Mechanical clocks consist of a pendulum and a clockwork that translates the pendulum period to displayed time. The most advanced clocks utilize optical transitions in atoms in place of the pendulum and an optical frequency comb generated by a femtosecond laser as the clockwork. The comb must be stabilized at two points along its frequency spectrum: one with a laser to lock a comb line to a transition in the atom, and another through self referencing to stabilize the frequency interval between the comb lines. This approach requires advanced techniques, so optical atomic clocks are currently laboratory devices in specialized labs. In this paper we leverage unique properties of Kerr comb oscillators for realization of optical atomic clocks in miniature form factors. In particular, we describe a clock based on D1 transition of 87Rb that fits in the palm of the hand, and can be further miniaturized to chip scale.
We present a joint theoretical and experimental characterization of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. We observe high-contrast transmission resonances (up to 25%), which makes this excitation scheme promising for miniature all-optical atomic clock applications. We also demonstrate cancellation of the first-order light shift by proper choice of the frequencies and relative intensities of the two laser field components. Our theoretical predictions are in good agreement with the experimental results…
We report a frequency measurement of the clock transition of a single ^40Ca^+ ion trapped and laser cooled in a miniature ring Paul trap with 10^-15 level uncertainty. In the measurement, we used an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the Global Positioning System (GPS). Two rounds of measurements were taken in May and June 2011, respectively. The frequency was measured to be 411 042 129 776 393.0(1.6) Hz with a fractional uncertainty of 3.9{\times}10^-15 in a total averaging time of > 2{\times}10^6 s within 32 days.
Ultralow-noise microwave oscillator via optical frequency division with a co-self-injection-locked miniature Fabry-Perot reference
National Innovation Institute of Defense Technology, Academy of Military Sciences PLA China(中国人民解放军军事科学院国防创新研究院);College of Computer Science and Technology, National University of Defense Technology(国防科技大学计算机学院);College of Advanced Interdisciplinary Studies, National University of Defense Technology(国防科技大学前沿交叉学院);College of Science, National University of Defense Technology(国防科技大学理学院);Hunan Research Center of the Basic Discipline for Physical States, National University of Defense Technology(国防科技大学物理状态湖南省基础学科研究中心)
We study the impact of inherent mode coupling between clockwise (CW) and counter-clockwise (CCW) modes on Kerr comb generation in a small whispering-gallery mode microcavity. Our numerical analysis using a coupled Lugiato-Lefever equation reveals the range of the coupling strength in which a soliton pulse can be obtained in the CW direction. It also showed that CCW comb power depends on the coupling strength between the CW and CCW modes. In addition to the simulation, we conducted an experiment to confirm that the power ratio between the CW and CCW comb modes depends on the coupling strength, …
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of $(1-2)\times 10^{-17}$ Hz$^{-1/2}$ at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measuremen…
Optical-frequency combs enable measurement precision at the 20th digit, and accuracy entirely commensurate with their reference oscillator. A new direction in experiments is the creation of ultracompact frequency combs by way of nonlinear parametric optics in microresonators. We refer to these as microcombs, and here we report a silicon-chip-based microcomb optical clock that phase-coherently converts an optical-frequency reference to a microwave signal. A low-noise comb spectrum with 25 THz span is generated with a 2 mm diameter silica disk and broadening in nonlinear fiber. This spectrum is …
Kerr microresonators generate interesting and useful fundamental states of electromagnetic radiation through nonlinear interactions of continuous-wave (CW) laser light. Using photonic-integration techniques, functional devices with low noise, small size, low-power consumption, scalable fabrication, and heterogeneous combinations of photonics and electronics can be realized. Kerr solitons, which stably circulate in a Kerr microresonator, have emerged as a source of coherent, ultrafast pulse trains and ultra-broadband optical-frequency combs. Using the f-2f technique, Kerr combs support carrier-…
The counting and control of optical cycles of light has become common with modelocked laser frequency combs. But even with advances in laser technology, modelocked laser combs remain bulk-component devices that are hand-assembled. In contrast, a frequency comb based on the Kerr-nonlinearity in a dielectric microresonator will enable frequency comb functionality in a micro-fabricated and chip-integrated package suitable for use in a wide-range of environments. Such an advance will significantly impact fields ranging from spectroscopy and trace gas sensing, to astronomy, communications, atomic t…
Rapid characterization of optical and vibrational spectra with high resolution can identify species in cluttered environments and is important for assays and early alerts. In this regard, dual-comb spectroscopy has emerged as a powerful approach to acquire nearly instantaneous Raman and optical spectra with unprecedented resolution. Spectra are generated directly in the electrical domain and avoid bulky mechanical spectrometers. Recently, a miniature soliton-based comb has emerged that can potentially transfer the dual-comb method to a chip platform. Unlike earlier microcombs, these new device…
Ultra-Low-Noise Brillouin Hybrid Synthetic Laser for Sub-Hertz Lattice Clock Spectroscopy
University of California Santa Barbara(加州大学圣塔芭芭拉分校);JILA, National Institute of Standards and Technology and University of Colorado, Boulder(JILA,美国国家标准与技术研究院和科罗拉多大学博尔德分校);Department of Physics, University of Colorado, Boulder(科罗拉多大学博尔德分校物理系);Time and Frequency Division, National Institute of Standards and Technology, Boulder(美国国家标准与技术研究院博尔德时分部)
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $ν_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency comb generator was used to phase-coherently link the optical frequency derived from a single trapped ion to a cesium fountain controlled hydrogen maser. This measurement is one of the most accurate measurements of optical frequencies ever reported, and it represents a contribution to the development of optical clocks based on an $^{171}$Yb$^+$ ion standard.
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously ope…
We report on transferring 1E-16-level fractional frequency stability of a "master laser" operated at 1.5 μm to a "slave laser" operated at 698 nm, using a femtosecond fiber comb as transfer oscillator. With the 698 nm laser, the 1S_0 - 3P_0 clock transition of 87Sr was resolved to a Fourier-limited line width of 1.5 Hz (before: 10 Hz). Potential noise sources contributed by the frequency comb are discussed in detail.
Laser spectroscopy of the $^{\mathrm{229m}}$Th nuclear clock transition is necessary for the future construction of a nuclear-based optical clock. Precision laser sources with broad spectral coverage in the vacuum ultraviolet are needed for this task. Here, we present a tunable vacuum-ultraviolet frequency comb based on cavity-enhanced seventh-harmonic generation. Its tunable spectrum covers the current uncertainty range of the $^{\mathrm{229m}}$Th nuclear clock transition.
We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved stability of the clock laser at 698 nm enabled us to evaluate the systematic frequency shifts of the Sr optical lattice clock with shorter averaging time. We determined the absolute frequency of the clock transition 1S0 - 3P0 in 87Sr to be 429 228 004 229 873.9 (1.4) Hz referenced to the SI second on the geoid via International Atomic Time (TAI).
Future optical clock networks will require free-space optical time-frequency transfer between flying clocks. However, simple one-way or standard two-way time transfer between flying clocks will completely break down because of the time-of-flight variations and Doppler shifts associated with the strongly time-varying optical link distances. Here, we demonstrate an advanced, comb-based optical two-way time-frequency transfer that can successfully synchronize the optical timescales at two sites connected via a time-varying turbulent air path. The link between the two sites is established using ei…
This letter presents the principles and techniques of active optical clock, a special laser combining the laser physics of one-atom laser, bad-cavity gas laser, super-cavity stabilized laser and optical atomic clock. As an example, a compact version of active optical clock based on thermal Strontium atomic beam shows a quantum-limited linewidth of 0.51 Hz, which is insensitive to laser cavity-length noise, and may surpass the recorded narrowest 6.7 Hz of Hg ion optical clock and 27Hz of very recent optical lattice clock. The estimated 0.1Hz one-second instability and 0.27Hz uncertainty are lim…
Laser frequency combs based on erbium-doped fiber mode-locked lasers have shown great potential for compact, robust and efficient optical clock comparisons. However, to simultaneously compare multiple optical clock species, fiber laser frequency combs typically require multiple amplifiers and fiber optic paths that reduce the achievable frequency stability near 1 part in $10^{16}$ at 1s. In this paper we describe an erbium-fiber laser frequency comb that overcomes these conventional challenges and supports optical frequency synthesis at the millihertz level, or fractionally $3 x 10^{-18}$ $tau…
We have developed a universal method to form the reference signal for the stabilization of arbitrary atomic clocks based on Ramsey spectroscopy. Our approach uses an interrogation scheme of the atomic system with two different Ramsey periods and a specially constructed combined error signal (CES) computed by subtracting two error signals with the appropriate calibration factor. CES spectroscopy allows for perfect elimination of probe-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors and other imperfection…
Frequency microcombs, successors to mode-locked laser and fiber combs, enable miniature rulers of light for applications including precision metrology, molecular fingerprinting, and exoplanet discoveries. To enable the frequency ruling function, microcombs must be stabilized by locking their carrier-envelop offset frequency. So far, the microcomb stabilization remains compounded by the elaborate optics external to the chip, thus evading its scaling benefit. To address this challenge, here we demonstrate a nanophotonic chip solution based on aluminum nitride thin films, which simultaneously off…
Heterodyne laser phase measurements in a space-based gravitational wave interferometer are degraded by the phase fluctuations of the onboard clocks, resulting in unacceptable sensitivity performance levels of the interferometric data. In order to calibrate out the clock phase noises it has been previously suggested that additional inter-spacecraft phase measurements must be performed by modulating the laser beams. This technique, however, considerably increases system complexity and probability of subsystem failure. With the advent of self-referenced optical frequency combs, it is possible to …
With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic shifts (20 Hz uncertainty) in the absolute frequency measurement of 429 228 004 229 867 Hz. The high resolution permits an investigation of the optical lattice motional sideband structure. The local oscillator for this optical atomic clock is a stable diode laser with its Hz-level linewidth characterized across the optical spectrum using a femtosecond frequency…
We stabilise a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fibre-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb we measure independently the instability of the microwave source with respect to another optical clock laser frequency at 456 THz. The total fractional frequency instability of this optic-to-microwave and microwave-to-optic conversion resulted in an Allan deviation sigma_y, of sigma_y=1.2E-14 at 1 s averaging time (band width 50 kHz). The residual phase noise density is -97 dBc/Hz at 10 Hz offset from …
The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We find the transition frequencies to be f_Hg=1 064 721 609 899 143(10) Hz and f_Ca=455 986 240 494 158(26) Hz, respectively. In addition to the unprecedented precision demonstrated here, this work is the precursor to all-optical atomic clocks based on the Hg^+ and Ca standards. Furthermore, when combined with previous measurements, we find no time variations of …
Laboratory optical atomic clocks achieve remarkable accuracy (now counted to 18 digits or more), opening possibilities to explore fundamental physics and enable new measurements. However, their size and use of bulk components prevent them from being more widely adopted in applications that require precision timing. By leveraging silicon-chip photonics for integration and to reduce component size and complexity, we demonstrate a compact optical-clock architecture. Here a semiconductor laser is stabilized to an optical transition in a microfabricated rubidium vapor cell, and a pair of interlocke…
Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experi…
We present non-standard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties of Ramsey fringes can be radically suppressed (by 2-4 orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly ben…
We develop a nonstandard concept of atomic clocks where the blackbody radiation shift (BBRS) and its temperature fluctuations can be dramatically suppressed (by one to three orders of magnitude) independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies v1 and v2) which are exposed to the same thermal environment, there exists a "synthetic" frequency v_{syn} (v1-e12 v2) largely immune to the BBRS. As an example, it is shown that in the case of ion 171Yb+ it is possible to create a clock in which th…
We present a compact, long-term nearly continuous operation of a room-temperature Ca$^+$ optical clock setup towards a transportable clock, achieving an overall systematic uncertainty of $4.8\times 10^{-18}$ and an uptime rate of 97.8% over an 8-day period. The active liquid-cooling scheme is adopted, combined with the precise temperature measurement with 13 temperature sensors both inside and outside the vacuum chamber to ensure the accurate evaluation of the thermal environment for the optical clock. The environmental temperature uncertainty is evaluated as 293.31(0.4) K, corresponding to a …
We propose a new frequency standard based on a $4f^{14} 6s6p~ ^3\!P_0 - 4f^{13} 6s^2 5d ~(J=2)$ transition in neutral Yb. This transition has a potential for high stability and accuracy and the advantage of the highest sensitivity among atomic clocks to variation of the fine-structure constant $α$. We find its dimensionless $α$-variation enhancement factor to be $K=-15$, in comparison to the most sensitive current clock (Yb$^+$ E3, $K=-6$), and it is 18 times larger than in any neutral-atomic clocks (Hg, $K=0.8$). Combined with the unprecedented stability of an optical lattice clock for neutra…