arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0708.3716astro-ph
收藏

渗流IGM对类星体HII区红移21 cm观测的影响

The Impact of a Percolating IGM on Redshifted 21 cm Observations of Quasar HII Regions

Paul M. Geil, Stuart Wyithe

摘要:

我们评估了不均匀再电离对使用计划中的低频射电望远镜探测高红移类星体周围HII区域的影响。我们的方法是实现一个半数值方案来计算周围的大质量晕在高红移电离区域的三维结构,包括电离的发光类星体的影响。作为我们的分析的一部分,我们简要地对比我们的计划与出版的半数值模型。我们计算模拟21厘米光谱沿视线对高红移类星体,并估计计划默奇森宽场阵列的能力,以检测HII区域的存在。在再电离过程中,由于类星体的影响变得不那么突出,探测的信噪比会随着特征气泡尺寸的增大而下降。然而,类星体会在观测到的21厘米光谱上留下可探测的特征,这与典型的IGM区域不同。在平均氢中性分数为~30%或更高的时期,我们发现在超过50%的情况下,在100小时的积分内,围绕单个类星体的IGM中的中性气体将是可检测的(在5 σ的意义上)。在超过50%的情况下,需要1000小时的积分才能检测到15%的较小中性分数。一个高度显着的检测将是可能的,在只有100小时的堆栈10个较小的3适当的兆秒差距HII地区。全球平均中性分数()的准确测量<x_HI>将受到单个HII区域的视线之间的系统波动的限制。我们估计的准确性,全球中性分数可以从一个单一的HII区域测量为50%,30%和20%的<x_HI>~ 0.15,0.3和0.5分别。

英文摘要:

We assess the impact of inhomogeneous reionization on detection of HII regions surrounding luminous high redshift quasars using planned low frequency radio telescopes. Our approach is to implement a semi-numerical scheme to calculate the 3-dimensional structure of ionized regions surrounding a massive halo at high redshift, including the ionizing influence of a luminous quasar. As part of our analysis we briefly contrast our scheme with published semi-numerical models. We calculate mock 21cm spectra along the line of sight towards high redshift quasars, and estimate the ability of the planned Murchison Widefield Array to detect the presence of HII regions. The signal-to-noise for detection will drop as the characteristic bubble size grows during reionization because the quasar's influence becomes less prominent. However, quasars will imprint a detectable signature on observed 21cm spectra that is distinct from a region of typical IGM. At epochs where the mean hydrogen neutral fraction is ~30% or greater we find that neutral gas in the IGM surrounding a single quasar will be detectable (at a significance of 5 sigma) within 100 hour integrations in more than 50% of cases. 1000 hour integrations will be required to detect a smaller neutral fraction of 15% in more than 50% of cases. A highly significant detection will be possible in only 100 hours for a stack of 10 smaller 3 proper Mpc HII regions. The accurate measurement of the global average neutral fraction (<x_HI>) will be limited by systematic fluctuations between lines of sight for single HII regions. We estimate the accuracy with which the global neutral fraction could be measured from a single HII region to be 50%, 30% and 20% for <x_HI> ~ 0.15, 0.3 and 0.5 respectively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑