arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0706.3855astro-ph
收藏

哈勃空间望远镜对太阳附近星际^12CO/^13CO的观测

Hubble Space Telescope Survey of Interstellar ^12CO/^13CO in the Solar Neighborhood

Y. Sheffer, M. Rogers, S. R. Federman, D. L. Lambert, R. Gredel

摘要:

我们检查了20条漫反射半透明的银河视线,并从λ/Δ geq为46,000的空间望远镜成像摄谱仪存档数据中检测到的紫外线A-X吸收带中提取了^12CO和^13CO同位素的柱密度。样本中又增加了五个具有戈达德高分辨率摄谱仪数据的目标,这比哈勃太空望远镜观测^13CO的视线数量增加了一倍多。大多数视线的同位素比值为12 ~ 13,与当地的70(^12 C/^13 C)没有显著差异。当地的70是基于对致密分子云中CO和H_2CO发射的旋转谱线的毫米波观测,以及对CH^+的光学测量结果。发现25条视线中的5条朝向较低的12-13值分馏,而样品中的3条视线朝向较高的比率分馏,分别表示同位素电荷交换或选择性光解的优势。^12 CO-/^13 CO比随气体温度或密度等物理条件的变化没有明显的趋势,但^12 CO/^13 CO确实随任一CO同位素物的柱密度以复杂的方式变化,这是由于在CO分馏过程中同位素电荷交换和选择性光解之间的竞争水平不同。最后,H_2的旋转温度表明,所有检测到^13 CO的视线都穿过比不含^13 CO的气体平均冷20 K的气体。这种较冷的气体也被CN和C_2分子取样,后者表明气体动力学温度仅为28 K,足以促进有效的电荷交换反应,从而降低^12 CO/^13 CO的值。

英文摘要:

We examine 20 diffuse and translucent Galactic sight lines and extract the column densities of the ^12CO and ^13CO isotopologues from their ultraviolet A--X absorption bands detected in archival Space Telescope Imaging Spectrograph data with lambda/Deltalambda geq 46,000. Five more targets with Goddard High-Resolution Spectrograph data are added to the sample that more than doubles the number of sight lines with published Hubble Space Telescope observations of ^13CO. Most sight lines have 12-to-13 isotopic ratios that are not significantly different from the local value of 70 for ^12C/^13C, which is based on mm-wave observations of rotational lines in emission from CO and H_2CO inside dense molecular clouds, as well as on results from optical measurements of CH^+. Five of the 25 sight lines are found to be fractionated toward lower 12-to-13 values, while three sight lines in the sample are fractionated toward higher ratios, signaling the predominance of either isotopic charge exchange or selective photodissociation, respectively. There are no obvious trends of the ^12CO-to-^13CO ratio with physical conditions such as gas temperature or density, yet ^12CO/^13CO does vary in a complicated manner with the column density of either CO isotopologue, owing to varying levels of competition between isotopic charge exchange and selective photodissociation in the fractionation of CO. Finally, rotational temperatures of H_2 show that all sight lines with detected amounts of ^13CO pass through gas that is on average colder by 20 K than the gas without ^13CO. This colder gas is also sampled by CN and C_2 molecules, the latter indicating gas kinetic temperatures of only 28 K, enough to facilitate an efficient charge exchange reaction that lowers the value of ^12CO/^13CO.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑