费米国家加速器实验室正在新μ子实验室建造一个先进的加速器研究和开发设施。支持该设施初始阶段的低温基础设施包括两台Tevatron式独立制冷机、低温分配系统以及一个环境温度泵送系统,以实现2 K操作和支持净化系统。在项目的这一阶段,安装了一个III型加1.3 GHz的低温恒温器,进行了冷却和测试。低温恒温器的设计约束要求低温恒温器的各个回路以预定速率冷却。这些限制需要特殊的设计解决方案来实现。本文介绍了使用新μ子实验室低温系统的1.3 GHz低温恒温器的初始冷却和运行经验。

英文摘要:

Fermi National Accelerator Laboratory is constructing an Advanced Accelerator Research and Development facility at New Muon Lab. The cryogenic infrastructure in support of the initial phase of the facility consists of two Tevatron style standalone refrigerators, cryogenic distribution system as well as an ambient temperature pumping system to achieve 2 K operations with supporting purification systems. During this phase of the project a single Type III plus 1.3 GHz cryomodule was installed, cooled and tested. Design constraints of the cryomodule required that the cryomodule individual circuits be cooled at predetermined rates. These constraints required special design solutions to achieve. This paper describes the initial cooldown and operational experience of a 1.3 GHz cryomodule using the New Muon Lab cryogenic system.