In the first version of this paper (arXiv: 1003.2899v1, 15.03.2010) there is described first, traditional method of measuring the non-zero shift of interference fringe in the Michelson interferometer, operating on the effects of second order with respect to v/c, and are revealed hidden causes of the failure to measure the shift of interference fringe in the period from 1881 till 1960. It is shown that at the latitude of Obninsk within a 24-hour observation period the horizontal projection of aether wind velocity varies from 140 km/s to 480 km/s. The second version of this paper (arXiv: 1003.2899v2, 15.04.2010) is supplemented with a second method of finding the velocity of the aether wind -- through measuring the largest seasonal decrease in the ratio of the summer shift of the interference fringe to the winter one (equaled ~12%). It gave the same interval of values of the projections of the aether wind velocity as the first method. More than hundred years there persists a belief that Michelson-type interferometer can not be adjusted such as to detect effects of the first order with respect to v/c. Below I show that it is possible, and more successfully than on the interferometer of the second order. In contrast to the traditional approach, in the interferometer of the first order the light after splitting on a semi-transparent plate propagates in both arms to the reflecting mirrors in one optical medium, and returns after reflection from the mirrors through another optical medium. The shift of the interference fringe was found to be proportional to the difference of dielectric permittivities of these media. The horizontal projection of the Earth's velocity relative to luminiferous aether measured by the first order interferometer agrees with that found by the first two methods.
A new heterodyne detection method is suggested for detecting gravitational waves in a Michelson Interferometer. The method is based on interference between phase changes which are induced by a vibrating mirror with phase changes which are due to the gravitational waves. The advantage of using a second order correlation function in the present analysis is discussed.
We examine quantum detection via a Michelson interferometer embedded in a gas with Kerr nonlinearity. This nonlinear interferometer is illuminated by pulses of classical light. This strategy combines the robustness against practical imperfections of classical light with the improvement provided by nonlinear processes. Regarding ultimate quantum limits, we stress that, as a difference with linear schemes, the nonlinearity introduces pulse duration as a new variable into play along with the energy resources.
We propose a possible approach to achieve an 1/N sensitivity of Michelson interferometer by using a properly designed random phase modulation. Different from other approaches, the sensitivity improvement does not depend on increasing optical powers or utilizing the quantum properties of light. Moreover the requirements for optical losses and the quantum efficiencies of photodetection systems might be lower than the quantum approaches and the sensitivity improvement is frequency independent in all detection band.
We investigate that temperature can be measured by a modified Michelson interferometer, where at least one reflected mirror is replaced by a thermalized sample. Both of two mirrors replaced by the corresponding two thermalized samples can help to approximatively improve the resolution of temperature up to twice than only one mirror replaced by a thermalized sample. For further improving the precision, a nonlinear medium can be employed. The Michelson interferometer is embedded in a gas displaying Kerr nonlinearity. We obtain the analytical equations and numerically calculate the precision with…
We experimentally observe the two-photon interference of multimode photon pairs produced by an optical parametric oscillator far below threshold via a michelson interferometer, which shows a multipeaked structure. We find that the correlation function when the interferometer is unbalanced is clearly dependent on the path difference and phase between two interfering beams, but the shape of correlation function in balanced case is independent on the small path difference and phase beside the height. All experimental results are well agreed with the theoretical prediction.
Optical rigidity in aLIGO gravitational-wave detector, operated on dark port regime, is unstable. We show that the same interferometer with excluded symmetric mechanical mode but with unbalanced arms allows to get stable optical spring for antisymmetric mechanical mode. Arm detuning necessary to get stability is shown to be a small one - it corresponds to small power in signal port. We show that stable optical spring may be also obtained in Michelson-Sagnac interferometer with both power and signal recycling mirrors and unbalanced arms.
Twin-Signal-Recycling (TSR) builds on the resonance doublet of two optically coupled cavities and efficiently enhances the sensitivity of an interferometer at a dedicated signal frequency. We report on the first experimental realization of a Twin-Signal-Recycling Michelson interferometer and also its broadband enhancement by squeezed light injection. The complete setup was stably locked and a broadband quantum noise reduction of the interferometers shot noise by a factor of up to 4\,dB was demonstrated. The system was characterized by measuring its quantum noise spectra for several tunings of …
In this paper, we study two-photon interference of broadband chaotic light in a Michelson interferometer with two-photon-absorption detector. The theoretical analysis is based on two-photon interference and Feynman path integral theory. The two-photon coherence matrix is introduced to calculate the second-order interference pattern with polarizations being taken into account. Our study shows that the polarization is another dimension, as well as time and space, to tune the interference pattern in the two-photon interference process. It can act as a switch to manipulate the interference process…
A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of $e^{2r}$, where $r$ is the squeezing parameter [Phys. Rev. A 102,022614 (2020)]. We show that when photon loss and noise in the two arms is asymmetric an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up…
We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely power-recycling, detuned signal-recycling and squeezed field injection. For the first time we experimentally prove the compatibility of especially the latter two. To achieve a broadband non-classical sensitivity improvement we applied a filter cavity for compensation of quadrature rotation. Signal to noise ratio was improved by up to 2.8 dB beyond the coherent state's shot noise. The complete set-up was stably locked for arbitrary times and characterized by injected si…
We demonstrate the applicability of the EPR entanglement squeezing scheme for enhancing the shot-noise-limited sensitivity of a detuned dual-recycled Michelson interferometers. In particular, this scheme is applied to the GEO\,600 interferometer. The effect of losses throughout the interferometer, arm length asymmetries, and imperfect separation of the signal and idler beams are considered.
Nonlinear quantum metrology schemes can lead to faster than Heisenberg limited scalings for the measurement uncertainty. We study a Michelson interferometer embedded in a Kerr medium [Luis and Rivas, Phys. Rev. A 92, 022104 (2015)] that leads to non-linear, intensity dependent phase shifts corresponding to relative changes in the lengths of its two arms. The quantum Cramer-Rao bound on the minimum achievable measurement uncertainties is worked out and the requirements, in practice, to saturate the bound are investigated. The choice of input state of light into the interferometer and the read o…
Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes with high mechanical Q-val…
Magnonics is an emerging field with potential applications in classical and quantum information processing. Freely propagating magnons in two-dimensional media suffer from dispersion, which limits their effective range and fidelity. We show the design of controllable magnonic circuitry, that utilise surface current carrying wires to create magnonic waveguides. We also show the design of a magnonic directional coupler and controllable Michelson interferometer to demonstrate its utility for information processing tasks.
We analyze the radiation pressure induced interaction of mirror motion and light fields in Michelson-type interferometers used for the detection of gravitational waves and for fundamental research in table-top quantum optomechanical experiments, focusing on the asymmetric regime with a (slightly) unbalanced beamsplitter and a (small) offset from the dark port. This regime, as it was shown recently, provides new interesting features, in particular a stable optical spring and optical cooling on cavity resonance. We show that generally the nature of optomechanical coupling in Michelson-type inter…
Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing---conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9\% interference visibility and find evidence for noise reduction based o…
Quantum nonlinear interferometers (QNIs) can measure the infrared physical quantities of a sample by detecting visible photons. A QNI with Michelson geometry based on the spontaneous parametric down-conversion in a second-order nonlinear crystal is studied systematically. A simplified theoretical model of the QNI is presented. The interference visibility, coherence length, equal-inclination interference, and equal-thickness interference for the QNI are demonstrated theoretically and experimentally. As an application example of the QNI, the refractive index and the angle between two surfaces of…
Interferometric gravitational wave detectors are expected to be limited by shot noise at some frequencies. We experimentally demonstrate that a power recycled Michelson with squeezed light injected into the dark port can overcome this limit. An improvement in the signal-to-noise ratio of 2.3dB is measured and locked stably for long periods of time. The configuration, control and signal readout of our experiment are compatible with current gravitational wave detector designs. We consider the application of our system to long baseline interferometer designs such as LIGO.
An extension of the input-output relation for a conventional Michelson interferometric gravitational-wave detector is carried out to treat an arbitrary coherent state for the injected optical beam. This extension is one of necessary researches toward the clarification of the relation between conventional gravitational-wave detectors and a simple model of a gravitational-wave detector inspired by weak-measurements in [A.~Nishizawa, Phys. Rev. A {\bf 92} (2015), 032123.]. The derived input-output relation describes not only a conventional Michelson-interferometric gravitational-wave detector but…
It is shown in the present Letter that the quantum noise due to high laser intensities in Michelson interferometer for gravitational waves detection can be reduced by sending squeezed vacuum states to the 'dark' port of the interferometer. The experimental details of such physical system have been described in a recent article by Barak and Ben-Aryeh (JOSA-B, 25, 361(2008)). In another very recent article by Voronov and Weyrauch (Phys. Rev.A 81, 053816 (2010)) they have followed our methods for treating the same physical system, and have pointed out an error in the sign of one of our expression…
Differing from the traditional method of achieving subwavelength interference, we have demonstrated the two-photon subwavelength interference effect of broadband chaotic light in a polarization-selective Michelson interferometer with an ultrafast two-photon absorption detector the first time, which is achieved by manipulating two-photon probability amplitudes involved in the interference. In theory, the two-photon polarization coherence matrix and probability amplitudes matrix are combined to develop polarized two-photon interference terms, which explains the experimental results well. In orde…
A modified-weak-value-amplification(MWVA) technique of measuring the mirror's velocity based on the Vernier-effect has been proposed. We have demonstrated with sensitivity-enhanced and the higher signal-to-noise ratio(${\rm SNR}$) by using two cascaded Michelson interferometers. These two interferometers are composed of similar optical structures. One interferometer with a fixed mirror acts as a fixed part of the Vernier-scale, while the other with a moving mirror acts as a sliding part of the Vernier-scale for velocity sensing. The envelope of the cascaded interferometers shifts much more tha…
We analyze the dynamic optomechanical back-action in signal-recycled Michelson and Michelson-Sagnac interferometers that are operated off dark port. We show that in this case --- and in contrast to the well-studied canonical form of dynamic back-action on dark port --- optical damping in a Michelson-Sagnac interferometer acquires a non-zero value on cavity resonance, and additional stability/instability regions on either side of the resonance, revealing new regimes of cooling/heating of micromechanical oscillators. In a free-mass Michelson interferometer for a certain region of parameters we p…
It is challenging for observing superbunching effect with true chaotic light, here we propose and demonstrate a method to achieve superbunching effect of the degree of second-order coherence is 2.42 with broadband stationary chaotic light based on a cascaded Michelson interferometer (CMI), exceeding the theoretical upper limit of 2 for the two-photon bunching effect of chaotic light. The superbunching correlation peak is measured with an ultrafast two-photon absorption detector which the full width at half maximum reaches about 95 fs. Two-photon superbunching theory in a CMI is developed to in…
The techniques of power recycling and signal recycling have proven as key concepts to increase the sensitivity of large-scale gravitational wave detectors by independent resonant enhancement of light power and signal sidebands within the interferometer. Developing the latter concept further, twin signal recycling was proposed as an alternative to conventional detuned signal recycling. Twin signal recycling features the narrow-band sensitivity gain of conventional detuned signal recycling but furthermore facilitates the injection of squeezed states of light, increases the detector sensitivity o…
Dissipative optomechanics studies the coupling of the motion of an optical element to the decay rate of a cavity. We propose and theoretically explore a realization of this system in the optical domain, using a combined Michelson--Sagnac interferometer, which enables a strong and tunable dissipative coupling. Quantum interference in such a setup results in the suppression of the lower motional sideband, leading to strongly enhanced cooling in the non-sideband-resolved regime. With state-of-the-art parameters, ground-state cooling and low-power quantum-limited position transduction are both pos…
The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible beam size. In this article we describe the optical design of a 10\,m Fabry-Pérot Michelson interferometer with tunable stability. Our design will allow us to carry out initial commissioning with arm cavi…
We investigate how the temporal coherence interference properties of light in a Michelson-Morley interferometer (MMI), using only a single-photon detector, can be understood in a quantum-optics framework in a straightforward and pedagogical manner. For this purpose we make use of elementary quantum field theory and Glaubers theory for photon detection in order to calculate the expected interference pattern in the MMI. If a thermal reference source is used in the MMI local oscillator port in combination with a thermal source in the signal port, the interference pattern revealed by such an inten…
A Michelson interferometer with noise reduction to sub-shot noise levels is proposed and realized. Multiple measurements of a single signal beam are taken and the quantum property of light plays an essential role in the principle underlying this interferometry. The method makes use of the coherent state of light and requires only a simple modification to the standard Michelson interferometer. The surface fluctuation spectra of liquids are measured using this method down to a few orders of magnitude below the shot noise level. The spectrum derived from hydrodynamical considerations agrees well …
The Michelson interferometer is a cornerstone of experimental physics. Its applications range from providing first impressions of wave interference in educational settings to probing spacetime at minuscule precision scales. Interferometer precision provides a unique view of the fundamental medium of matter and energy, enabling tests for new physics as well as searches for the gravitational wave signatures of distant astrophysical events. Optical interferometers are typically operated by continuously measuring the power at their output port. Signal perturbations then create sideband fields, for…
We propose a new optical configuration for an interferometric gravitational wave detector based on the speedmeter concept using a sloshing cavity. Speedmeters provide an inherently better quantum-noise limited sensitivity at low frequencies than the currently used Michelson interferometers. We show that a practical sloshing cavity can be added relatively simply to an existing dual-recycled Michelson interferometer such as Advanced LIGO.
We observed two-photon phase super-resolution in an unbalanced Michelson interferometer with classical Gaussian laser pulses. Our work is a time-reversed version of a two-photon interference experiment using an unbalanced Michelson interferometer. A measured interferogram exhibits two-photon phase super-resolution with a high visibility of 97.9% \pm 0.4%. Its coherence length is about 22 times longer than that of the input laser pulses. It is a classical analogue to the large difference between the one- and two-photon coherence lengths of entangled photon pairs.
Several relatively small-scale experimental setups aimed on prototyping of future laser gravitational-wave detectors and testing of new methods of quantum measurements with macroscopic mechanical objects, are under development now. In these devices, not devoted directly to the gravitational-wave detection, Mach-Zehnder interferometer with pass-through Fabry-Perot cavities in the arms can be used instead of the standard Michelson/Fabry-Perot one. The advantage of this topology is that it does not contain high-reflectivity end mirrors with multilayer coatings, which Brownian noise could constitu…
We investigate the question whether Michelson type interferometry is possible if the role of the beam splitter is played by a spontaneous process. This question arises from an inspection of trajectories of atoms bouncing inelastically from an evanescent-wave (EW) mirror. Each final velocity can be reached via two possible paths, with a {\it spontaneous} Raman transition occurring either during the ingoing or the outgoing part of the trajectory. At first sight, one might expect that the spontaneous character of the Raman transfer would destroy the coherence and thus the interference. We investi…
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we pr…
We present experimental demonstrations of two-photon interference involving temporally separated photons within two types of interferometers: a Mach-Zehnder interferometer and a polarization-based Michelson interferometer. The two-photon states are probabilistically prepared in a symmetrically superposed state within the two interferometer arms by introducing a large time delay between two input photons; this state is composed of two temporally separated photons, which are in two different or the same spatial modes. We then observe two-photon interference fringes involving both the Hong-Ou-Man…
A theory of position of massive bodies is proposed that results in an observable quantum behavior of geometry at the Planck scale, $t_P$. Departures from classical world lines in flat spacetime are described by Planckian noncommuting operators for position in different directions, as defined by interactions with null waves. The resulting evolution of position wavefunctions in two dimensions displays a new kind of directionally-coherent quantum noise of transverse position. The amplitude of the effect in physical units is predicted with no parameters, by equating the number of degrees of freedo…
We show that a dynamically evolving two-mode Bose-Einstein condensate (TBEC) with an adiabatic, time-varying Raman coupling maps exactly onto a nonlinear Ramsey interferometer that includes a nonlinear medium. Assuming a realistic quantum state for the TBEC, namely the SU(2) coherent spin state, we find that the measurement uncertainty of the ``path-difference'' phase shift scales as the standard quantum limit (1/N^{1/2}) where N is the number of atoms, while that for the interatomic scattering strength scales as 1/N^{7/5}, overcoming the Heisenberg limit of 1/N.
We propose a novel scheme to achieve two-photon super bunching of thermal light through multiple two-photon-path interference, in which two mutually first-order incoherent optical channels are introduced by inserting a modified Michelson interferometer into a traditional two-photon HBT interferometer, and the bunching peak-to-background ratio can reach 3 theoretically. Experimentally, the super bunching peak-to-background ratio was measured to be 2.4, much larger than the ratio 1.7 measured with the same thermal source in a traditional HBT interferometer. The peak-to-background ratio of two-ph…
Bragg interferometers, operating using pseudospin-1/2 systems composed of two momentum states, have become a mature technology for precision measurements. State-of-the-art Bragg interferometers are rapidly surpassing technical limitations and are soon expected to operate near the projection noise limit set by uncorrelated atoms. Despite the use of large numbers of atoms, their operation is governed by single-atom physics. Motivated by recent proposals and demonstrations of Raman gravimeters in cavities, we propose a scheme to squeeze directly on momentum states for surpassing the projection no…
The twin beam vortex interferometer with phase-conjugating mirror is analyzed in rotating reference frame.Circular motion of the interference pattern occurs due to exchange of the angular momenta between photons and interferometer. Using the concept of the $ideal$ phase-conjugating mirror it is shown that motion of the helical interference pattern of the interacting vortex photons with topological charge $\ell$ may be used for the detection of the slow rotations. The higher density of interference fringes may improve the sensitivity by factor containing $2 \ell$ compared to the conventional Mi…