Purpose: To improve the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans.
Methods and materials: A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of partial-arc plans is created by searching the space of all possible partial-arc plans that satisfy these constraints. For each partial-arc, an iterative fluence map merging and sequencing algorithm (vmerge) is used to improve the delivery efficiency. Merging continues as long as the dose quality is maintained above a user-defined threshold. The final plan is selected as the partial arc with the lowest treatment time. The complete algorithm is called pmerge.
Results: Partial-arc plans are created using pmerge for a lung, liver and prostate case, with final treatment times of 127, 245 and 147 seconds. Treatment times using full arcs with vmerge are 211, 357 and 178 seconds. Dose quality is maintained across the initial, vmerge, and pmerge plans to within 5% of the mean doses to the critical organs-at-risk and with target coverage above 98%. Additionally, we find that the angular distribution of fluence in the initial plans is predictive of the start and end angles of the optimal partial-arc.
Conclusions: The pmerge algorithm is an extension to vmerge that automatically finds the partial-arc plan that minimizes the treatment time. VMAT delivery efficiency can be improved by employing partial-arcs without compromising dose quality. Partial arcs are most applicable to cases with non-centralized targets, where the time savings is greatest.
Automatizing a non-scripting TPS for optimizing clinical workflow and re-optimization of IMRT/VMAT plans
设计了用于与Elekta Monaco(Clements et al 2018)治疗计划系统(TPS)交互的工具包,无需专用应用程序编程接口(API)。它提供了放射治疗计划程序的自动化,允许TPS在非工作时间计算或优化计划。该软件基于一个开源库,模仿人类与Microsoft Windows应用程序的交互。对临床工作流程的影响非常重要,不仅可以提供更好的效率,还可以提高治疗质量。成功的逆向规划取决于许多参数的调整,这些参数可以使用此工具进行更详尽的探索,而不会显着增加规划时间。此外,一个简单的方法来分析计算的计划和成本函数的影响,在优化已经实施。Autoflow序列已经开发出来,允许完全自动化的计划;它可以分析优化中不同成本函数的相对影响,并相应地修改约束。它还更改分割参数以适应更复杂的治疗。已经进行了一项前列腺研究,将自动创建的计划与已经治疗的计划进行比较。Autoflow序列已被证明可减少危及器官的剂量,而靶区覆盖率的降低可忽略不计。实施该工具可以有效使用TPS,使研究和临床使用以友好的方式共存。它在资源很少的诊所肯定有很大的用处。它在整个治疗计划过程中提供一致性和效率。
A volumetric Modulated Arc Therapy (VMAT) combined with deep inspiration breath hold (DIBH) technique for adjuvant irradiation for left sided breast cancer
Fully Automated Treatment Planning for Head and Neck Radiotherapy using a Voxel-Based Dose Prediction and Dose Mimicking Method
最近在自动放射治疗计划中的工作已经使用基于历史治疗计划的机器学习来直接从计划图像推断新患者的空间剂量分布。我们提出了一种基于图谱的方法,该方法在训练数据库中学习每个患者的剂量预测模型(图谱),然后学习将新患者与最相关的图谱相匹配。该方法创建空间剂量目标,其指定期望的每体素剂量,并且因此取代指定剂量体积目标的任何要求,以传达治疗计划的目标。概率剂量分布从最相关的图谱中推断,并使用条件随机场进行定标,以确定最可能的剂量空间分布,从而为相关的感兴趣区域产生特定的剂量先验(直方图)。然后,基于体素的剂量模拟将预测的剂量分布转换为可递送的治疗计划剂量分布。在这项研究中,我们研究了接受IMRT和VMAT治疗的右侧orbiliaynx头颈部患者的自动计划。我们使用54个训练和12个独立测试患者的数据库比较了我们的剂量预测管道的四个版本。我们的初步结果是有希望的;与临床相比,自动计划在7例患者中实现了更多的剂量评价标准,在4例患者中实现了相同数量的剂量评价标准。总体而言,自动化计划达到的标准相对数量高于临床(17 vs 8),自动化计划显示出对风险器官的保留增加(52 vs 44)和更好的靶覆盖/均匀性(41 vs 31)。
Divergent Clinical Equivalence Findings from DVH and NTCP Metrics for Alternative OAR Delineations with Increasing Setup Variability in Head-and-Neck Radiotherapy
Simultaneous optimization of non-coplanar beam orientations and cumulative EQD2 distribution for high-dose reirradiation of locoregionally recurrent non-small cell lung cancer
Department of Radiation Oncology, University Hospital Zurich and University of Zurich(苏黎世大学医院和苏黎世大学放射肿瘤科);Department of Medical Physics, Memorial Sloan Kettering Cancer Center(纪念斯隆-凯特琳癌症中心医学物理系)