PSI operates a cyclotron based high intensity proton accelerator routinely at an average beam power of 1.3MW. With this power the facility is at the worldwide forefront of high intensity proton accelerators. The beam current is practically limited by losses at extraction and the resulting activation of accelerator components. Further intensity upgrades and new projects aiming at an even higher average beam power, are only possible if the relative losses can be lowered in proportion, thus keeping absolute losses at a constant level. Maintaining beam losses at levels allowing hands-on maintenance is a primary challenge in any high power proton machine design and operation. In consequence, predicting beam halo at these levels is a great challenge and will be addressed in this paper. High power hadron driver have being used in many disciplines of science and, a growing interest in the cyclotron technology for high power hadron drivers are being observed very recently. This report will briefly introduce OPAL, a tool for precise beam dynamics simulations including 3D space charge. One of OPAL's flavors (OPAL-cycl) is dedicated to high power cyclotron modeling and is explained in greater detail. We then explain how to obtain initial conditions for our PSI Ring cyclotron which still delivers the world record in beam power of 1.3 MW continuous wave (cw). Several crucial steps are explained necessary to be able to predict tails at the level of 3σ... 4σin the PSI Ring cyclotron. We compare our results at the extraction with measurements, obtained with a 1.18 MW cw production beam. Based on measurement data, we develop a simple linear model to predict beam sizes of the extracted beam as a function of intensities and confirm the model with simulations.
Effective and accurate computer simulations are highly important in accelerator design and production. The most difficult and important task in cyclotron development is magnetic field simulations. It is necessary to achieve the accuracy of the model that is higher than the tolerance for the magnetic field in the real magnet. An accurate model of the magnet and other systems of the cyclotron allows us to perform beam tracking through the whole accelerator from the ion source to extraction. While high accuracy is necessary in the late stages of research and development, high performance of the s…
In recent years, the interest in high intensity proton beams in excess of several milli-Amperes has risen. Potential applications are in neutrino physics, materials and energy research, and isotope production. Continuous wave proton beams of five to ten milli-Amperes are now in reach due to advances in accelerator technology and through improved understanding of the beam dynamics. As an example application, we present the proposed IsoDAR experiment, a search for so-called sterile neutrinos and non-standard interaction using the KamLAND detector located in Japan. We present updated sensitivitie…
The IsoDAR collaboration is developing a high-current cyclotron for a neutrino search experiment. Designed to deliver 10 mA of 60 MeV protons, the current and power of this cyclotron far exceed those of existing accelerators, opening new possibilities for the production of radiopharmaceutical isotopes, producing very high-activity samples in very short times. The cyclotron can also be easily configured to deliver ions other than protons including 1 mA of alpha particles at 240 MeV: this flexibility gives a broad reach into new areas of isotope production. We explain how IsoDAR overcomes the be…
There is great need for high intensity proton beams from compact particle accelerators in particle physics, medical isotope production, and materials- and energy-research. To address this need, we present, for the first time, a design for a compact isochronous cyclotron that will be able to deliver 10 mA of 60 MeV protons - an order of magnitude higher than on-market compact cyclotrons and a factor four higher than research machines. A key breakthrough is that vortex motion is incorporated in the design of a cyclotron, leading to clean extraction. Beam losses on the septa of the electrostatic …
Beam Dynamics Simulation for the High Intensity DAEδALUS Cyclotrons
在DAEδALUS(Decay-At-rest Experiment for δCP studies At the Laboratory for Underground Science)项目中,提出了高功率H+2回旋加速器链,以有效地提供动能为800 MeV、平均功率在MW范围内的质子束。空间电荷在注入器和环形回旋加速器中都发挥着关键作用。大规模粒子模拟表明,注入器回旋加速器是一种空间电荷主导的回旋加速器,并且可以在隔膜上以可容忍的束流损失提取5 mA的束流电流。相比之下,在环形回旋加速器,没有空间电荷引起的束流损失期间观察到加速和提取。
In this document we present the calculation and experimental validation of a source term for ${}^{18}$F-production with a cyclotron for medical applications operating at 18 MeV proton energy and 30 $μ$A proton current. The Monte Carlo codes MCNP6 and FLUKA were used for the calculation of the source term. In addition, the radiation field around the $^{18}$O-enriched water target was simulated with the two codes. To validate the radiation field obtained in the simulation, an experimental program has been started using activation samples which are placed close to the water target during an ${}^{…
The determination of relative stopping power (RSP) via proton computed tomography (pCT) of a patient is dependent in part on the knowledge of the incoming proton kinetic energies; the uncertainty in these energies is in turn determined by the proton source -- typically a cyclotron. Here we show that reducing the incident proton beam energy spread may significantly improve RSP determination in pCT. We demonstrate that the reduction of beam energy spread from the typical 1.0% (at 70MeV) down to 0.2%, can be achieved at the proton currents needed for imaging at the Paul Scherrer Institut 230MeV c…
This paper presents the magnetic design of a 100MeV Separated Sector Medical Cyclotron (SSMC) as well as the optimization of the injection line magnets where will be used to transport the 14MeV proton beam from the Azimuthally Varying Field (AVF) cyclotron to the SSMC. The study demonstrates that the isochronous magnetic field with a tolerance around 10-4 T can be obtained all along prescribed path by placing three sets of correction trim coils in the pole tips. The result of Betatron oscillations is sufficient to verify that the focusing forces of the magnetic field can hold particles close t…
IsoDAR is a novel experiment designed to measure neutrino oscillations through $\barν_e$ disappearance, thus providing a definitive search for sterile neutrinos. In order to generate the necessary anti-neutrino flux, a high intensity primary proton beam is needed. In IsoDAR, $\mathrm{H}_2^+$ is accelerated and is stripped into protons just before the target, to overcome space charge issues at injection. As part of the design, we have refined an old proposal to use an RFQ to axially inject bunched $\mathrm{H}_2^+$ ions into the driver cyclotron. This method has several advantages over a classic…
Recently, the use of $\mathrm{H}_2^+$ ions instead of protons to overcome space charge challenges in compact cyclotrons has received much attention. This technique has the potential to increase the available beam current from compact cyclotrons by an order of magnitude, paving the way for applications in energy research, medical isotope production, and particle physics, e.g. a decisive search for sterile neutrinos through the IsoDAR experiment. For IsoDAR we go a step beyond just using $\mathrm{H}_2^+$ and add pre-bunching through a Radio-Frequency Quadrupole (RFQ) embedded in the cyclotron yo…
In the quasi-gasdynamic high-current ion source described in this work, the plasma is sustained by high-power millimeter-wave radiation under the electron cyclotron resonance (ECR) condition. In such facilities, it is possible to achieve high volumetric energy input of up to $250$ $W/cm^3$ and obtain pure proton beams with a minimum amount of impurities and molecular ions. Experiments conducted on the GISMO facility demonstrated the possibility of a proton beam formation with a current of $50$ mA and an extremely high ($99.9$\%) content of atomic ions.
The IsoDAR cyclotron is a 60 MeV cyclotron designed to output 10mA of protons in order to be a driver for a neutrino experiment. Coupling the high flux generated by the IsoDAR system with a kiloton neutrino detector will provide sterile neutrino exclusion searches covering anomalous regions indicated by short baseline experiments. Simultaneously, the coupling of a high power target and kiloton detector allows for the investigation of dark matter candidates, namely axion-like particles. We have shown that nuclear excitations within the IsoDAR target create a unique opportunity to produce axions…
A system for online measurement of the transverse beam emittance was developed. It is named $^{4}$PrOB$\varepsilon$aM (4-Profiler Online Beam Emittance Measurement) and was conceived to measure the emittance in a fast and efficient way using the multiple beam profiler method. The core of the system is constituted by four consecutive UniBEaM profilers, which are based on silica fibers passing across the beam. The $^{4}$PrOB$\varepsilon$aM system was deployed for characterization studies of the 18~MeV proton beam produced by the IBA Cyclone 18 MeV cyclotron at Bern University Hospital (Inselspit…
The performance of the energy degrader in terms of beam properties directly impacts the design and cost of cyclotron-based proton therapy centers. The aim of this study is to evaluate the performances of different existing and novel degrader materials. The quantitative estimate is based on detailed GEANT4 simulations that analyze the beam-matter interaction and provide a determination of the beam emittance increase and transmission. Comparisons between existing (aluminum, graphite, beryllium) and novel (boron carbide and diamond) degrader materials are provided and evaluated against semi-analy…
In a cyclotron-based proton therapy facility, the energy changes are performed by means of a degrader of variable thickness. The interaction of the proton beam with the degrader creates energy tails and increases the beam emittance. A precise model of the degraded beam properties is important not only to better understand the performance of a facility already in operation, but also to support the development of new proton therapy concepts. The exact knowledge of the degraded beam properties, in terms of energy spectrum and transverse phase space, depends on the model used to describe the proto…
Due to its precision and limited side effects, the particle therapy of cancer is gaining popularity. The number of patients treated with protons and light ions reached 150,000 worldwide. There are currently more than 80 facilities, which offer this treatment and several dozen of new ones are in construction. Mostly they are cyclotron-based facilities, which provide proton beams, and only several are synchrotron-based facilities that provide both: proton and carbon-ion beams. The advantage of carbon ions is their higher efficiency in destroying the cancer cells, more localized shape of the Brag…
We have constructed and tested a novel plastic-scintillator-based solid-state active proton target for use in nuclear spectroscopic studies with nuclear reactions induced by an ion beam in inverse kinematics. The active target system, named Stack Structure Solid organic Scintillator Active Target (S4AT), consists of five layers of plastic scintillators, each with a 1-mm thickness. To determine the reaction point in the thickness direction, we exploit the difference in the energy losses due to the beam particle and the charged reaction product(s) in the scintillator material. S4AT offers the pr…