arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1101.1285astro-ph.HEastro-ph.COastro-ph.SR
收藏

测量伽马射线暴Epeak的总误差

The Total Errors In Measuring Epeak for Gamma-Ray Bursts

Andrew C. Collazzi, Bradley E. Schaefer, Jeremy A. Moree

摘要:

虽然Epeak在过去被广泛使用,例如与光度指示器一起使用,但尚未彻底检查可能的散射源。在文献中,Epeak的报告误差线是简单的泊松统计误差。由于分析师在确定Epeak时所做的选择(例如,积分的开始和停止时间)、对检测器响应的不完全了解、各种检测器的不同能量范围以及用于拟合光谱的模型的差异。我们检查这些单独的散射源的大小,通过比较许多独立的对公布的Epeak值相同的突发。事实上,在同一爆发的多个报告中观察到的分散(通常具有相同的数据)远远大于公布的统计误差条。我们测量出与分析师的选择相关的一西格玛不确定性为28%,即,0.12在Log 10(Epeak)中,结果误差始终存在。与探测器响应相关的误差小得可以忽略。由Epeak的常用替代定义(例如存在于所有论文和所有编译的突发列表中)引起的变化通常为23%-46%,尽管这随应用而变化很大。这意味着:(1)即使是最好的测量Epeak值也会有28%的系统不确定性。(2)因此,伽马射线暴对于单个事件的精确度是有限的,这可以通过对许多暴进行平均来减少。(3)典型的一西格玛总不确定性的突发集合是55%。(4)我们还发现,在暴帧Epeak的分布宽度必须接近零,这意味着一定存在某种机制恒温伽玛暴。(5)我们的社区只能通过使用具有相同Epeak计算定义的突发集合来改善这种情况。

英文摘要:

While Epeak has been extensively used in the past, for example with luminosity indicators, it has not been thoroughly examined for possible sources of scatter. In the literature, the reported error bars for Epeak are the simple Poisson statistical errors. Additional uncertainties arise due to the choices made by analysts in determining Epeak (e.g., the start and stop times of integration), imperfect knowledge of the response of the detector, different energy ranges for various detectors, and differences in models used to fit the spectra. We examine the size of these individual sources of scatter by comparing many independent pairs of published Epeak values for the same bursts. Indeed, the observed scatter in multiple reports of the same burst (often with the same data) is greatly larger than the published statistical error bars. We measure that the one-sigma uncertainty associated with the analyst's choices is 28%, i.e., 0.12 in Log10(Epeak), with the resultant errors always being present. The errors associated with the detector response are negligibly small. The variations caused by commonly-used alternative definitions of Epeak (such as present in all papers and in all compiled burst lists) is typically 23%-46%, although this varies substantially with the application. The implications of this are: (1) Even the very best measured Epeak values will have systematic uncertainties of 28%. (2) Thus, GRBs have a limitation in accuracy for a single event, with this being reducible by averaging many bursts. (3) The typical one-sigma total uncertainty for collections of bursts is 55%. (4) We also find that the width of the distribution for Epeak in the burst frame must be near zero, implying that some mechanism must exist to thermostat GRBs. (5) Our community can only improve on this situation by using collections of bursts which all have identical definitions for the Epeak calculation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑