arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1211.0909astro-ph.IMnucl-exphysics.ins-det
收藏

DEAP-1液氩基暗物质探测器中的氡本底

Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

P. -A. Amaudruz, M. Batygov, B. Beltran, K. Boudjemline, M. G. Boulay B. Cai T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Contreras, K. Dering, F. Du… 展开作者

P. -A. Amaudruz, M. Batygov, B. Beltran, K. Boudjemline, M. G. Boulay B. Cai T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Contreras, K. Dering, F. Duncan, R. Ford, R. Gagnon F. Giuliani, M. Gold V. V. Golovko, P. Gorel, K. Graham, D. R. Grant, R. Hakobyan, A. L. Hallin, P. Harvey, C. Hearns, C. J. Jillings, M. Kuźniak, I. Lawson, O. Li, J. Lidgard, P. Liimatainen, W. H. Lippincott, R. Mathew, A. B. McDonald, T. McElroy, K. McFarlane, D. McKinsey, A. Muir, C. Nantais, K. Nicolics, J. Nikkel, T. Noble, E. O'Dwyer, K. S. Olsen, C. Ouellet, P. Pasuthip, T. Pollmann, W. Rau, F. Retiere, M. Ronquest, P. Skensved, T. Sonley, J. Tang, E. Vázquez-Jáuregui, L. Veloce, M. Ward

摘要:

DEAP-1 \SI{7}{kg}单相液氩闪烁探测器在SNOLAB地下运行,以测试技术和测量单相探测固有的背景,以支持\mbox{DEAP-3600}暗物质探测器。通过材料选择、构造技术、脉冲形状识别和同相轴重建来控制DEAP中的背景。本报告详细分析了在DEAP-1探测器的三次迭代中观察到的背景事件,以及为减少这些事件而采取的措施。测得$^{222}$ Rn在液氩中的衰变率在16和\SI{26}{\micro\becquerel\per\kilogram}之间。我们发现,在DEAP-1探测器中用于暗物质探测的感兴趣区域附近的背景光谱可以通过考虑来自三个源的事件来描述:氡子体在活性体积的表面上衰减,由于脉冲形状辨别的效率低下而将电磁事件的预期速率误认为核反冲,以及由于不完美的位置重建而导致事件从基准体积外部泄漏。这些背景在统计上解释了所有观测到的事件,并且由于其更高的光输出和更简单的几何结构,它们将在DEAP-3600探测器中大大减少。

英文摘要:

The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑