分段反射镜中相位阶跃的光学测量.基本精度极限

Optical measurements of phase steps in segmented mirrors - fundamental precision limits

L. Noethe, H. M. Adorf

摘要:

相位阶跃是由大口径望远镜的分块镜产生的一种重要的波前像差。在闭环校正周期中,必须使用自然参考星以尽可能高的精度测量这些相位阶跃,即使用少量光子。在本文中,经典的Fisher统计信息用于计算Cramer-Rao界限,它确定了精度的限制,其中的台阶的高度可以估计在一个无偏的方式与给定的光子数和一个给定的测量设备。四种类型的测量设备进行了讨论:一个小的圆柱形小透镜覆盖一个子孔径中心的边界,一个修改后的马赫-曾德尔干涉仪,傅科测试,和曲率传感器的夏克-哈特曼传感器。在理想条件下计算所有传感器的Cramer-Rao界限,理想条件是除了光子散粒噪声之外没有额外噪声或干扰的窄带测量。这个极限是比较与最终的量子统计极限的估计这样一个步骤,这是独立的测量设备。对于Shack-Hartmann传感器,宽带测量,有限采样,和干扰,如大气看到和探测器读出噪声的Cramer-Rao界的影响也进行了研究。这里提出的方法可以用来比较各种设备的精度限制,用于测量相位阶跃和优化设备的参数。在理想条件下,夏克-哈特曼和福柯装置几乎达到了量子统计极限,而马赫-曾德尔和曲率装置则需要大约20倍的光子才能达到同样的精度。

英文摘要:

Phase steps are an important type of wavefront aberrations generated by large telescopes with segmented mirrors. In a closed-loop correction cycle these phase steps have to be measured with the highest possible precision using natural reference stars, that is with a small number of photons. In this paper the classical Fisher information of statistics is used for calculating the Cramer-Rao bound, which determines the limit to the precision with which the height of the steps can be estimated in an unbiased fashion with a given number of photons and a given measuring device. Four types of measurement devices are discussed: a Shack-Hartmann sensor with one small cylindrical lenslet covering a sub-aperture centred over a border, a modified Mach-Zehnder interferometer, a Foucault test, and a curvature sensor. The Cramer-Rao bound is calculated for all sensors under ideal conditions, that is narrowband measurements without additional noise or disturbances apart from the photon shot noise. This limit is compared with the ultimate quantum statistical limit for the estimate of such a step which is independent of the measuring device. For the Shack-Hartmann sensor, the effects on the Cramer-Rao bound of broadband measurements, finite sampling, and disturbances such as atmospheric seeing and detector readout noise are also investigated. The methods presented here can be used to compare the precision limits of various devices for measuring phase steps and for optimising the parameters of the devices. Under ideal conditions the Shack-Hartmann and the Foucault devices nearly attain the ultimate quantum statistical limits, whereas the Mach-Zehnder and the curvature devices each require approximately twenty times as many photons in order to reach the same precision.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑