Precise Stellar Radial Velocities of an M Dwarf with a Michelson Interferometer and a Medium-resolution Near-infrared Spectrograph
Philip S. Muirhead, Jerry Edelstein, David J. Erskine, Jason T. Wright, Matthew W. Muterspaugh, Kevin R. Covey, Edward H. Wishnow, Katherine Hamren, Phillip And… 展开作者
Philip S. Muirhead, Jerry Edelstein, David J. Erskine, Jason T. Wright, Matthew W. Muterspaugh, Kevin R. Covey, Edward H. Wishnow, Katherine Hamren, Phillip Andelson, David Kimber, Tony Mercer, Samuel P. Halverson, Andrew Vanderburg, Daniel Mondo, Agnieszka Czeszumska, James P. Lloyd
备注:
55 pages and 13 figures in aastex format. Accepted by PASP
Precise near-infrared radial velocimetry enables efficient detection and transit verification of low-mass extrasolar planets orbiting M dwarf hosts, which are faint for visible-wavelength radial velocity surveys. The TripleSpec Exoplanet Discovery Instrument, or TEDI, is the combination of a variable-delay Michelson interferometer and a medium-resolution (R=2700) near-infrared spectrograph on the Palomar 200" Hale Telescope. We used TEDI to monitor GJ 699, a nearby mid-M dwarf, over 11 nights spread across 3 months. Analysis of 106 independent observations reveals a root-mean-square precision of less than 37 m/s for 5 minutes of integration time. This performance is within a factor of 2 of our expected photon-limited precision. We further decompose the residuals into a 33 m/s white noise component, and a 15 m/s systematic noise component, which we identify as likely due to contamination by telluric absorption lines. With further development this technique holds promise for broad implementation on medium-resolution near-infrared spectrographs to search for low-mass exoplanets orbiting M dwarfs, and to verify low-mass transit candidates.
Development of Fiber Fabry-Perot Interferometers as Stable Near-infrared Calibration Sources for High Resolution Spectrographs
我们讨论了单模光纤法布里-珀罗(FFP)干涉仪作为高精度径向速度(RV)光谱仪的精确天文光子校准源的持续发展。FFP是简单、廉价的单片单元,可以产生稳定和可重复的输出光谱。FFP是传统标准具的独特替代品,因为干涉腔由单模光纤而不是气隙间隔器制成。这种设计允许出色的准直,高光谱精细度,刚性机械稳定性,对振动不敏感,并且不需要真空操作。我们测试的设备是Micron Optics的市售产品。我们的发展道路是针对校准源的可扩展区行星光谱仪(HPF),近红外光谱仪,旨在检测低质量恒星周围的地球质量行星,但这个参考也可以用于许多现有的和计划中的光纤光谱仪,因为我们说明使用Apache点天文台星系演化实验(APOGEE)仪器。通过对光纤标准具的精确温度控制,我们实现了100 $μ$ K的热稳定性和22 cm s $^{-1}$的相关速度不确定性。我们实现了$\approx$ 2 m s $^{-1}$的精度在一个单一的APOGEE光纤超过12小时,使用这个新的光子参考后,删除系统的相关性。这种高精度(接近预期的光子极限下限)证明了光纤干涉仪出色的固有波长稳定性和APOGEE仪器设计的稳定性。当在所有300个APOGEE光纤上取平均值并去除已知趋势和压力相关性后,12小时内的总体仪器速度精度为80 cm s $^{-1}$,这意味着光纤标准具在本质上稳定到显著更高的精度。