arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1206.6199physics.ins-dethep-ex
收藏

NEXT-DEMO的SiPM跟踪系统的设计和表征,它是NEXT-100实验的演示样机

Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment

NEXT Collaboration, V. Álvarez, M. Ball, F. I. G. M. Borges, S. Cárcel, J. M. Carmona, J. Castel, J. M. Catalá, S. Cebrián, A. Cervera, D. Chan, C. A. N. Conde,… 展开作者

NEXT Collaboration, V. Álvarez, M. Ball, F. I. G. M. Borges, S. Cárcel, J. M. Carmona, J. Castel, J. M. Catalá, S. Cebrián, A. Cervera, D. Chan, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. Ferrer-Ribas, E. D. C. Freitas, A. N. C. Garcia, V. M. Gehman, A. Gil, I. Giomataris, A. Goldschmidt, H. Gómez, J. J. Gómez-Cadenas, K. González, D. González-Díaz, R. M. Gutiérrez, J. Hauptman, J. A. Hernando Morata, D. C. Herrera, V. Herrero, F. J. Iguaz, I. G. Irastorza, V. Kalinnikov, D. Kiang, L. Labarga, I. Liubarsky, J. A. M. Lopes, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, T. Miller, A. Moiseenko, F. Monrabal, C. M. B. Monteiro, J. M. Monzó, F. J. Mora, L. M. Moutinho, J. Muñoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot, D. Nygren, C. A. B. Oliveira, R. Palma, J. Pérez, J. L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F. P. Santos, J. M. F. dos Santos, L. Segui, L. Serra, D. Shuman, C. Sofka, M. Sorel, J. F. Toledo, A. Tomás, J. Torrent, Z. Tsamalaidze, D. Vázquez, E. Velicheva, J. F. C. A. Veloso, J. A. Villar, R. C. Webb, T. Weber, J. White, N. Yahlali

摘要:

NEXT-100实验的目的是使用装有100公斤高压气态氙的TPC(同位素富集度为90%)研究氚-136同位素的无中微子双β衰变。该实验将在西班牙Canfranc Subterráneo(LSC)进行。NEXT-100采用电致发光(EL)技术进行能量测量,分辨率优于1% FWHM。TPC中的气态氙还允许记录两个β粒子的径迹,预计在10巴压力下的径迹长度可达30厘米。记录无中微子双β事件的拓扑特征的能力为双β实验提供了强有力的背景抑制因子。在本文中,我们提出了一种新颖的3D成像概念,使用涂有四苯基丁二烯(TPB)的SiPM进行EL读出,并在NEXT-DEMO(NEXT-100实验的大规模原型)中首次实现。介绍了NEXT-DEMO SiPM跟踪系统的设计和首次表征测量。从其增益图绘制的跟踪平面上的SiPM响应均匀性被示出为优于4%。基于增益漂移的电源电压补偿,研制了一种用于稳定SiPM增益的自动主动控制系统。增益被证明是稳定在0.2%的相对变化,其标称值,由滨松,在10摄氏度的温度范围内。来自电子器件和SiPM暗噪声的噪声水平通常低于ADC中10个光电子(pe)的水平。因此,为捕获跟踪信号设置了10 pe的检测阈值。ADC的全动态范围(4096通道)被证明是足够的信号电平高达200 pe/微秒,这使得记录大多数的跟踪信号。

英文摘要:

NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the neutrinoless double-beta events provides a powerful background rejection factor for the double-beta experiment. In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degree C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/microsecond, which enables recording most of the tracking signals.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑