Liquid xenon (LXe) particle detectors are a powerful technology in the field of dark matter direct detection, having shown impressive results in recent years and holding strong possibility for leading the field in sensitivity to galactic weakly interacting massive particles (WIMPs) in the future. The search for WIMPs requires the capability to detect the recoiling nuclei that result when these particles interact with normal matter. In order to make meaningful statements about an observed signal, or lack thereof, the energy scale of recoiling nuclei in LXe must be known. Our understanding of this energy scale is contained in a quantity called the relative scintillation efficiency of nuclear recoils, or L_eff, and has been studied extensively in the literature, producing seemingly contradictory results. I examine all the measurements of L_eff that exist, both direct and indirect, and extract the energy dependent behavior that is statistically consistent globally with all values. Additionally, I examine the measurements covering low energies (>~10 keV, where the largest disagreements exist) and attempt to diagnose the systematic effects that have led to the observed inconsistencies. I show that virtually all major disparity arises due to efficiency roll-off of the detectors at the low energies, and, when taking this into account, find that the observed behavior of L_eff supports a slowly and smoothly decreasing value with decreasing energy. Finally, I discuss the prospects for future measurements, and derive a practical limit to what can be achieved.
NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence readout. Hamamatsu R8520-06SEL photomultipliers are good candidates for the scintillation readout. The performance of this photomultiplier, used as VUV photosensor in a gas proportional scintillation counter, was investigated. Initial results for the detection of primary and secondary scintillation produced as a result of the interaction of 5.9 keV X-rays in …
We provide a new way of constraining the relative scintillation efficiency L_eff for liquid xenon. Using a simple estimate for the electronic and nuclear stopping powers together with an analysis of recombination processes we predict both the ionization and the scintillation yields. Using presently available data for the ionization yield, we can use the correlation between these two quantities to constrain L_eff from below. Moreover, we argue that more reliable data on the ionization yield would allow to verify our assumptions on the atomic cross sections and to predict the value of L_eff. We …
The angular dependence of the columnar recombination in xenon gas, if observed for low energy nuclear tracks, can be used for a direction-sensitive dark matter search. We measured both scintillation and ionization to study columnar recombination for 5.4 MeV alpha particles in a high pressure gas detector filled with 8 atm xenon. Since the recombination photons are emitted several~$μ$s after de-excitation emission, scintillation photons are separated to the fast and slow components. The fast component does not show dependence on the track angle relative to the drift electric field, on the other…
We perform a theoretical study of the scintillation efficiency in the low-energy region crucial for liquid-xenon dark-matter detectors. We develop a computer program to simulate the cascading process of the recoiling xenon nucleus in liquid xenon and calculate the nuclear quenching effect due to atomic collisions. We use the electronic stopping power extrapolated from the experimental data to the low-energy region, and take into account the effects of electrons escaping from the electron-ion pair recombination using the generalized Thomas-Imel model fitted to scintillation data. Our result agr…
Liquid argon (LAr) is a common choice as detection medium in particle physics and rare-event searches. Challenges of LAr scintillation light detection include its short emission wavelength, long scintillation time and short attenuation length. The addition of small amounts of xenon to LAr is known to improve the scintillation and optical properties. We present a characterization campaign on xenon-doped liquid argon (XeDLAr) with target xenon concentrations ranging from 0 to 300 ppm by mass encompassing the measurement of the photoelectron yield $Y$ , effective triplet lifetime $τ_3$ and effect…
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
The scintillation properties of liquid helium upon the recoil of a low energy helium atom are discussed in the context of the possible use of this medium as a detector of dark matter. It is found that the prompt scintillation yield in the range of recoil energies from a few keV to 100 keV is somewhat higher than that obtained by a linear extrapolation from the measured yield for an 5 MeV alpha particle. A comparison is made of both the scintillation yield and the charge separation by an electric field for nuclear recoils and for electrons stopped in helium.
The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio simultaneously to obtain a leakage below that achievable by either discriminant alone. A Monte Carlo is used to show that the dominant fluctuation in the pulse shape quantity is statistical in nature, and project the performance of these techniques in larger detectors. Although the performance is generally weak at low energies relevant to elastic WIMP recoil searche…
We show for the first time that the quenching of electronic excitation from nuclear recoils in liquid xenon is well-described by Lindhard theory, if the nuclear recoil energy is reconstructed using the combined (scintillation and ionization) energy scale proposed by Shutt {\it et al.}. We argue for the adoption of this perspective in favor of the existing preference for reconstructing nuclear recoil energy solely from primary scintillation. We show that signal partitioning into scintillation and ionization is well-described by the Thomas-Imel box model. We discuss the implications for liquid x…
The dependence of the light and charge yield of liquid xenon on the applied electric field and recoil energy is important for dark matter detectors using liquid xenon time projections chambers. Few measurements have been made of this field dependence at recoil energies less than 10 keV. In this paper we present results of such measurements using a specialized detector. Recoil energies are determined via the Compton coincidence technique at four drift fields relevant for liquid xenon dark matter detectors: 0.19, 0.48, 1.02, and 2.32 kV/cm. Mean recoil energies down to 1 keV were measured with u…
As liquid xenon TPCs increase in target mass while pursuing the direct detection of WIMP dark matter, the technical challenges arising due to their size call for new solutions and open the discussion on alternative detector concepts. Proportional scintillation in liquid xenon allows for a single-phase design evading all problems related to the liquid-gas interface and the precise gas gap required in a dual-phase TPC. Aside from a different scintillation mechanism, the successful detection- and analysis scheme of state-of-the-art experiments is maintained in this approach. We study the impact o…
The response of liquid xenon to low-energy electronic recoils is relevant in the search for dark-matter candidates which interact predominantly with atomic electrons in the medium, such as axions or axion-like particles, as opposed to weakly interacting massive particles which are predicted to scatter with atomic nuclei. Recently, liquid-xenon scintillation light has been observed from electronic recoils down to 2.1 keV, but without applied electric fields that are used in most xenon dark matter searches. Applied electric fields can reduce the scintillation yield by hindering the electron-ion …
Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (Leff) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this paper, we present new measurements that extend the energy down to 4 keV, finding that Leff decreases with decreasing energy. We also measure the quenching of scintillation efficiency due to the electric …
A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in liquid xenon at energies below 50 keV, which are relevant for rare event searches using xenon as target material. Here we describe in detail the detector, its associated infrastructure, and the signal identification algorithm developed for processing and analysing the data. We present the first characterisation of the new instrument with calibration data from …
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs γ rays and the energy of the Compton-scattered γ rays was measured with a high-purity germanium (HPGe) detector placed at different scattering angles. The excellent energy resolution of the HPGe detector allows the selection of events with Compton electrons of known energy in the LXe detector. We find that the scintillatio…
The Noble Element Simulation Technique (NEST) is an exhaustive collection of models explaining both the scintillation light and ionization yields of noble elements as a function of particle type (nuclear recoil, electron recoil, alphas), electric field, and incident energy or energy loss dE/dx. It is packaged as C++ code for Geant4 that implements said models, overriding the default model which does not account for certain complexities, such as the reduction in yields for nuclear recoils (NR) compared to electron recoils (ER). We present here improvements to the existing NEST models and update…
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this energy regime a correct treatment of the detector threshold and resolution remains unclear. The energy dependence of the scintillation yield of liquid xenon for nuclear recoils also bears heavily on detector sensitivity, yet numerous measurements have not succeeded in obtaining concordant results. In this article we show that the ratio of detected ionization…
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50 keV. We observe a dependence of the scintillation time distribution and signal yield on the pressure and temperature of the liquid neon.
Taking liquid xenon detectors as a case study, the importance of a robust recoil energy calibration as a prerequisite to a search for light-mass Weakly Interacting Massive Particles (WIMPs) is emphasized. Important shortfalls in the analysis of existing measurements of the relative scintillation efficiency and ionization yield for nuclear recoils in liquid xenon are described, leading to the conclusion that recent attempts to extract light-WIMP sensitivity limits from the XENON10 and XENON100 detectors are premature and overly optimistic.
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on ava…
Neutrinos from supernova (SN) bursts can give rise to detectable number of nuclear recoil (NR) events through the coherent elastic neutrino-nucleus scattering (CE$ν$NS) process in large scale liquid xenon detectors designed for direct dark matter search, depending on the SN progenitor mass and distance. Here we show that in addition to the direct NR events due to CE$ν$NS process, the SN neutrinos can give rise to additional nuclear recoils due to the elastic scattering of neutrons produced through inelastic interaction of the neutrinos with the xenon nuclei. We find that the contribution of th…
Vacuum ultraviolet light emission from xenon-doped liquid argon is described in the context of liquid noble gas particle detectors. Xenon concentrations in liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from the second excimer continuum of argon ($\sim$127 nm) to the second excimer continuum of xenon ($\sim$174 nm) is observed by recording optical emission spectra. The transfer almost saturates at a xenon concentration of $\sim$10 ppm for which, in addition, an intense emission in the infrared at a peak wavelength of 1.17 $μ$m with (13000$\pm$4000) photons per MeV depo…
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the …
Dark matter particles scattering off some target nuclei are expected to deposit very small energies in form of nuclear recoils (below 100 keV). Because of the low scintillation efficiency for nuclear recoils vs. electron recoils, in most of the scintillating targets considered in the search for dark matter, the region below 10 keVee concentrates most of the expected dark matter signal. For this reason, very low energy threshold (at or below 2 keVee) and very low background are required. This is the case of the ANAIS (Annual modulation with NaI Scintillators) experiment. A good knowledge of the…
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding …
The usual nuclear recoil energy reconstruction employed by liquid xenon dark matter search experiments relies only on the primary scintillation photon signal. Energy reconstruction based on both the photon and electron signals yields a more accurate representation of search results. For a dark matter particle mass m~10 GeV, a nuclear recoil from a scattering event is more likely to be observed in the lower left corner of the typical search box, rather than near the nuclear recoil calibration centroid. In this region of the search box, the actual nuclear recoil energies are smaller than the usu…
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two lower fields are in agreement with those from literature; additional measurements at a higher field of 366 V/cm are presented. The electronic and nuclear recoil discrimination as well as its dependence…
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of Kr-83m were both observed. This calibration source will allow the characterization of the scintillation and ionization response of noble liquid detectors at low energies, highly valuable for the search f…
We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields $12.8 \pm 0.3 ~ (11.2 \pm 0.3)~{\rm photoelectron/keV}$ for $511.0$-${\rm keV}$ $γ$-ray events based on a photomultiplier tube single photoelectron response modeling with a Gaussian plus an additional exponential term (with only a Gaussian term). It is exposed to a variety of calibration sources such as $^{22}{\rm Na}$ and $^{241}{\rm Am}$ $γ$-ray emitters, and…
Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination spac…
The bright scintillation of pure CsI operated at liquid-nitrogen temperature makes of this material a promising dark matter and neutrino detector. We present the first measurement of its quenching factor for nuclear recoils. Our findings indicate it is indistinguishable from that for sodium-doped CsI at room temperature. Additional properties such as light yield, afterglow, scintillation decay properties for electron and nuclear recoils, and energy proportionality are studied over the \mbox{108-165 K} temperature range, confirming the vast potential of this medium for rare-event searches.
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surf…