arXiv 1704.01882astro-ph.IMphysics.ins-det
收藏

TPB波长转换器在DEAP-3600球形丙烯酸酯容器内表面的应用

Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface

B. Broerman, M. G. Boulay, B. Cai, D. Cranshaw, K. Dering, S. Florian, R. Gagnon, P. Giampa, C. Gilmour, C. Hearns, J. Kezwer, M. Kuźniak, T. Pollmann, M. Ward

摘要:

DEAP-3600使用装在球形丙烯酸容器中的液态氩作为目标介质,进行灵敏的自旋无关暗物质搜索。氩在真空紫外光谱中发光,这需要波长移动以将VUV光子转换为可见光,以便它们可以通过丙烯酸光导传输并被周围的光电倍增管检测到。在真空下将波长移动剂1,1,4,4-四苯基-1,3-丁二烯蒸发沉积到丙烯酸类容器的内表面。在DEAP-3600丙烯酸容器上进行两次蒸发,估计涂层厚度为3.00 $\pm$ ± 0.02 $μ$ m,其在检测器中成功地用液态氩进行波长偏移。详细介绍了波长移位器涂层的要求,沉积源,测试和最终性能。

英文摘要:

DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a target medium to perform a sensitive spin-independent dark matter search. Argon scintillates in the vacuum ultraviolet spectrum, which requires wavelength shifting to convert the VUV photons to visible so they can be transmitted through the acrylic light guides and detected by the surrounding photomultiplier tubes. The wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene was evaporatively deposited to the inner surface of the acrylic vessel under vacuum. Two evaporations were performed on the DEAP-3600 acrylic vessel with an estimated coating thickness of 3.00 $\pm$ 0.02 $μ$m which is successfully wavelength shifting with liquid argon in the detector. Details on the wavelength shifter coating requirements, deposition source, testing, and final performance are presented.