$ 0.4(syst.)] $\times$ 10$^{19}$ yr, in agreement with the results of previous experiments. The obtained limit on the 0$ν$2$β$ decay of $^{116}$Cd (considering the data of the last 8696 h run with an advanced background 0.12(2) counts/yr/kg/keV in the energy interval 2.7-2.9 MeV) is $T_{1/2} \ge 1.0 \times 10^{23}$ yr at 90% C.L. The sensitivity of the experiment to the $0\nu2β$ process is $\lim T_{1/2} = 3 \times 10^{23}$ yr at 90% C.L. over 5 years of the measurements and it can be advanced (by further reduction of the background by a factor 3-30) to the level of $\lim T_{1/2} = (0.5-1.5) \times 10^{24}$ yr for the same period of the data taking.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑