No imaging apparatus can produce perfect images: spatial resolution is limited by the Rayleigh diffraction bound that is a consequence of the imager's finite spatial extent. We show some N-photon strategies that permit resolution of details that are smaller than this bound, attaining either a 1/sqrt(N) enhancement (standard quantum limit) or a 1/N enhancement (Heisenberg limit) over standard techniques. In the incoherent imaging regime, the methods presented are loss resistant, because they can be implemented with classical-state light sources. Our results may be of importance in many applications: microscopy, telescopy, lithography, metrology, etc.
We propose a technique capable of imaging a distinct physical object with sub-Rayleigh resolution in an ordinary far-field imaging setup using single-photon sources and linear optical tools only. We exemplify our method for the case of a rectangular aperture and two or four single-photon emitters obtaining a resolution enhanced by a factor of two or four, respectively.
The Rayleigh diffraction bound sets the minimum separation for two point objects to be distinguishable in a conventional imaging system. We demonstrate resolution enhancement beyond the Rayleigh bound using random scanning of a highly-focused beam and N-photon photodetection implemented with a single-photon avalanche detector array. Experimental results show resolution improvement by a factor ~sqrt(N) beyond the Rayleigh bound, in good agreement with theory.
As the separation between two emitters is decreased below the Rayleigh limit, the information that can be gained about their separation using traditional imaging techniques, photon counting in the image plane, reduces to nil. Assuming the sources are of equal intensity, Rayleigh's "curse" can be alleviated by making phase-sensitive measurements in the image plane. However, with unequal and unknown intensities the curse returns regardless of the measurement, though the ideal scheme would still outperform image plane counting (IPC), i.e., recording intensities on a screen. We analyze the limits …
The manifestation of the wave nature of light through diffraction imposes limits on the resolution of optical imaging. For over a century, the Abbe-Rayleigh criterion has been utilized to assess the spatial resolution limits of optical instruments. Recently, there has been an enormous impetus in overcoming the Abbe-Rayleigh resolution limit by projecting target light beams onto spatial modes. These conventional schemes for superresolution rely on a series of spatial projective measurements to pick up phase information that is used to boost the spatial resolution of optical systems. Unfortunate…
Any imaging device such as a microscope or telescope has a resolution limit, a minimum separation it can resolve between two objects or sources; this limit is typically defined by "Rayleigh's criterion", although in recent years there have been a number of high-profile techniques demonstrating that Rayleigh's limit can be surpassed under particular sets of conditions. Quantum information and quantum metrology have given us new ways to approach measurement ; a new proposal inspired by these ideas has now re-examined the problem of trying to estimate the separation between two poorly resolved po…
Multiparameter estimation theory offers a general framework to explore imaging techniques beyond the Rayleigh limit. While optimal measurements of single parameters characterizing a composite light source are now well understood, simultaneous determination of multiple parameters poses a much greater challenge that in general requires implementation of collective measurements. Here we show, theoretically and experimentally, that Hong-Ou-Mandel interference followed by spatially resolved detection of photons provides precise information on both the separation and the centroid for a pair of point…
We devise a systematic method to determine the Fisher information required for resolving two incoherent point sources with a diffraction-limited linear imaging device. The resulting Cramér-Rao bound gives the lowest variance achievable for an unbiased estimator. When only intensity in the image plane is recorded, this bound diverges as the separation between the sources tends to zero, an effect which has been dubbed as Rayleigh's curse. However, this curse can be lifted using suitable coherent measurements. In particular, we determine a class of measurements that can be easily implemented as p…
Rayleigh's criterion states that it becomes essentially difficult to resolve two incoherent optical point sources separated by a distance below the width of point spread functions (PSF), namely in the subdiffraction limit. Recently, researchers have achieved superresolution for two incoherent point sources with equal strengths using a new type of measurement technique, surpassing Rayleigh's criterion. However, situations where more than two point sources needed to be resolved have not been fully investigated. Here we prove that for any incoherent sources with arbitrary strengths, a one- or two…
Much more image details can be resolved by improving the system's imaging resolution and enhancing the resolution beyond the system's Rayleigh diffraction limit is generally called super-resolution. By combining the sparse prior property of images with the ghost imaging method, we demonstrated experimentally that super-resolution imaging can be nonlocally achieved in the far field even without looking at the object. Physical explanation of super-resolution ghost imaging via compressive sampling and its potential applications are also discussed.
In the last years the possibility of creating and manipulating quantum states of light has paved the way to the development of new technologies exploiting peculiar properties of quantum states, as quantum information, quantum metrology & sensing, quantum imaging ... In particular Quantum Imaging addresses the possibility of overcoming limits of classical optics by using quantum resources as entanglement or sub-poissonian statistics. Albeit quantum imaging is a more recent field than other quantum technologies, e.g. quantum information, it is now substantially mature for application. Several di…
Conventional incoherent imaging based on measuring the spatial intensity distribution in the image plane faces the resolution hurdle described by the Rayleigh diffraction criterion. Here, we demonstrate theoretically using the concept of the Fisher information that quadrature statistics measured by means of array homodyne detection enables estimation of the distance between two incoherent point sources well below the Rayleigh limit for sufficiently high signal-to-noise ratio. This capability is attributed to the availability of spatial coherence information between individual detector pixels a…
Recent work considered the ultimate (quantum) limit of the precision of estimating the distance between two point objects. It was shown that the performance gap between the quantum limit and that of ideal continuum image-plane direct detection is the largest for highly sub-Rayleigh separation of the objects, and that a pre-detection mode sorting could attain the quantum limit. Here we extend this to a more general problem of estimating the length of an incoherently radiating extended (line) object. We find, as expected by the Rayleigh criterion, the Fisher information (FI) per integrated photo…
I propose a quantum imaging method that can beat the Rayleigh-Abbe diffraction limit and achieve de Broglie resolution without requiring a multiphoton absorber as the detector. Using the same non-classical states of light as those for quantum lithography, the proposed method requires only intensity measurements, followed by image post-processing, to produce the same complex image patterns as those in quantum lithography. The method is expected to be experimentally realizable using current technology.
We establish a simple method to assess the quantum Fisher information required for resolving two incoherent point sources with an imaging system. The resulting Cramér-Rao bound shows that the standard Rayleigh limit can be surpassed by suitable coherent measurements. We explicitly find these optimal strategies and present a realization for Gaussian and slit apertures. This involves a projection onto the optimal bases that is accomplished with digital holographic techniques and is compared with a CCD position measurement. Our experimental results unequivocally confirm unprecedented sub-Rayleigh…
It has been recently shown that an interferometric measurement may allow for sub-wavelength resolution of incoherent light. Whereas this holds for noiseless detectors, one could expect that the resolution is in practice limited by signal-to-noise ratio. Here I present an assessment of the ultimate resolution limits that can be achieved using noisy detectors. My analysis indeed indicates that the signal-to-noise ratio represents a fundamental limit to quantum imaging, and the reduced resolution scales with the square root of the signal-to-noise ratio. For example, a signal-to-ratio of $20 dB$ i…
We discuss advantages of using non-classical states of light for two aspects of optical imaging: creating of miniature images on photosensitive substrates, which constitutes the foundation for optical lithography, and imaging of micro objects. In both cases, the classical resolution limit given by the Rayleigh criterion is approximately a half of the optical wavelength. It has been shown, however, that by using multi-photon quantum states of the light field, and multi-photon sensitive material or detector, this limit can be surpassed. We give a rigorous quantum mechanical treatment of this pro…
The Rayleigh limit has so far applied to all microscopy techniques that rely on linear optical interaction and detection in the far field. Here we demonstrate that detecting the light emitted by an object in higher-order transverse electromagnetic modes (TEMs) can help achieving sub-Rayleigh precision for a variety of microscopy-related tasks. Using optical heterodyne detection in TEM01, we measure the position of coherently and incoherently emitting objects to within 0.0015 and 0.012 of the Rayleigh limit, respectively, and determine the distance between two incoherently emitting slits positi…
We report an experimental demonstration of a nonclassical imaging mechanism with super-resolving power beyond the Rayleigh limit. When the classical image is completely blurred out due to the use of a small imaging lens, by taking advantage of the intensity fluctuation correlation of thermal light, the demonstrated camera recovered the image of the resolution testing gauge. This method could be adapted to long distance imaging, such as satellite imaging, which requires large diameter camera lenses to achieve high image resolution.
The distance between two point light sources is difficult to estimate if that distance is below the diffraction (Rayleigh's) resolution limit of the imaging device. A recently proposed technique enhances the precision of this estimation by exploiting the source-separation-dependent coupling of light into higher-order $\rm{TEM}$ modes, particularly the $\rm{TEM}_{01}$ mode of the image. We theoretically analyze the estimation of the source separation by means of homodyne or heterodyne detection with a local oscillator in the $\rm{TEM}_{01}$ mode, which is maximally sensitive to the separation i…
We present a numerical study on the super-resolution of quantum phase sensing and ghost imaging systems operating with multimode N00N states beyond the Rayleigh diffraction limit. Our computational simulations are based on the canonical quantization via numerical mode-decomposition (CQ-NMD) [1,2], in which normal (eigen) modes of electromagnetic fields in inhomogeneous dielectric media are numerically found using computational electromagnetics methods. In the CQ-NMD framework and the Heisenberg picture, the expectation value of arbitrary observables with respect to initial quantum states of va…
Quantum lithography proposes to adopt entangled quantum states in order to increase resolution in interferometry. In the present paper we experimentally demonstrate that the output of a high-gain optical parametric amplifier can be intense yet exhibits quantum features, namely, sub-Rayleigh fringes, as proposed by Agarwal et al. (Phys. Rev. Lett. 86, 1389 (2001)). We investigate multiphoton states generated by a high-gain optical parametric amplifier operating with a quantum vacuum input for a gain values up to 2.5. The visibility has then been increased by means of three-photon absorption. Th…
We obtain the ultimate quantum limit for estimating the transverse separation of two thermal point sources using a given imaging system with limited spatial bandwidth. We show via the quantum Cramér-Rao bound that, contrary to the Rayleigh limit in conventional direct imaging, quantum mechanics does notmandate any loss of precision in estimating even deep sub-Rayleigh separations. We propose two coherent measurement techniques, easily implementable using current linear-optics technology, that approach the quantum limit over an arbitrarily large range of separations. Our bound is valid for arbi…
We investigate theoretically coherent detection implemented simultaneously on a set of mutually orthogonal spatial modes in the image plane as a method to characterize properties of a composite thermal source below the Rayleigh limit. A general relation between the intensity distribution in the source plane and the covariance matrix for the complex field amplitudes measured in the image plane is derived. An algorithm to estimate parameters of a two-dimensional symmetric binary source is devised and verified using Monte Carlo simulations to provide super-resolving capability for high ratio of s…
Quantum lithography achieves phase super-resolution using fragile, experimentally challenging entangled states of light. We propose a scalable scheme for creating features narrower than classically achievable, with reduced use of quantum resources and consequently enhanced resistance to loss. The scheme is an implementation of interferometric lithography using a mixture of an SPDC entangled state with intense classical coherent light. We measure coincidences of up to four photons mimicking multiphoton absorption. The results show a narrowing of the interference fringes of up to 30% with respec…
Optical nanofibers provide a rich platform for exploring atomic and optical phenomena even when they support only a single spatial mode. Nanofibers supporting higher-order modes provide additional degrees of freedom to enable complex evanescent field profiles for interaction with the surrounding medium, but local control of these profiles requires nondestructive evaluation of the propagating fields. Here, we use Rayleigh scattering for rapid measurement of the propagation of light in few-mode optical nanofibers. Imaging the Rayleigh scattered light provides direct visualization of the spatial …
Over the past 20 years, bright sources of entangled photons have led to a renaissance in quantum optical interferometry. Optical interferometry has been used to test the foundations of quantum mechanics and implement some of the novel ideas associated with quantum entanglement such as quantum teleportation, quantum cryptography, quantum lithography, quantum computing logic gates, and quantum metrology. In this paper, we focus on the new ways that have been developed to exploit quantum optical entanglement in quantum metrology to beat the shot-noise limit, which can be used, e.g., in fiber opti…
We determine the ultimate potential of quantum imaging for boosting the resolution of a far-field, diffraction-limited, linear imaging device within the paraxial approximation. First we show that the problem of estimating the separation between two point-like sources is equivalent to the estimation of the loss parameters of two lossy bosonic channels, i.e., the transmissivities of two beam splitters. Using this representation, we establish the ultimate precision bound for resolving two point-like sources in an arbitrary quantum state, with a simple formula for the specific case of two thermal …
The classical bound on image resolution defined by the Rayleigh limit can be beaten by exploiting the properties of quantum mechanical entanglement. If entangled photons are used as signal states, the best possible resolution is instead given by the Heisenberg limit, an improvement proportional to the number of entangled photons in the signal. In this paper we present a novel application of entanglement by showing that the resolution obtained by an imaging system utilizing separable photons can be achieved by an imaging system making use of entangled photons, but with the advantage of a smalle…
We provide a quantitative analysis of super-resolution imaging techniques which exploit temporal fluctuations of luminosity of the sources in order to beat the Rayleigh limit. We define an operationally justified resolution gain figure of merit, that allows us to connect the estimation theory concepts with the ones typically used in the imaging community, and derive fundamental resolution limits that scale at most as the fourth-root of the mean luminosity of the sources. We fine-tune and benchmark the performance of state-of-the-art methods, focusing on the cumulant-based image processing tech…
Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wavefunction. Here, we consider the case in which the light field originates from a bi-photon source, i.e. …
We obtain the multiple-parameter quantum Cramér-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cramér-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear optics…
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated $N$-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of $1/N$. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enh…
A recently identified class of receivers which demultiplex an optical field into a set of orthogonal spatial modes prior to detection can surpass canonical diffraction limits on spatial resolution for simple incoherent imaging tasks. However, these mode-sorting receivers tend to exhibit high sensitivity to contextual nuisance parameters (e.g., the centroid of a clustered or extended object), raising questions on their viability in realistic imaging scenarios where little or no prior information about the scene is available. We propose a multi-stage passive imaging strategy which segments the t…
The wave-particle duality of light introduces two fundamental problems to imaging, namely, the diffraction limit and the photon shot noise. Quantum information theory can tackle them both in one holistic formalism: model the light as a quantum object, consider any quantum measurement, and pick the one that gives the best statistics. While Helstrom pioneered the theory half a century ago and first applied it to incoherent imaging, it was not until recently that the approach offered a genuine surprise on the age-old topic by predicting a new class of superior imaging methods. For the resolution …