在线自适应放射治疗(ART)具有很大的希望,可以通过基于当前患者解剖结构的实时治疗适应性来显著降低正常组织毒性和/或改善肿瘤控制。然而,在线ART临床实现的主要技术障碍,即无法实现治疗重新规划的实时效率,尚未得到解决。为了克服这一挑战,本文介绍了我们的工作,实现了调强放射治疗(IMRT)的直接孔径优化(DAO)算法的图形处理器(GPU)的基础上,我们以前的工作在CPU上。我们将DAO问题描述为一个大规模的凸规划问题,并使用一种称为列生成方法的精确方法在GPU上处理其极大的维数。5个9野前列腺和5个5野头颈部IMRT临床病例,5个\times 5 mm 2射束尺寸和2.5 \times 2.5 \times 2.5 mm 3体素尺寸用于评估我们的算法在GPU上。在NVIDIA Tesla C1060 GPU卡上使用50个MLC孔径生成最佳治疗计划仅需0.7~2.5秒。因此,我们的工作解决了一个主要问题,在开发超快速(重新)规划技术的在线艺术。
英文摘要:
Online adaptive radiation therapy (ART) has great promise to significantly reduce normal tissue toxicity and/or improve tumor control through real-time treatment adaptations based on the current patient anatomy. However, the major technical obstacle for clinical realization of online ART, namely the inability to achieve real-time efficiency in treatment re-planning, has yet to be solved. To overcome this challenge, this paper presents our work on the implementation of an intensity modulated radiation therapy (IMRT) direct aperture optimization (DAO) algorithm on graphics processing unit (GPU) based on our previous work on CPU. We formulate the DAO problem as a large-scale convex programming problem, and use an exact method called column generation approach to deal with its extremely large dimensionality on GPU. Five 9-field prostate and five 5-field head-and-neck IMRT clinical cases with 5\times5 mm2 beamlet size and 2.5\times2.5\times2.5 mm3 voxel size were used to evaluate our algorithm on GPU. It takes only 0.7~2.5 seconds for our implementation to generate optimal treatment plans using 50 MLC apertures on an NVIDIA Tesla C1060 GPU card. Our work has therefore solved a major problem in developing ultra-fast (re-)planning technologies for online ART.
Beam modelling of Hitachi PROBEAT proton therapy system for a GPU-based Fast Monte Carlo dose engine
University of Nebraska Omaha(内布拉斯加大学奥马哈分校);Rice University(莱斯大学);The University of Texas MD Anderson Cancer(德克萨斯大学安德森癌症中心);Mevion Medical System(美维医疗系统);Emory University(埃默里大学)
New dosimetry planning strategy based on continuous dose gradient used to reduce dose estimation errors due to respiratory motion in breast radiation therapy
Dose Validation of GRID Block Treatment Applicator within the RayStation Treatment Planning System
University of Rhode Island(罗德岛大学);Mary Bird Perkins Cancer Center(玛丽·伯德·珀金斯癌症中心);Indiana University Medical School(印第安纳大学医学院);Warren Alpert Medical School of Brown University(布朗大学沃伦·阿尔帕特医学院)
An AI dose engine for fast carbon ion treatment planning
GSI Helmholtzzentrum für Schwerionenforschung(德国重离子研究中心);Technische Universität Darmstadt(达姆施塔特工业大学);Sapienza Università di Roma(罗马大学);INFN (Istituto Nazionale di Fisica Nucleare) section of Roma 1(意大利国家核物理研究所罗马第一分部);Delft University of Technology(代尔夫特理工大学);University Federico II(那不勒斯费德里科二世大学)
GPU-accelerated FREDopt package for simultaneous dose and LETd proton radiotherapy plan optimization via superiorization methods
Silesian University of Technology(西里西亚理工大学);Institute of Nuclear Physics PAN(波兰科学院核物理研究所);German Cancer Research Center (DKFZ)(德国癌症研究中心);National Oncology Institute, National Research Institute, Krakow Branch(国家肿瘤研究所克拉科夫分部);Dipartimento di Scienze di Base e Applicate per l'Ingegneria, La Sapienza Università di Roma(罗马大学基础与应用工程科学系);University of Haifa(海法大学);Heidelberg University(海德堡大学)