arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1101.4570astro-ph.SR
收藏

太阳和选定的晚型星一维模型中性和单电离铁谱线的非LTE研究

A non-LTE study of neutral and singly-ionized iron line spectra in 1D models of the Sun and selected late-type stars

L. Mashonkina, T. Gehren, J. -R. Shi, A. J. Korn, F. Grupp

摘要:

本文提出了一个具有3000多个能级的铁原子模型。作为该模型原子的一个测试和首次应用,我们用已确定的恒星参数和高质量的观测光谱确定了太阳和五颗恒星的Fe丰度。Non-LTE导致Fe I谱线的系统性总吸收耗尽,并导致与先前研究一致的正丰度校正,然而,与先前的结果相比,non-LTE效应的幅度较小。对于太阳金属丰度和轻度金属缺乏的恒星,非LTE修正不超过0.1 dex,而对于非常缺乏金属的恒星HD 84937和HD 122563,它们的变化范围分别在0.21 dex和0.35 dex之内,这取决于假设的与氢原子碰撞的效率。基于对这两颗恒星的Fe I/Fe II电离平衡的分析,我们建议在Fe的非LTE研究中采用Drawin形式,标度因子为0.1。对于Fe II线,非LTE校正的绝对值不超过0.01 dex。从54条Fe I线获得的太阳非LTE丰度为7.56 ± 0.09,从18条Fe II线获得的丰度在7.41 ± 0.11和7.56 ± 0.05之间变化,取决于gf值的来源。因此,铁谱线的gf值不够精确,无法进行高精度绝对丰度测定。Fe I线的平均丰度比HD 61421和HD 102870的Fe II线低0.1 dex,即使在相对于太阳进行微分分析时也是如此。Fe I和Fe II之间的差距指向恒星大气建模或/和有效温度测定的问题。

英文摘要:

A comprehensive model atom for Fe with more than 3000 energy levels is presented. As a test and first application of this model atom, Fe abundances are determined for the Sun and five stars with well determined stellar parameters and high-quality observed spectra. Non-LTE leads to systematically depleted total absorption in the Fe I lines and to positive abundance corrections in agreement with the previous studies, however, the magnitude of non-LTE effect is smaller compared to the earlier results. Non-LTE corrections do not exceed 0.1 dex for the solar metallicity and mildly metal-deficient stars, and they vary within 0.21 dex and 0.35 dex in the very metal-poor stars HD 84937 and HD 122563, respectively, depending on the assumed efficiency of collisions with hydrogen atoms. Based on the analysis of the Fe I/Fe II ionization equilibrium in these two stars, we recommend to apply the Drawin formalism in non-LTE studies of Fe with a scaling factor of 0.1. For the Fe II lines, non-LTE corrections do not exceed 0.01 dex in absolute value. The solar non-LTE abundance obtained from 54 Fe I lines is 7.56+-0.09 and the abundance from 18 Fe II lines varies between 7.41+-0.11 and 7.56+-0.05 depending on the source of the gf-values. Thus, gf-values available for the iron lines are not accurate enough to pursue high-accuracy absolute abundance determinations. Lines of Fe I give, on average, a 0.1 dex lower abundance compared to those of Fe II lines for HD 61421 and HD 102870, even when applying a differential analysis relative to the Sun. A disparity between Fe I and Fe II points to problems of stellar atmosphere modelling or/and effective temperature determination.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑