本文报道了用于校准液体氙探测器的中子激活氙的制备。氙亚稳态衰变产生的γ射线,由快中子活化,被检测和测量其活动在一个闪烁探测器。在用Cf-252(4 × 10^5 n/s)源激活天然氙气5天后,测量了来自131 m和129 m亚稳态的164 keV和236 keV的两条伽马射线线的活度,分别为95和130 Bq/kg。我们还观察到35 keV、100 keV和275 keV的另外三条谱线,它们在几天内就会衰减。中子活化后没有观察到长寿命的活动。
英文摘要:
We report the preparation of neutron-activated xenon for the calibration of liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable states, produced by fast neutron activation, were detected and their activities measured in a LXe scintillation detector. Following a five-day activation of natural xenon gas with a Cf-252 (4 x 10^5 n/s) source, the activities of two gamma ray lines at 164 keV and 236 keV, from Xe-131m and Xe-129m metastable states, were measured at about 95 and 130 Bq/kg, respectively. We also observed three additional lines at 35 keV, 100 keV and 275 keV, which decay away within a few days. No long-lifetime activity was observed after the neutron activation.