Single-spin detection is one of the important challenges facing the development of several new technologies, e.g. single-spin transistors and solid-state quantum computation. Magnetic resonance force microscopy with a cyclic adiabatic inversion, which utilizes a cantilever oscillations driven by a single spin, is a promising technique to solve this problem. We have studied the quantum dynamics of a single spin interacting with a quasiclassical cantilever. It was found that in a similar fashion to the Stern-Gerlach interferometer the quantum dynamics generates a quantum superposition of two quasiclassical trajectories of the cantilever which are related to the two spin projections on the direction of the effective magnetic field in the rotating reference frame. Our results show that quantum jumps will not prevent a single-spin measurement if the coupling between the cantilever vibrations and the spin is small in comparison with the amplitude of the radio-frequency external field.
We propose a magnetic resonance force microscopy (MRFM)-based nuclear spin quantum computer using tellurium impurities in silicon. This approach to quantum computing combines the well-developed silicon technology with expected advances in MRFM.
We simulate magnetic resonance force microscopy measurements of an entangled spin state. One of the entangled spins drives the resonant cantilever vibrations, while the other remote spin does not interact directly with the quasiclassical cantilever. The Schrödinger cat state of the cantilever reveals two possible outcomes of the measurement for both entangled spins.
We propose a nuclear spin quantum computer based on magnetic resonance force microscopy (MRFM). It is shown that an MRFM single-electron spin measurement provides three essential requirements for quantum computation in solids: (a) preparation of the ground state, (b) one- and two- qubit quantum logic gates, and (c) a measurement of the final state. The proposed quantum computer can operate at temperatures up to 1K.
We consider theoretically the novel technique in magnetic resonance force microscopy which is called ``oscillating cantilever-driven adiabatic reversals''. We present analytical and numerical analysis for the stationary cantilever vibrations in this technique. For reasonable values of parameters we estimate the resonant frequency shift as 6Hz per the Bohr magneton. We analyze also the regime of small oscillations of the paramagnetic moment near the transversal plane and the frequency shift of the damped cantilever vibrations.
We propose a simple model which describes the statistical properties of quantum jumps in a single-spin measurement using the oscillating cantilever-driven adiabatic reversals technique in magnetic resonance force microscopy. Our computer simulations based on this model predict the average time interval between two consecutive quantum jumps and the correlation time to be proportional to the characteristic time of the magnetic noise and inversely proportional to the square of the magnetic noise amplitude.
We consider a simple version of a cyclic adiabatic inversion (CAI) technique in magnetic resonance force microscopy (MRFM). We study the problem: What component of the spin is measured in the CAI MRFM? We show that the non-destructive detection of the cantilever vibrations provides a measurement of the spin component along the effective magnetic field. This result is based on numerical simulations of the Hamiltonian dynamics (the Schrodinger equation) and the numerical solution of the master equation.
New classical modalities of atomic force microscopy continue to emerge to achieve higher spatial, spectral, and temporal resolution for nanometrology of materials. Here, we introduce the concept of a quantum mechanical modality that capitalizes on squeezed states of probe displacement. We show that such squeezing is enabled nanomechanically when the probe enters the van der Waals regime of interaction with a sample. The effect is studied in the non-contact mode, where we consider the parameter domains characterizing the attractive regime of the probe-sample interaction force.
A proposal for a scalable, solid-state implementation of a quantum computer is presented. Qubits are fluorine nuclear spins in a solid crystal of fluorapatite [Ca_5 F(PO_4)_3] with resonant frequencies separated by a large field gradient. Quantum logic is accomplished using nuclear-nuclear dipolar couplings with decoupling and selective recoupling RF pulse sequences. Magnetic resonance force microscopy is used for readout. As many as 300 qubits can be implemented in the laboratory extremes of T=10 mK and B_0=20 T with the existing sensitivity of force microscopy.
We study the effects of wave function collapses in the oscillating cantilever driven adiabatic reversals (OSCAR) magnetic resonance force microscopy (MRFM) technique. The quantum dynamics of the cantilever tip (CT) and the spin is analyzed and simulated taking into account the magnetic noise on the spin. The deviation of the spin from the direction of the effective magnetic field causes a measurable shift of the frequency of the CT oscillations. We show that the experimental study of this shift can reveal the information about the average time interval between the consecutive collapses of the …
The achievement of three-dimensional atomic resolution magnetic resonance microscopy remains one of the main challenges in the visualization of biological molecules. The prospects for single spin microscopy have come tantalizingly close due to the recent developments in sensitive instrumentation. Despite the single spin detection capability in systems of spatially well-isolated spins, the challenge that remains is the creation of conditions in space where only a single spin is resonant and detected in the presence of other spins in its natural dense spin environment. We present a nanomagnetic …
We analyze a single-spin measurement using a transient process in magnetic force microscopy (MFM) which could increase the maximum operating temperature by a factor of Q (the quality factor of the cantilever) in comparison with the static Stern-Gerlach effect. We obtain an exact solution of the master equation, which confirms this result. We also discuss the conditions required to create a macroscopic Schrodinger cat state in the cantilever.
We simulated the quantum dynamics for magnetic resonance force microscopy (MRFM) in the oscillating cantilever-driven adiabatic reversals (OSCAR) technique. We estimated the frequency shift of the cantilever vibrations and demonstrated that this shift causes the formation of a Schrodinger cat state which has some similarities and differences from the conventional MRFM technique which uses cyclic adiabatic reversals of spins. The interaction of the cantilever with the environment is shown to quickly destroy the coherence between the two possible cantilever trajectories. We have shown that using…
A requirement for many quantum computation schemes is the ability to measure single spins. This paper examines one proposed scheme: magnetic resonance force microscopy, including the effects of thermal noise and back-action from monitoring. We derive a simplified equation using the adiabatic approximation, and produce a stochastic pure state unraveling which is useful for numerical simulations.
Measurements of the Casimir force require the elimination of electrostatic interactions between the surfaces. However, due to electrostatic patch potentials, the voltage required to minimize the total force may not be sufficient to completely nullify the electrostatic interaction. Thus, these surface potential variations cause an additional force, which can obscure the Casimir force signal. In this paper, we inspect the spatially varying surface potential (SP) of e-beamed, sputtered, sputtered and annealed, and template stripped gold surfaces with Heterodyne Amplitude Modulated Kelvin Probe Fo…
We have studied theoretically magnetic resonance force microscopy (MRFM) with a high frequency nanomechanical cantilever when the cantilever frequency matches the resonant frequency of a single electron spin. Our estimations show that in this scenario the relative frequency shift of the cantilever can be much greater than the record MRFM frequency shift achieved in experiments with a single spin detection. Experimental realization of our proposal could open the way for fast detection of a single electron spin and even for detection of a single nuclear spin.
Magnetic Resonance Force Microscopy (MRFM) is a powerful technique to detect a small number of spins that relies on force-detection by an ultrasoft magnetically tipped cantilever and selective magnetic resonance manipulation of the spins. MRFM would greatly benefit from ultralow temperature operation, because of lower thermomechanical noise and increased thermal spin polarization. Here, we demonstrate MRFM operation at temperatures as low as 30 mK, thanks to a recently developed SQUID-based cantilever detection technique which avoids cantilever overheating. In our experiment, we detect danglin…
We employ a quantum defect theory framework to provide a detailed analysis of the interplay between a magnetic Feshbach resonance and a shape resonance in cold collisions of ultracold $\rm ^{87}Rb$ atoms as captured in recent experiments using a laser-based collider [Phys. Rev. Research 3, 033209 (2021)]. By exerting control over a parameter space spanned by both collision energy and magnetic field, the width of a Feshbach resonance can be tuned over several orders of magnitude. We apply a quantum defect theory specialized for ultracold atomic collisions to fully describe of the experimental o…
Using atomic force microscopy, we have studied the surface structures of high quality molecular beam epitaxy grown (Ga,Mn)As compound. Several samples with different thickness and Mn concentration, as well as a few (Ga,Mn)(As,P) samples have been investigated. All these samples have shown the presence of periodic ripples aligned along the $[1\bar{1}0]$ direction. From a detailed Fourier analysis we have estimated the period (~50 nm) and the amplitude of these structures.