arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1101.0224physics.ins-dethep-ex
收藏

LMPRC信号串扰和传输的波束测试

Beam test of signal cross-talk and transmission for LMPRC

Yongjie sun, Cheng Li, Zebo Tang, Lailin Xu, Tianxiang Chen, Ming Shao

摘要:

研制了一种大面积长读出带多间隙电阻板室(MRPC)样机。这种长条形多间隙电阻板室(LMRPC)是双层堆叠的,有10个250 $μ$ m厚的气体间隙。从条带的两端读出信号,条带的有效面积为50 cm $\times$,每个末端2.5 cm。探测器在GSI的FOPI进行了测试,使用质子束($E = 3.5 GeV$)与铅靶碰撞的次级粒子。实验结果表明,LMRPC样机的时间分辨率为60 $\sim$ ~ 70 ps,探测效率大于98%,串扰小于2%.该探测器还具有良好的空间分辨率为0.36厘米沿条带方向。

英文摘要:

A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $μ$m-thick gas gaps. Signals are read out from two ends of strip with an active area of 50 cm$\times$2.5 cm in each. The detector was tested at FOPI in GSI, using the secondary particles of proton beams ($E = 3.5 GeV$) colliding with a Pb target. The results show that the LMRPC prototype has a time resolution of about 60$\sim$70 ps; the detecting efficiency is over 98% and the ratio of cross-talk is lower than 2%. The detector also has a good spatial resolution of 0.36 cm along the strip direction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑