Muon ionization cooling provides the only practical solution to prepare high-brilliance beams necessary for a neutrino factory or muon collider. The Muon Ionization Cooling Experiment (MICE), under development at the Rutherford Appleton Laboratory, is installing the first set of particle detectors ever built to measure to 0.1% the emittance of a 200 MeV/c or so muon beam in and out of a cooling cell, and thus measure the cooling cell's performance. Two identical "emittometers" (a precise scintillating-fiber tracker in solenoidal magnetic field and a 50 ps time-of-flight station) measure the six phase-space coordinates of each muon. Another TOF plane and two Cherenkov counters assure the purity of the incoming muon beam. A downstream electron/muon calorimeter eliminates contamination from decay electrons.
The Muon Ionization Cooling Experiment (MICE) has measured the evolution of emittance due to ionization energy loss. Muons were focused onto an absorber using a large aperture solenoid. Lithium-hydride and liquid hydrogen- absorbers have been studied. Diagnostic devices were placed upstream and downstream of the focus, enabling the phase- space coordinates of individual muons to be reconstructed. By observing the properties of ensembles of muons, the change in beam emittance was measured. Data taken during 2016 and 2017 are currently under study to evaluate the change in emittance due to the a…
Emittance exchange mediated by wedge absorbers can be used for longitudinal ionization cooling and for final transverse emittance minimization for a muon collider. A wedge absorber within the Muon Ionization Cooling Experiment (MICE) could serve as a demonstration of the type of emittance exchange needed for six-dimensional (6D) cooling, including the configurations needed for muon colliders. Parameters for this test have been explored in simulation and applied to experimental configurations using a wedge-shaped absorber. A polyethylene wedge absorber has been fabricated and placed in MICE and…
Emittance exchange mediated by wedge absorbers is required for longitudinal ionization cooling and for final transverse emittance minimization for a muon collider. A wedge absorber within the MICE beam line could serve as a demonstration of the type of emittance exchange needed for 6-D cooling, including the configurations needed for muon colliders. Parameters for this test are explored in simulation and possible experimental configurations with simulated results are presented.
Wedge absorbers are needed to obtain longitudinal cooling in ionization cooling. They also can be used to obtain emittance exchanges between longitudinal and transverse phase space. There can be large exchanges in emittance, even with single wedges. In the present note we explore the use of wedge absorbers in the MICE experiment to obtain transverse-longitudinal emittance exchanges within present and future operational conditions. The same wedge can be used to explore "direct" and "reverse" emittance exchange dynamics, where direct indicates a configuration that reduces momentum spread and rev…
Muon ionization cooling is the only practical method for preparing high-brilliance beams needed for a neutrino factory or muon collider. The muon ionization cooling experiment (MICE) under development at the Rutherford Appleton Laboratory comprises a dedicated beamline to generate a range of input emittance and momentum, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. A first measurement of emittance is performed in the upstream magnetic spectrometer with a scintillating-fiber tracker. A cooling cell will then follow, alternating energy loss in liquid hydrogen with RF a…
Muon accelerators offer an attractive option for a range of future particle physics experiments. They can enable high energy (TeV+) high energy lepton colliders whilst mitigating the difficulty of synchrotron losses, and can provide intense beams of neutrinos for fundamental physics experiments investigating the physics of flavor. The method of production of muon beams results in high beam emittance which must be reduced for efficient acceleration. Conventional emittance control schemes take too long, given the very short (2.2 microsecond) rest lifetime of the muon. Ionisation cooling offers a…
The International Muon Ionization Cooling Experiment (MICE) is devoted to a study of a muon cooling channel capable of giving the desired performance for a Neutrino Factory. One of the goals is achieving an absolute accuracy of measurements of emittance reduction as high as 0.1%. The paper describes results of a Monte Carlo study on allowed density variations of liquid hydrogen corresponding to the desired accuracy of the measurements.
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling of a muon beam. The demonstration is based on a simplified version of a neutrino factory cooling channel. As the emittance measurement will be done on a particle-by-particle basis, sophisticated beam instrumentation has been developed to measure particle coordinates and timing vs RF. The muon beamline has been characterized and a preliminary measure of the beam emittance, using a particle-by-particle method with only the TOF detector system, has been performed (MICE STEP I)…
The Muon Ionization Cooling Experiment (MICE) at Rutherford Appleton Laboratory has studied ionization cooling of muons. Several million individual muon tracks have been recorded passing through a series of focusing magnets and a liquid hydrogen or lithium hydride absorber in a variety of magnetic configurations. Identification and measurement of muon tracks upstream and downstream of the absorber are used to study the evolution of the 4D emittance. This paper presents and discusses these results.
Muon beams of low emittance provide the basis for the intense, well characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam. MICE was constructed in a series of steps. Data were taken in 2016 and 2017 in the Step~IV configuration which was optimised for studying the properties of liquid hydrogen and lithium hydride. Preliminary results from o…
The Muon Ionization Cooling Experiment (MICE) will demonstrate the feasibility of ionization cooling, the technique by which it is proposed to cool the muon beam at a future neutrino factory or muon collider. The position and momentum reconstruction of individual muons in the MICE trackers allows for the development of alternative figures of merit in addition to beam emittance. Contraction of the phase space volume occupied by a fraction of the sample, or equivalently the increase in phase space density at its core, is an unequivocal cooling signature. Single-particle amplitude and non-paramet…
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cool…
The international Muon Ionization Cooling Experiment (MICE) is being built, at the Rutherford Appleton Laboratory (RAL), to demonstrate the feasibility of ionization cooling of muon beams. This is one of the major technological steps needed in the development of a muon collider and a neutrino factory based on muon decays in a storage ring. MICE will use particle detectors to measure the cooling effect with high precision, achieving a precision on the measurement of emittance of 0.1% or better. The particle i.d. detectors and trackers must work in harsh environmental conditions due to high magn…
Our objective in this paper is to describe an invariant optimality criterion and then apply it to the procedure of emittance measurement in periodic beam transport channels.
Thermal emittance measurements of a CsK2Sb photocathode at several laser wavelengths are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. The thermal emittance is 0.56+/-0.03 mm-mrad/mm(rms) at 532 nm wavelength. The results are compared with a simple photoemission model and found to be in a good agreement.
We introduce and give examples of applications of an optimality criterion which can be used for the design and comparison of multiple beam profile emittance and Twiss parameters measurement sections and which is independent from the position of the reconstruction point.
Parallel slit-slit devices are commonly used to measure the transverse emittance of a particle beam, selecting a portion of the beam with the front slit and measuring the angular distribution with the rear. This paper calculates the effect of finite slit sizes on measured emittance and Twiss functions in the case of Gaussian spatial and angular distributions of the oncoming beam. A formula for recovering the true emittance from the measured values is derived.
We show that properties of the beam position monitor (BPM) system designed for the measurement of transverse and energy beam jitters can be described in terms of the usual accelerator physics concepts of emittance, energy spread, dispersions and betatron functions. Besides that, using the Courant-Snyder quadratic form as error estimator we introduce the scalar objective function which can be used as design criteria of a BPM measurement system with needed properties.
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the two emittance meters. We compare the results from three series of measurements and present the advantages and drawbacks of the two systems. Coupling between phase-space planes, correlations and mitigation of deleterious effects are discussed. The influence of background noise and aberrations of trace-space figures on emittance measurements and RMS calculation…
We present a pepper-pot design in which we address the problem of penetration by high energy particle, deriving analytical expressions and performing GEANT4 simulations for the estimation of the error introduced by a long (thick) pepper-pot. We also show that a careful design allows to measure the emittance of electron beam of several hundred MeV and beyond.
A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement locati…
The pepper-pot method is a popular emittance measurement technique for high intensity beams at low energy such as those generated by photo-injectors. In this paper, the beam dynamics in the space charge dominated regime and analytical design criteria for a mask-based emittance measurement (pepper-pot method) are revisited. A tracking code developed to test the performance of a pepper-pot setup is introduced. Examples of such testing are presented with particle distributions that were generated using PARMELA under different focusing conditions. These distributions were numerically tested agains…
A superconducting radio-frequency (SRF) photo injector is in operation at the electron linac for beams with high brilliance and low emittance (ELBE) radiation center and generates continuous wave (CW) electron beams with high average current and high brightness for user operation since 2018. The speed of emittance measurement at the SRF gun beamline can be increased by improving the slit-scan system, thus the measurement time for one phase space mapping can be shortened from about 15 minutes to 90 seconds. A parallel algorithm and machine learning have been used to reduce the beamlet image noi…
Ultralow emittance ($\leq20$ nm, normalized) electron beams with $10^5$ electrons per bunch are obtained by tightly focusing an ultrafast ($\sim$ 100 fs) laser pulse on the cathode of a 1.6 cell radiofrequency photoinjector. Taking advantage of the small initial longitudinal emittance, a downstream velocity bunching cavity is used to compress the beam to $<10$ fs rms bunch length. The measurement is performed using a thick high voltage deflecting cavity which is shown to be well-suited to measure ultrashort durations of bunching beams, provided that the beam reaches a ballistic longitudinal fo…
In order to investigate and understand the influence of gun design, cathode preparation and operational parameters on the beam quality it is important to have reliable and accurate beam diagnostics available. The focus of this work was thus to employ the available diagnostic beam line of the current gun demonstrator to characterize the transverse phase space of the beam and measure the emittance at various beam settings and operation conditions. Slit mask and solenoid scanning techniques are applied.
We describe a method that uses Optical Transition Radiation (OTR) screens to measure in a single shot the emittance of an electron beam with an energy greater than 100 MeV. Our setup consists of 4 OTR screens located near a beam waist. A fit of the 4 profiles allows the reconstruction of the Twiss parameters and hence a calculation of the beam emittance. This layout has been simulated using Mathematica to study its sensitivity to errors and using Geant4 to include effects due to the scattering of the electrons in the screens. Some assumptions made in this document are conservative to allow for…
Knowledge of the transverse four-dimensional beam rms-parameters is essential for applications that involve lattice elements that couple the two transverse degrees of freedom (planes). Of special interest is the removal of inter-plane correlations to reduce the projected emittances. A dedicated ROtating System for Emittance measurements (ROSE) has been proposed, developed, and successfully commissioned to fully determine the four-dimensional beam matrix. This device has been used at the High Charge injector (HLI) at GSI using a beam line which is composed of a skew quadrupole triplet, a normal…
The wire scanners are used for a measurement of the very small beam size and the emittance in Accelerator Test Facility (ATF). They are installed in the extraction beam line of ATF damping ring. The extracted beam emittance are ex=1.3x10-9 m.rad, ey=1.7x10-11 m.rad with 2x109 electrons/bunch intensity and 1.3GeV energy. The wire scanners scan the beam by a tungsten wire with beam repetition 0.78Hz. The scanning speed is, however, very slow(~500um/sec). Since the extracted beam is quite stable by using the double kicker system, precision of the size measurement is less than 2um for 50 - 150um h…
Precise manipulation of high brightness electron beams requires detailed knowledge of the particle phase space shape and evolution. As ultrafast electron pulses become brighter, new operational regimes become accessible with emittance values in the picometer range, with enormous impact on potential scientific applications. Here we present a new characterization method for such beams and demonstrate experimentally its ability to reconstruct the 4D transverse beam matrix of strongly correlated electron beams with sub-nanometer emittance and sub-micrometer spot size, produced with the HiRES beaml…
The solenoid scan is one of the most common methods for the in-situ measurement of the thermal emittance of a photocathode in an rf photoinjector. The fringe field of the solenoid overlaps with the gun rf field in quite a number of photoinjectors, which makes accurate knowledge of the transfer matrix challenging, thus increases the measurement uncertainty of the thermal emittance. This paper summarizes two methods that have been used to solve the overlap issue and explains their deficiencies. Furthermore, we provide a new method to eliminate the measurement error due to the overlap issue in so…
A dedicated device to fully determine the four-dimensional beam matrix, called ROSE (ROtating System for Emittance measurements) was successfully commissioned. Results obtained with 83Kr13+ at 1.4 MeV/u are reported in Phys. Rev. Accel. Beams 19, 072802 (2016). Coupled moments were determined with an accuracy of about 10%, which is sufficiently low to reliably determine a lattice which could decouple the beam. However, the remaining uncertainty on the corresponding eigen emittances was still considerable high. The present paper reports on improvement of the evaluation procedure which lowers th…
In its normal mode of operation the Argonne Wakefield Accelerator Facility uses a high charge (10-100 nC), short pulse (3-5 psec) drive bunch to excite high-gradient accelerating fields in various slow-wave structures. To generate this bunch, we designed a 1.5 cell, L-band, rf photocathode gun with an emittance compensating solenoid to give optimal performance at high-charge; it has recently completed commissioning. More recently, we have begun to investigate the possibility of using this gun in a high-brightness, low-charge operating mode, with charge equal to approximately 1 nC, for high-pre…
In this article we present results of emittance growth measurements in the Tevatron beams. Several mechanisms leading to transverse and longitudinal diffusions are analyzed and their contributions estimated.
Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for the proposed Linac Coherent Light Source at SLAC. The transverse emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen using the quadrupole scan technique. The emittance was measured to vary from 1 to 3.5 mm-mrad as the charge is increased from 50 to 350 pC using a laser pulse width of 2 ps FWHM. The measurements are in …
Phase-space partitioning offers an attractive path for the precise tailoring of complex dynamical systems. In Beam Physics, the proposed approach involves (i) producing beams with cross-plane correlations to control kinematical invariants known as eigenemittances and (ii) mapping them to invariants of motion associated with given degrees of freedom via a decoupling transformation. Here we report on the direct experimental demonstration of the mapping of eigenemittances to transverse emittances for an electron beam. Measured phase space density confirms the generation of beams with asymmetric t…
Using a particle-in-cell (PIC) code, we investigated the possibilities for emittance growth through the quadrupole magnets of the system used to transport the high-current electron beam from an induction accelerator to the bremsstrahlung converter target used for flash radiography. We found that even highly mismatched beams exhibited little emittance growth (< 6%), which we attribute to softening of their initial hard edge current distributions. We also used this PIC code to evaluate the accuracy of emittance measurements using a solenoid focal scan following the quadrupole magnets. If the bea…
Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this Letter, we report an absolute measurement (no free parameters or calibration) of a small vertical emittance (5--15 nm rms) of a flat beam by this method, under conditions, when it is unresolvable by a conventional synchrotron light beam size monitor.
Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is th…
We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (greater than or equal to 100 pC) beams produced in the DC gun-based Cornell Energy Recovery Linac Photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittance measured at 9-9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These…
In 2008 the Cornell Electron/Positron Storage Ring (CESR) was reconfigured from an electron/positron collider to serve as a testbed for the International Linear Collider (ILC) damping rings. One of the primary goals of the CESR Test Accelerator (CesrTA) project is to develop a fast low-emittance tuning method which scales well to large rings such as the ILC damping rings, and routinely achieves a vertical emittance of order 10 pm at 2.085 GeV. This paper discusses the tuning methods developed at CesrTA to achieve low-emittance conditions. One iteration of beam-based measurement and correction …
We present a non-invasive, resonant cavity based approach to beam emittance measurement of a shot-to-shot non-circular beam pulse of multi-bunches. In a resonant cavity, desired field components can be enhanced up to Q_L_lambda/pi, where Q_L_lambda is the loaded Q of the resonance mode lambda, when the cavity resonant mode matches with the beam operating frequency. In particular, a Quad-cavity, with its quadrupole mode at beam operating frequency, extracts the beam quad-moment exclusively, utilizing the symmetry of the cavity and some simple networks to suppress common modes. Six successive be…
The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an emittance compensation solenoid. This paper shows that the solenoid scan measurement overestimates the thermal emittance in the ordinary measurement configuration due to a weak quadrupole field (present in either the rf gun or gun solenoid) followed by a rotation in the solenoid. This coupled transverse dynamics aberration introduces a correlation between t…
Crossing a horizontal nonlinear resonance is the approach that can be used to split a beam in several beamlets with the goal to perform multi-turn extraction from a circular particle accelerator. Such an approach has been successfully implemented in the CERN Proton Synchrotron and is used routinely for the production of high-intensity proton beams for fixed-target physics at the Super Proton Synchrotron. Recently, thanks to the deployment of diamond detectors, originally installed to monitor the beam losses at extraction, it has been possible to measure the horizontal beam emittance of the spl…
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cathode surface and prevents surface contamination introduced by other techniques, such as polishing with diamond paste or the machining with oil. Both high roughness and surface contamination cause an in…
In future linear colliders the luminosity will depend on maintaining the small emittance aspect ratio delivered by damping rings. Correction of cross-plane coupling can be important in preventing dilution of the beam emittance. In order to minimize the vertical emittance, especially for a flat beam, it is necessary to remove all cross-plane (x-y) correlations. This paper studies emittance measurement and correction for coupled beams in the presence of realistic measurement errors. The results of simulations show that reconstruction of the full 4x4 beam matrix can be misleading in the presence …
We derive a simple relation for estimating the relative emittance growth in x and y due to intrabeam scattering (IBS) in electron storage rings. We show that IBS calculations for the ATF damping ring, when using the formalism of Bjorken-Mtingwa, a modified formalism of Piwinski (where eta squared divided by beta has been replaced by the dispersion invariant), or a simple high-energy approximate formula all give results that agree well. Comparing theory, including the effect of potential well bunch lengthening, with a complete set of ATF steady-state beam size vs. current measurements we find r…
The Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ) is a 100% duty factor (CW) linac that delivers >100 mA of H+ beam at 6.7 MeV. The 8-m-long, 350-MHz RFQ structure accelerates a dc, 75-keV, 110-mA H+ beam from the LEDA injector with >90% transmission. LEDA [1,2] consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW RFQ with associated high-power and low-level rf systems, a short high-energy beam transport (HEBT) and high-power (670-kW CW) beam stop. The beam emittance is inferred from wire scanner measurements of the beam profile at a single location in the H…
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a high quality of the beam after the plasma acceleration. In this letter we present beam-driven plasma wakefield acceleration experiment, where initially preformed high-quality witness beam was accelerate…
I present a scheme to obtain a 2 to 40 GeV low emittance muon beam, not requiring cooling and within today's technological resources, to be used for early commissioning of muon accelerator projects, or alternatively dedicated muon and neutrino parameter measurements. In particular, a muon rate of 5x10^4 mu/s in a normalized transverse emittance of 5 um at 22 GeV, and energy spread of 1 GeV obtained from O(10^11) e+/s on target at 44 GeV. This emittance is below the expected results of advanced emittance cooling techniques for muons produced from protons-on-target, and represents an alternative…
In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emitta…
The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic chopper located in the Booster injection line. This chopper cannot be utilized for MTA beam, and therefore the entire Linac beam pulse is directed into the MTA beamline. Pulse length manipulation is provided by the 750-keV electrostatic chopper at the upstream end of the Linac and, using this device, beam can be delivered from 8 μsec up to the full 50 μsec Lin…
The Muon Ionization Cooling Experiment (MICE) collaboration seeks to demonstrate the feasibility of ionization cooling, the technique by which it is proposed to cool the muon beam at a future neutrino factory or muon collider. The emittance is measured from an ensemble of muons assembled from those that pass through the experiment. A pure muon ensemble is selected using a particle-identification system that can reject efficiently both pions and electrons. The position and momentum of each muon are measured using a high-precision scintillating-fibre tracker in a 4\,T solenoidal magnetic field. …
The beam parameters of complete prototype of the bERLinPro injector that consisted of a lead cathode in an 1.6 cell superconducting cavity were measured. The measurements are discussed in chapter 2 and indicate that the beam emittance is governed by a multitude of contributions from the cathode and the injector. Cathodes for practical use must have a high enough QE to deliver the required current at moderate illumination intensities and be able to sustain the operation for several days. Alkali antimonides are good candidates for this purpose, as discussed in chapter 3.2. The preparation of suc…
Active plasma lenses have the potential to enable broad-ranging applications of plasma-based accelerators owing to their compact design and radially symmetric kT/m-level focusing fields, facilitating beam-quality preservation and compact beam transport. We report on the direct measurement of magnetic field gradients in active plasma lenses and demonstrate their impact on the emittance of a charged particle beam. This is made possible by the use of a well-characterized electron beam with 1.4 mm mrad normalized emittance from a conventional accelerator. Field gradients of up to 823 T/m are inves…