The next generation of radioactive ion beam facilities, which will give experimental access to many exotic nuclei, are presently being developed. At the same time the next generation of high resolution gamma-ray spectrometers, based on gamma-ray tracking, for studying the structure of these exotic nuclei are being developed. One of the main differences in tracking of $γ$ rays versus charged particles is that the gamma rays do not deposit their energy "continuously" in the detector, but in a few discrete steps. Also, in the field of nuclear spectroscopy, the location of the source is mostly well known while the exact interaction position in the detector is the unknown quantity. This makes the challenges of gamma-ray tracking in germanium somewhat different compared to vertexing in silicon detectors. In these proceedings we present the methods for determining the 3D interaction positions in the detector and how these are used to reconstruct the gamma-ray tracks in the AGATA detector array. We also present preliminary simulation results of a proposed in-beam method to measure the interaction position resolution in the germanium detectors.
The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(11B,ng)12C at Ebeam = 19.1 MeV, while gamma-rays between 2 to 9 MeV were produced using an Am-Be-Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%. Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppres…
A software package for modeling segmented High-Purity Segmented Germanium detectors, AGATAGeFEM, is presented. The choices made for geometry implementation and the calculations of the electric and weighting fields are discussed. Models used for charge-carrier velocities are described. Numerical integration of the charge-carrier transport equation is explained. Impact of noise and crosstalk on the achieved position resolution in AGATA detectors are investigated. The results suggest that crosstalk as seen in the AGATA detectors is of minor importance for the position resolution. The sensitivity …
A new package to simulate the formation of electrical pulses in segmented true-coaxial high purity germanium detectors is presented. The computation of the electric field and weighting potentials inside the detector as well as of the trajectories of the charge carriers is described. In addition, the treatment of bandwidth limitations and noise are discussed. Comparison of simulated to measured pulses, obtained from an 18-fold segmented detector operated inside a cryogenic test facility, are presented.
A new method is proposed for the problem of solving chi-square minimization with a positive solution. This method is embodied in an evolution of the popular NNLS algorithm. Its efficiency with respect to residue minimization is illustrated by the improvement it permits on the location of gamma-interactions inside an AGATA HPGe detector.
A p-type HPGe detector has been segmented by cutting, with a diamond saw, and etching six circumferential grooves through the Li-diffused dead layer. The degree of segmentation was tested with the 88 keV gamma rays from a well-collimated source of 109Cd. The fraction of events, recognized as occurring in more than one segment, and rejected from the energy interval 2038 +/- 5 keV, was measured as 0.59.
Detection systems rely more and more on on-line or off-line comparison of detected signals with basis signals in order to determine the characteristics of the impinging particles. Unfortunately, these comparisons are very sensitive to the random time shifts that may alter the signal delivered by the detectors. We present two fast algebraic methods to determine the value of the time shift and to enhance the reliability of the comparison to the basis signals.
Modern coaxial and planar HPGe detectors allow a precise determination of the energies and trajectories of the impinging gamma-rays. This entails the location of the gamma interactions inside the crystal from the shape of the delivered signals. This paper reviews the state of the art of the analysis of the HPGe response function and proposes methods that lead to optimum signal decomposition. The generic matrix method allows fast location of the interactions even when the induced signals strongly overlap.
The gamma-ray tracking technique is one of the highly efficient detection method in experimental nuclear structure physics. On the basis of this method, two gamma-ray tracking arrays, AGATA in Europe and GRETA in the USA, are currently being developed. The interactions of neutrons in these detectors lead to an unwanted background in the gamma-ray spectra. Thus, the interaction points of neutrons in these detectors have to be determined in the gamma-ray tracking process in order to improve photo-peak efficiencies and peak-to-total ratios of the gamma-ray peaks. Therefore, the recoil energy dist…
A fast method to determine the crystallographic axes of segmented true-coaxial high-purity germanium detectors is presented. It is based on the analysis of segment-occupancy patterns obtained by irradiation with radioactive sources. The measured patterns are compared to predictions for different axes orientations. The predictions require a simulation of the trajectories of the charge carriers taking the transverse anisotropy of their drift into account.
Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold segmented high-purity germanium crystals), placed at a distance of 50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment was to study the interaction of neutrons in the segmented high-purity germanium detectors of AGATA and to investigate the possibility to discriminate neutrons and gamma rays with the gamma-ray tracking technique. …
The end point energies of nuclear $β$ decays have been measured with a segmented planar Ge LEPS detector using both singles and coincidence techniques. The $β- γ$ coincidence has been performed with a segmented planar Ge LEPS and a single 10$\%$ HPGe detector. The $γ$ ray and $β$ particle responses of the Segmented planer Ge LEPS detector were studied using monte carlo simulation code GEANT3. The experimentally obtained $β$ spectrum was in reasonably good agreement with the simulation results. The experimental end point energies are determined with substantial accuracy for some of the known $β…
The unprecedented capabilities of state-of-the-art segmented germanium-detector arrays, such as AGATA and GRETA, derive from the possibility of performing pulse-shape analysis. The comparison of the net- and transient-charge signals with databases via grid-search methods allows the identification of the $γ$-ray interaction points within the segment volume. Their precise determination is crucial for the subsequent reconstruction of the $γ$-ray paths within the array via tracking algorithms, and hence the performance of the spectrometer. In this paper the position uncertainty of the deduced inte…
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform exclusive measurements of direct reactions with the radioactive beams from the SPIRAL1 facility. The performance of the set-up is described through its commissioning and two examples of transfer reactio…
The Advanced GAmma Tracking Array (AGATA) multi detector spectrometer will provide precise information for the study of the properties of the exotic nuclear matter (very unbalanced proton (Z) and neutron (N) numbers) along proton- and neutron- drip lines and of super-heavy nuclei. This is done using the latest technology of particle accelerators. The AGATA spectrometer consists of 180 high purity Germanium detectors. Each detector is segmented into 38 segments. The very harsh project requirements are to measure gamma ray energies with very high resolution (< 1x 10 -3) at a high detector counti…
The first true coaxial 18-fold segmented n-type HPGe prototype detector produced by Canberra-France for the GERDA neutrinoless double beta-decay project was tested both at Canberra-France and at the Max-Planck-Institut fuer Physik in Munich. The main characteristics of the detector are given and measurements concerning detector properties are described. A novel method to establish contacts between the crystal and a Kapton cable is presented.
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realization of gamma-ray tracking and AGATA is a resu…
GRETA, the Gamma-Ray Energy Tracking Array, is an array of highly-segmented HPGe detectors designed to track γ-rays emitted in beam-physics experiments. Its high detection efficiency and state-of-the-art position resolution make it well-suited for imaging applications. In this paper, we derive the expressions for locating a photon emission point using Compton imaging. We also include expressions for corresponding uncertainty calculations.
GRETA, the Gamma-Ray Energy Tracking Array, is an array of highly-segmented HPGe detectors designed to track gamma-rays emitted in beam-physics experiments. Its high detection efficiency and state-of-the-art position resolution make it well-suited for imaging applications. In this paper, we use simulated imaging data to illustrate how imaging can be applied to nuclear lifetime measurments. This approach can offer multiple benefits over traditional lifetime techniques such as RDM.
GRETA, the Gamma-Ray Energy Tracking Array, is an array of highly-segmented HPGe detectors designed to track gamma-rays emitted in beam-physics experiments. Its high detection efficiency and state-of-the-art position resolution enable it to reject Compton background and also sequence detected interactions via Compton kinematics. In this paper, we use simulated photon tracks to estimate how well interactions can be sequenced in the GRETA detector. This lays the groundwork for subsequent gamma-ray imaging applications such as nuclear lifetime measurements.
GRETA, the Gamma-Ray Energy Tracking Array, is an array of highly-segmented HPGe detectors designed to track γ-rays emitted in beam-physics experiments. Its high detection efficiency and state-of-the-art position resolution make it well-suited for Compton imaging applications. In this paper, we use simulated imaging data to illustrate how GRETA can be used to locate the emission points of photons produced during beam experiments. This lays the groundwork for nuclear lifetime measurements using Compton imaging.
The stable nucleus $^{15}$N is the mirror of $^{15}$O, the bottleneck in the hydrogen burning CNO cycle. Most of the $^{15}$N level widths below the proton emission threshold are known from just one nuclear resonance fluorescence (NRF) measurement, with limited precision in some cases. A recent experiment with the AGATA demonstrator array determined level lifetimes using the Doppler Shift Attenuation Method (DSAM) in $^{15}$O. As a reference and for testing the method, level lifetimes in $^{15}$N have also been determined in the same experiment. The latest compilation of $^{15}$N level propert…
The performance of the Advanced GAmma Tracking Array (AGATA) at GANIL is discussed, on the basis of the analysis of source and in-beam data taken with up to 30 segmented crystals. Data processing is described in detail. The performance of individual detectors are shown. The efficiency of the individual detectors as well as the efficiency after $γ$-ray tracking are discussed. Recent developments of $γ$-ray tracking are also presented. The experimentally achieved peak-to-total is compared with simulations showing the impact of back-scattered $γ$ rays on the peak-to-total in a $γ$-ray tracking ar…