Irradiation tests performed on the Herschel/Pacs bolometer arrays
B. Horeau, A. Claret, L. Rodriguez, N. Billot, O. Boulade, E. Doumayrou, K. Okumura, J. Le Pennec
备注:
4 pages, 6 figures
发表信息:
PROCEEDINGS OF THE 9th EUROPEAN WORKSHOP ON RADIATION EFFECTS ON COMPONENTS AND SYSTEMS (RADECS 2006 WORKSHOP) - ATHENS, GREECE, 27-29 SEPTEMBER 2006 Session G: Photonics Devices and Integrated Circuits - PG9
A new concept of bolometer arrays is used for the imager of PACS, one of the three instruments aboard the future Herschel space observatory. Within the framework of PACS photometer characterization, irradiation tests were performed on a dedicated bolometer array in order to study long-term and short-term radiation effects. The main objective was to study particles impacts on the detectors applicable to future observations in orbit and possible hard and/or soft curing to restore its performances. Cobalt-60 gamma ray irradiations did not show significant degradation, so we mainly focused on single events effects (SEE). Protons and alphas irradiations were then performed at the Van de Graaf tandem accelerator at the Institut de Physique Nucleaire (IPN, Orsay, France), respectively at 20MeV and 30MeV. Observation showed that the shape of signal perturbations clearly depends on the location of the impacts either on the detector itself or the read-out circuit. Software curing has then to be anticipated in order to deglitch the signal. This test gives also a unique opportunity to measure some parameters of the detector: electrical crosstalk and thermo- electrical time constant. However a detailed bolometer model is necessary to understand the contribution of the thermal response in relation with the electrical response. It will be the second step of our study. Finally the complete radiation evaluation proved that this detector can be used in spatial experiments.
We present the effects of cosmic rays on the detectors onboard the Herschel satellite. We describe in particular the glitches observed on the two types of cryogenic far- infrared bolometer inside the two instruments PACS and SPIRE. The glitch rates are also reported since the launch together with the SREM radiation monitors aboard Herschel and Planck spacecrafts. Both have been injected around the Lagrangian point L2 on May 2009. This allows probing the radiation environment around this orbit. The impacts on the observation are finally summarized.
JScanam is the default map-maker for Herschel/PACS photometer observations. Making use of the redundant information from multiple passages on the sky with different scanning directions, JScanam is able to remove the $1/f$ noise that severely affects PACS far-infrared maps, preserving at the same time point sources and real extended emission. The JScanam pipeline has been designed to run automatically on all kind of maps and astronomical environments, from Galactic star-forming clouds to deep cosmological fields. The results from the JScanam automatic pipeline can be easily inspected and downlo…
The knowledge of the point spread function (PSF) of imaging instruments represents a fundamental requirement for astronomical observations. The Herschel PACS PSFs delivered by the instrument control centre are obtained from observations of the Vesta asteroid, providing a characterisation of the central part therefore excluding fainter features. However, in many cases information on both the core and the wings of the PSFs is needed. With this aim, we combine Vesta and Mars dedicated observations and obtain PACS PSFs with an unprecedented dynamic range $(\sim 10^6)$, at slow and fast scan speeds…
The absolute stability of the PACS bolometer response over the entire mission lifetime without applying any corrections is about 0.5% (standard deviation) or about 8% peak-to-peak. This fantastic stability allows us to calibrate all scientific measurements by a fixed and time-independent response file, without using any information from the PACS internal calibration sources. However, the analysis of calibration block observations revealed clear correlations of the internal source signals with the evaporator temperature and a signal drift during the first half hour after the cooler recycling. T…
Scanamorphos is one of the public softwares available to post-process scan observations performed with the Herschel photometer arrays. This post-processing mainly consists in subtracting the total low-frequency noise (both its thermal and non-thermal components), masking high-frequency artefacts such as cosmic ray hits, and projecting the data onto a map. Although it was developed for Herschel, it is also applicable with minimal adjustment to scan observations made with some other imaging arrays subjected to low-frequency noise, provided they entail sufficient redundancy; it was successfully a…
The Herschel Space Observatory was the fourth cornerstone mission in the European Space Agency (ESA) science programme. It had excellent broad band imaging capabilities in the far-infrared (FIR) and sub-millimetre part of the electromagnetic spectrum. Although the spacecraft finished observing in 2013, it left a large legacy dataset that is far from having been fully explored and still has a great potential for new scientific discoveries. The PACS and SPIRE photometric cameras observed about 8% of the sky in six different wavebands. This document describes the Herschel/PACS Point Source Catalo…
A 3He sorption cooler produced the operational temperature of 285mK for the bolometer arrays of the Photodetector Array Camera and Spectrometer (PACS) instrument of the Herschel Space Observatory. This cooler provided a stable hold time between 60 and 73h, depending on the operational conditions of the instrument. The respective hold time could be determined by a simple functional relation established early on in the mission and reliably applied by the scientific mission planning for the entire mission. After exhaustion of the liquid 3He due to the heat input by the detector arrays, the cooler…
We present a flux calibration scheme for the PACS chopped point-source photometry observing mode based on the photometry of five stellar standard sources. This mode was used for science observations only early in the mission. Later, it was only used for pointing and flux calibration measurements. Its calibration turns this type of observation into fully validated data products in the Herschel Science Archive. Systematic differences in calibration with regard to the principal photometer observation mode, the scan map, are derived and amount to 5-6%. An empirical method to calibrate out an appar…
The boloSource() algorithm is a tool to separate the signal of compact sources from that of the diffuse background in the timeline of far-infrared measurements performed by the PACS camera of the Herschel Space Observatory. An important characteristic and quality indicator of this method is that how well it can reproduce the flux of faint standard stars which have reliable flux estimates. For this propose we selected a few calibrator targets and constructed light curves by extracting point source flux for each repetition of the measurements independently using standard aperture photometry meth…
We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging REceiver (SPIRE) instrument on the Herschel Space Observatory. This includes the equations describing the calibration scheme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to derive flux calibration parameters (for converting from voltage to flux density) for every bolometer in each array, an analysis of the error budget in the flux calibration for the individual bolometers, …
Our aims are to determine flux densities and their photometric accuracy for a set of seventeen stars that range in flux from intermediately bright (<2.5 Jy) to faint (>5 mJy) in the far-infrared (FIR). We also aim to derive signal-to-noise dependence with flux and time, and compare the results with predictions from the Herschel exposure-time calculation tool. The PACS faint star sample has allowed a comprehensive sensitivity assessment of the PACS photometer. Accurate photometry allows us to establish a set of five FIR primary standard candidates, namely alpha Ari, epsilon Lep, omega,Cap, HD41…
We investigate the effect of the "high-pass filter" data reduction technique on the Herschel PACS PSF and noise of the PACS maps at the 70, 100 and 160 um bands and in medium and fast scan speeds. This branch of the PACS Photometer pipeline is the most used for cosmological observations and for point-source observations.The calibration of the flux loss due to the median removal applied by the PACS pipeline (high-pass filter) is done via dedicated simulations obtained by "polluting" real PACS timelines with fake sources at different flux levels. The effect of the data reduction parameter settin…
The future missions for astrophysical studies in the submillimeter region will need detectors with very high sensitivity and large field of view. Bolometer arrays can fulfill these requirements over a very broad band. We describe a technique that enables bolometer arrays that use quarter wave cavities to have a high spectral response over most of the submillimeter band. This technique is based on the addition on the front of the array of an anti-reflecting dielectric layer. The optimum parameters (layer thickness and distance to the array) are determined by a 2D analytic code. This general pri…
This paper provides an overview of the PACS photometer flux calibration concept, in particular for the principal observation mode, the scan map. The absolute flux calibration is tied to the photospheric models of five fiducial stellar standards (alpha Boo, alpha Cet, alpha Tau, beta And, gamma Dra). The data processing steps to arrive at a consistent and homogeneous calibration are outlined. In the current state the relative photometric accuracy is around 2% in all bands. Starting from the present calibration status, the characterization and correction for instrumental effects affecting the re…
The "TNOs are Cool!: A survey of the trans-Neptunian region" is a Herschel Open Time Key Program that aims to characterize planetary bodies at the outskirts of the Solar System using PACS and SPIRE data, mostly taken as scan-maps. In this paper we summarize our PACS data reduction scheme that uses a modified version of the standard pipeline for basic data reduction, optimized for faint, moving targets. Due to the low flux density of our targets the observations are confusion noise limited or at least often affected by bright nearby background sources at 100 and 160\,$μ$m. To overcome these pro…
The CEA/LETI and CEA/SAp started the development of far-infrared filled bolometer arrays for space applications over a decade ago. The unique design of these detectors makes possible the assembling of large focal planes comprising thousands of bolometers running at 300 mK with very low power dissipation. Ten arrays of 16x16 pixels were thoroughly tested on the ground, and integrated in the Herschel/PACS instrument before launch in May 2009. These detectors have been successfully commissioned and are now operating in their nominal environment at the second Lagrangian point of the Earth-Sun syst…
The Ge:Ga detectors used in the PACS spectrograph onboard the Herschel space telescope react to changes of the incident flux with a certain delay. This generates transient effects on the resulting signal which can be important and last for up to an hour. The paper presents a study of the effects of transients on the detected signal and proposes methods to mitigate them especially in the case of the "unchopped" mode. Since transients can arise from a variety of causes, we classified them in three main categories: transients caused by sudden variations of the continuum due to the observational m…
The Herschel Space Observatory of ESA was launched in May 2009 and is in operation since. From its distant orbit around L2 it needs to transmit a huge quantity of information through a very limited bandwidth. This is especially true for the PACS imaging camera which needs to compress its data far more than what can be achieved with lossless compression. This is currently solved by including lossy averaging and rounding steps on board. Recently, a new theory called compressed-sensing emerged from the statistics community. This theory makes use of the sparsity of natural (or astrophysical) image…
We present the COPS-DIGIT-FOOSH (CDF) Herschel spectroscopy data product archive, and related ancillary data products, along with data fidelity assessments, and a user-created archive in collaboration with the Herschel-PACS and SPIRE ICC groups. Our products include datacubes, contour maps, automated line fitting results, and best 1-D spectra products for all protostellar and disk sources observed with PACS in RangeScan mode for two observing programs: the DIGIT Open Time Key Program (KPOT_nevans_1 and SDP_nevans_1; PI: N. Evans), and the FOOSH Open Time Program (OT1_jgreen02_2; PI: J. Green).…
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210μ m wavelength regime. In photometry mode, it simultaneously images two bands, 60-85μ m or 85-125μ\m and 125-210μ m, over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in each ba…
Aims. We aim to determine far-infrared fluxes at 70, 100, and 160$μ$m of the five major Uranus satellites Titania, Oberon, Umbriel, Ariel and Miranda, based on observations with the photometer PACS-P aboard the Herschel Space Observatory. Methods. The bright image of Uranus is subtracted using a scaled Uranus point spread function (PSF) reference established from all maps of each wavelength in an iterative process removing the superimposed moons. Photometry of the satellites is performed by PSF photometry. Thermophysical models of the icy moons are fitted to the photometry of each measurement …
We describe the reduction of data taken with the PACS instrument on board the Herschel Space Observatory in the Science Demonstration Phase of the Herschel-ATLAS (H-ATLAS) survey, specifically data obtained for a 4x4-deg^2 region using Herschel's fast-scan (60 arcsec/s) parallel mode. We describe in detail a pipeline for data reduction using customised procedures within HIPE from data retrieval to the production of science-quality images. We found that the standard procedure for removing Cosmic-Ray glitches also removed parts of bright sources and so implemented an effective two-stage process …