The LCTPC collaboration is developing a time projection chamber (TPC) for a future linear collider. In the ILD concept for an ILC detector a TPC is foreseen as main tracking device. In order to get measurable signals on the anode, the primary electrons, produced by charged particles traversing the TPC, have to be multiplied. For this purpose gas electron multipliers (GEMs) can be used. Studies of these GEMs are performed at the DESY FLC group and presented in the following.
The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify electron clusters from the primary ionisation is achieved as well as flexibility and large anode coverage. The benefits of this high granularity, in particular for dE/dx measurements, are outlined and the current software and hardware development status towards a proof-of-principle is given.
We present work on the detection of neutral particles via nuclear recoils in gas-filled Time Projection Chambers (TPCs). We employ Gas Electron Multipliers (GEMs) to amplify the signal and silicon pixel electronics to detect the avalanche charge. These technologies allow ionization in the target gas to be detected with low noise, improved position and time resolution, and high efficiency. We review experimental results obtained in previous years, and report on ongoing simulation studies and construction of the first prototype at the University of Hawaii. We also present prospects of using such…
We succeeded in modifying and controlling the electrical resistance of a standard High Pressure Laminate (HPL) panel through the use of a Gas Electron Multiplier (GEM) foil that has been embedded into the bulk of the HPL plate itself. Electrical characterizations were made and preliminary data show that this HPL-GEM embedded system can easily vary its bulk resistance by more than one order of magnitude. Data show that the bulk resistance change is exponential with the applied voltage to the embedded GEM.
Optical effects in Gaseous Electron Multipliers (GEMs)
University of New Mexico(新墨西哥大学);CERN(欧洲核子研究中心);Imperial College London(伦敦帝国理工学院);University of Birmingham(伯明翰大学);STFC Rutherford Appleton Laboratory(英国科学与技术设施委员会卢瑟福阿普尔顿实验室);University of Hamburg(汉堡大学)
The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify electron clusters from the primary ionisation is achieved as well as flexibility and large anode coverage. The benefits of this high granularity, in particular for dE/dx measurements, are outlined and results of a simulation-based performance study are given. The structure of the first prototype board is discussed, including adaptions based on a very preliminary fi…
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development. A single-mask technique overcomes the cumbersome practice of alignment of two masks, which limits the achievable lateral size. The holes obtained with this technique are conical, and have a so-called rim, a small insulating clearance around the hole in t…
The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in large area GEMs have also been addressed. Using the new improvements it was possible to build a prototype triple-GEM detector of ~ 2000 cm2 active area, aimed at an application for the TOTEM T1 upgrade. …
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap for x-rays can be formed. This would eliminate the parallax error in an x-ray diffraction setup, which limits the spatial resolution at wide diffraction angles. The method is inexpensive and flexible towards possible changes in the design. We show advanced plans to make a prototype of an entirely spherical triple-GEM detector, including a spherical readout structure. This detector wi…
The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE TPC. Radiation hardness, ageing resistance and stability against discharges are main criteria for long-term operation of such detectors in high-rate experiments. In particular, discharge is a serious issue as it may cause irreversible damages to the detector as well as the readout electronics. The charge density inside the amplification region is the limiti…
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the li…
We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with ordinary GEM-like detectors with metallic electrodes; however, due to the high resistivity of its electrodes the RETGEM, in contrast to ordinary hole-type detectors, has the advantage of being fully spark protected. We discovered that RETGEMs can operate stably and at high gains in noble gases and in other badly quenched gases, such as mixtures of noble gases w…
We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The effective gain of the thick-foil GEM with a hole pitch of 140 um, a hole diameter of 70 um, and a thickness of 100 um reached a value of 10^4 at an applied voltage of 720 V. The measured effective gain of the thick-foil and fine-pitch GEM (80 um pitch, 40 um diameter, and 100 um thick) was similar to that of the thick-foil GEM. The gain stability was measur…
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. The method is inexpensive and flexible towards possible changes in the design. We show advanced plans to make a prototype of an entirely spherical triple-GEM detec…
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron Multiplier (GEM) foils with a thickness of 100 μm (2-fold thicker than the standard ones) were immersed in a mixture of argon and carbon dioxide (70:30). The charge readout with 2D position determination was done with resistive charge division. Due to their higher thickness with respect to the standard GEMs, the 100 μm thick GEM foils were found to be less p…
A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it can improve on the light collection efficiency, energy threshold and resolution of conventional micropattern gas detectors. This, together with the intrinsic radiopurity of its constituting elements,…
We present discharge probability studies performed with a single Thick Gas Electron Multiplier (THGEM) irradiated with alpha particles in Ar-CO$_2$ and Ne-CO$_2$ mixtures. We observe a clear dependency of the discharge stability on the noble gas and quencher content pointing to lighter gases being more stable against the development of streamer discharges. A detailed comparison of the measurements with Geant4 simulations allowed us to extract the critical charge value leading to the formation of a spark in a THGEM hole, which is found to be within the range of 3-7$\times10^6$ electrons, depend…
A new approach to suppress ion backflow in multi-GEM structures is suggested. In this approach, the potential difference applied across the gap between two adjacent GEMs is reversed compared to the standard configuration. In such a gap structure, called Electric Gate, a signal transfer from the first to second GEM is presumably provided by the small residual field still existing at small gate voltages and connecting the holes of the two GEMs. On the other hand, ion backflow between the GEMs turned out to be substantially reduced. We also consider another configuration, called Photoelectric Gat…
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size information alone, it is not possible to make precise prediction of the gain. We show that the alignment of the photo-masks between the two sides of the GEM foils plays a crucial role. A misalignment of a few…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these applications will be explained in principle and practice. This paper reviews applications in research, beam instrumentation and homeland security. The detectors described measure neutral radiations such as photons, x-rays, gamma rays and neutrons, as well as all kinds of charged radiation. This paper provides an overview of the still expanding range of possibi…
We report on the manufacture of a first batch of approximately 2,000 Gas Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible circuit production line. This process allows low-cost, reproducible fabrication of a high volume of GEMs of dimensions up to 30$\times$30 cm$^{2}$. First tests indicate that the resulting GEMs have optimal properties as radiation detectors. Production techniques and preliminary measurements of GEM performance are described. This now demonstrated industrial capability should help further establish the prominence of micropattern gas detectors in ac…
Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on independent of the rate. The gain uniformity across the GEM is improved. Coating opens the possibility to produce thick GEMs of very high gain.
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in a single- and in two-electrode cascade, respectively. The signal rise time is of a few ns and the counting-rate capability approaches 10 MHz/mm^2 at 10^4 gains. Sub-mm localization precision was demonst…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted leakage currents and spark breakdowns between the electrodes. Accidental spark events in such MGEM don't lead to their failure as far as positive ions quickly move away from the breakdown region by a strong electric field in the gap region. In this work, we present a review of such GEMs. The chambers containing MGEMs (WGEMs) with pin-anodes are proposed as det…