arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0905.1766physics.ins-detastro-ph.IMhep-ex
收藏

用Kr-83 m标定液体氙探测器

Calibration of a Liquid Xenon Detector with Kr-83m

L. W. Kastens, S. B. Cahn, A. Manzur, D. N. McKinsey

摘要:

本文报道了Kr-83 m源的制备及其在标定液体氙探测器中的应用。Kr-83 m原子是由沸石分子筛中捕获的Rb-83原子衰变产生的,然后引入到液体氙中。衰变的Kr-83 m核通过液体氙闪烁被探测到。在Kr-83 m的衰变过程中,分别观测到能量为9.4keV和32.1keV的转换电子。该校准源将允许在低能量下表征稀有液体探测器的闪烁和电离响应,对于寻找WIMP暗物质非常有价值。Kr-83 m也可以用于测量流体动力学,既可以理解基于惰性液体的粒子探测器中的净化,也可以用于超流氦中经典和量子湍流的研究。

英文摘要:

We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of Kr-83m were both observed. This calibration source will allow the characterization of the scintillation and ionization response of noble liquid detectors at low energies, highly valuable for the search for WIMP dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both to understand purification in noble liquid-based particle detectors, as well as for studies of classical and quantum turbulence in superfluid helium.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑