arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1009.0262astro-ph.IM
收藏

H-ATLAS:科学演示阶段的PACS成像

H-ATLAS: PACS imaging for the Science Demonstration Phase

Edo Ibar, R. J. Ivison, A. Cava, G. Rodighiero, S. Buttiglione, P. Temi, D. Frayer, J. Fritz, L. Leeuw, M. Baes, E. Rigby, A. Verma, S. Serjeant, T. Muller, R. … 展开作者

Edo Ibar, R. J. Ivison, A. Cava, G. Rodighiero, S. Buttiglione, P. Temi, D. Frayer, J. Fritz, L. Leeuw, M. Baes, E. Rigby, A. Verma, S. Serjeant, T. Muller, R. Auld, A. Dariush, L. Dunne, S. Eales, S. Maddox, P. Panuzzo, E. Pascale, M. Pohlen, D. Smith, G. de Zotti, M. Vaccari, R. Hopwood, A. Cooray, D. Burgarella, M. Jarvis

摘要:

我们描述了在Herschel-ATLAS(H-ATLAS)巡天的科学演示阶段中,使用赫歇尔空间天文台上的PACS仪器采集的数据的简化,特别是使用Herschel的快速扫描(60 arcsec/s)并行模式获得的4x 4度区域的数据。我们详细描述了一个管道的数据减少HIPE从数据检索到生产科学质量的图像使用定制的程序。我们发现,消除宇宙射线毛刺的标准程序也消除了部分亮源,因此实施了有效的两阶段过程,以最大限度地减少这些问题。使用100和160 um的3.4和2.5弧分矩形波高通滤波器从时间线中去除明显的1/f噪声。经验测量的点扩散函数(PSF)被用来确定包围的能量分数作为孔径大小的函数。对于100-和160-um波段,有效PSF为~9和~13弧秒(FWHM),90%环绕能量半径为13和18弧秒。天体测量精度好到~<2角秒。最终地图中的噪声在相邻像素之间是相关的,并且比发布之前宣传的要高。对于一对交叉扫描,对于100 μ m处的9-13弧秒半径孔径,5-sigma点源灵敏度为125-165 mJy,对于160 μ m处的13-18弧秒半径孔径,5-sigma点源灵敏度为150-240 mJy。

英文摘要:

We describe the reduction of data taken with the PACS instrument on board the Herschel Space Observatory in the Science Demonstration Phase of the Herschel-ATLAS (H-ATLAS) survey, specifically data obtained for a 4x4-deg^2 region using Herschel's fast-scan (60 arcsec/s) parallel mode. We describe in detail a pipeline for data reduction using customised procedures within HIPE from data retrieval to the production of science-quality images. We found that the standard procedure for removing Cosmic-Ray glitches also removed parts of bright sources and so implemented an effective two-stage process to minimise these problems. The pronounced 1/f noise is removed from the timelines using 3.4- and 2.5-arcmin boxcar high-pass filters at 100 and 160-um. Empirical measurements of the point-spread function (PSF) are used to determine the encircled energy fraction as a function of aperture size. For the 100- and 160-um bands, the effective PSFs are ~9 and ~13 arcsec (FWHM), and the 90-per-cent encircled energy radii are 13 and 18 arcsec. Astrometric accuracy is good to ~<2 arcsec. The noise in the final maps is correlated between neighbouring pixels and rather higher than advertised prior to launch. For a pair of cross-scans, the 5-sigma point-source sensitivities are 125-165 mJy for 9-13-arcsec radius apertures at 100-um and 150-240 mJy for 13-18-arcsec radius apertures at 160-um.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑